E66
Checks to perform:
Measure between the connector J6-1/J6-2 of
the main circuit board and the appliance body.
(see Fig. 6) Is there any dispersion?
YES
Detach the connector J6 and measure between
the heating element and the earth contact.
(see fig. 15) Is the circuit open?
YES
Check/replace the wiring and repeat the
diagnostic cycle to check for any further alarms.
J14
J5
J4
GND
Fig. 4
2012 SOE/DT-mdm FCPD-dp
Guide to diagnostics of EWM09312 electronic controls

E66: Heating element power supply relay faulty

J13
J8
J7
J11
J10
J6
General earthing
connection
Washing heating
element
!
Check that all the connectors are correctly inserted
Replace the circuit board and repeat the
diagnostic cycle to check for any further
NO
Replace the heating element and repeat
the diagnostic cycle to check for any
NO
If there are burns on the circuit board,
!
51/69
alarms.
further alarms.
Fig. 15
Fig. 6
MAIN CIRCUIT
BOARD
see page 67