E32: The analogue pressure switch causes an error during calibration

E32
(At the start of every cycle, the appliance drains to empty the tub and creates a level 0 to
Checks to perform:
Drain the water from the tub.
Are the pressure switch tube and
pressure chamber unobstructed?
(disconnect the tube and blow into it
to make sure the system is
unobstructed) (fig. 2 and 8)
YES
Check the drain system (filter, drain
pump, drain tube). Is the appliance
draining correctly?
YES
Select a washing cycle. After a few minutes, has the appliance filled
with water and is the motor running?
Fig. 2
2012 SOE/DT-mdm FCPD-dp
Guide to diagnostics of EWM09312 electronic controls
check the calibration of the analogue pressure switch
NO
NO
YES
Appliance ok
!
Check that all the connectors are correctly inserted
Clean/replace the tube and/or the
pressure chamber and repeat the
diagnostic cycle completely to check for
any further alarms.
Repair the
drain circuit.
Y
E
S
Fig. 8
!
29/69
Replace the
analogue
pressure switch
and repeat the
NO
diagnostic cycle
to check for any
further alarms.
If there are burns on the circuit board,
see page 67