Sharp IV-S30J User Manual page 164

Compact image sensor camera
Table of Contents

Advertisement

Multiple Degree of Match Inspection
12-2 Setting operation
Setting the measurement conditions
How to enter the measurement conditions setting screen
Select "MAIN-COND" -> "OBJECT TYPE COND"
(menu tree)-> "TYPE00" ->"MEA-CND
(CAMERA1)" -> "MEAS(NEW)," in that order.
Then press the SET key to bring up the "MEAS1"
screen.
Move to the "
"MEASUREMENT1" screen and select "MULTI
MATCHES" from the popup menu.
Press the ESC key to return to the "OBJECT TYPE COND" (menu tree) screen, and select the "MEAS
CND" item shown under "MEAS01 (MULTI MATCHES)" to go to the "MEAS CND" screen.
For details, see "Chapter 8: Setting Examples Using the Menu Tree" in the Introduction and
Hardware.
MEAS SELECTION" line on the
SELECT OBJECT TYPE COND
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS0
POSI-CORRECT
MEAS(NEW)
+ +
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/0
OBJ-TYPE SYS.
TYPE(NEW)
=WINDOW SET ESC=BACK SEL=CHNG IMG TRG=POPUP
MEASUREMENT1 SCREEN COND SAVE
1MEAS SELECTION
MULTI MATCHES
=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
12-2
F C1 BRT
1MEAS SELECTION
F C1 BRT
NO
POSI-DEVIATION
CHK-DEG-MATCH
INSPECT-LEAD
MEAS-BIN-AREA
CNT-BIN-OBJ
LABEL-BIN-OBJ
POINT-MEAS
MULTI-POSI
MULTI MATCHES

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents