Technical Data - Electrolux DC6-8HP m Installation Manual

Drying cabinet
Table of Contents

Advertisement

2.2 Technical data

Capacity:
Drainage capacity:
Electrical connection:
Traditional threaded fuse:
Automatic fuse:
Power:
Hanging length:
Weight:
Sound pressure level:
Average heat emission per drying cycle used
to assess ventilation need**:
* 6 kg dry weight cotton, 50% residual moisture.
** For assistance with dimensioning necessary ventilation needs, contact authorized ventilation technician. For suffi-
cient ventilation all sources introducing heat need to be taken into account plus all other parameters effecting the
ventilation need. Climate zone, building parameters, room size, etc.
Connections
Connection, condensation
Heat pump
Type of refrigerant
Amount of refrigerant
Fluorinated greenhouse gases
This product contains fluorinated greenhouse gases.
GWP: 1774
CO
equivalent: 1.641 t
2
Leak test: 28 bar
Hermetically sealed.
Energy consumption and drying times
Drying of centrifuged laundry **)
Programs:
Energy consumption:
Energy dried water:
Drying time ***):
**) The values may vary depending on:
• speed during spin cycle
• temperature, humidity in the room
• air circulation in the room (supply air, exhaust air)
• settings in the parameter list regarding moisture sensor and time for the SUN program
The values relate to a 6 kg (dry weight) load of cotton with 50% residual moisture.
***) The drying cabinet reconditions 5 minutes after the textiles have dried
Installation manual
A-weighted emission sound pressure level
Plastic hose dim ⌀ 18 mm. 3 m hose included.
kWh / kg of laundry
kg of laundry
g/min*
400V 3N AC 50 Hz
A
A
kW
meters
kg
dB (A)
kW
kg
kWh / liter
minutes
7
6 - 8
50
10 slow-blow
10
2.3
18
189
<55
1.7
R407C
0.925
Normal drying
0.35
0.70
60

Advertisement

Table of Contents
loading

Table of Contents