Rack Mount Instructions; Removing Power To The Receiver; Power; Main Power - Bosch Conettix D6600 Installation And Operation Manual

Communications receiver/gateway
Hide thumbs Also See for Conettix D6600:
Table of Contents

Advertisement

.
10. Turn the D6600 power switch on. The D6100i
starts as soon as you plug in the AC Transformer.
11. Set the calendar and clock to the correct date and
time and program the necessary options.
12. Ensure that the communication formats are
correct by having communicators send test
reports to each line connected to the receiver.
7.2

Rack Mount Instructions

See the specific installation guide supplied with your
product.
Do not connect the D6600/D6100i to an
outlet controlled by a switch.
7.3

Removing Power to the Receiver

1. Remove the battery power connection.
2. Turn off the AC power on the D6600 or unplug
the D6100i AC transformer.
3. Unplug the AC cord from the outlet.
Do not try to restart the D6600/D6100i
with a fully discharged battery.
Reconnect after you apply power. To
prevent deep battery discharge, use a
D135A Low Battery Cutoff Module.
Refer to the D135A Installation Guide
(P/N: 74-06499-000) for more
information.
If programmable Output 1 or 2 is
activated by automation failure, you
cannot clear Output 1 or 2 by pressing
the [ACKNOWLEDGE] key.
Bosch Security Systems, Inc. | 6/09 | 4998122704-06
Conettix D6600/D6100i | Installation and Operation Guide | 8.0 Power
8.0

Power

8.1

Main Power

Refer to Table 12 on page 32 for D6600 and D6100i
main power specifications.
8.2

Standby Power

During a loss of AC power, the receiver automatically
switches to standby power. External batteries or an
uninterruptible power supply (UPS) provides standby
power. As long as there is adequate standby power,
the receiver's operation is not interrupted, even if the
power loss occurs during signal processing. When
power supervision is enabled and a loss of AC power
occurs, the primary reporting devices (such as
printers and computers) show AC FAIL and the
D6600/D6100i power indicator starts blinking. When
AC power restores, the power indicator stops blinking
and reporting devices show AC RESTORE.
8.3

Connecting External Batteries

Use the terminal on the rear panel to connect an
external DC power source. During AC power outages,
the external DC source supplies power to the
receiver. Use a 12 VDC, 7 to 18 Ah lead-acid battery
for external backup power.
Table 5: Battery Voltage Display
Battery Voltage
Above 11.5 V
11.5 V to 10.2 V
Below 10.2 V
Refer to the appropriate Installation
Supplement included with your product
for the specifics of your particular
installation.
Do not connect an external battery
charger to the D6600/D6100i or its
battery.
There is a risk of explosion if the battery
is replaced by an incorrect type.
Dispose of used batteries according to
the instructions.
Display during
AC power
outage
Battery OK
Battery Low
Battery Bad
Display if no
battery when
AC power is
restored
Battery Missing
11