LHN‑UC15L‑SIP | LHN‑UC15W‑SIP | AMN‑P15‑SIP
2.1.5

Physical reset button

Reference view
Figure 2.4: Physical reset button and LED
Test/Reset button (Figure 2.4, callout 1)
There is a physical button for test and reset purposes. This button will perform different
actions depending on how long you press it:
1.
2.
3.
Indication LED (Figure 2.4, callout 2)
The LED next to the Test/Reset button serves as a time indicator of how long the Test/reset
button is pressed. Once you click the Test/Reset button once, the LED lights up every five
seconds for as long as you keep the button pressed, and once more when you let go of the
button to indicate the reset is applied.
The LED next to the test button flashes slowly (1 Hz) if the test is successful and quickly
(4 Hz) when it is unsuccessful.
Bosch Security Systems B.V.
1
Press and hold for 1 - 5 seconds: the IP Horn loudspeaker will play a default message to
test the loop between the speaker and the microphone. The IP Horn loudspeaker
performs a check that the speaker is operating and therefore the microphone is used.
When the microphone physical switch is On, the tone lasts around 2 seconds; when it is
turned Off, you hear a brief beep (approximately ½ second).
Press and hold for 6 - 10 seconds: the IP address of the IP Horn loudspeaker will reset to
factory default (DHCP);
Press and hold for 11 - 20 seconds: the IP Horn loudspeaker will reset to factory default.