Product Description
10 Operation indicator
Lights up during operation and flashes if there is a fault.
11 Navigation keys (arrow keys)
12 Confirmation Key
Confirming the selected setting or the selected value
13 Quick menu button
14 Back button
Other functions
4
Selection of the desired domestic hot water mode (Standard / Smart). In standard mode, the fill time for the hot
62
Selecting a menu element or entering a value
Invoking the Quick Menu with the following options:
Force DHW
Powerful operation mode
Return to the previous display or to the previous element
Weekly timer
Setting a weekly timer with up to six switching programmes per day (deactivated if the cooling/heating switch is
activated or the Force heater mode is on).
Holiday timer
Setting a holiday period timer to either switch off the system or to reduce the temperature during this period and
thus save energy. The weekly timer can be deactivated during this time, so that it will be restored automatically
upon completion of the holiday timer period.
Quiet timer
Setting up to six programmes for the quiet mode to reduce the sound level for the set duration.
Backup heater for space heating
Enabling of the backup heater for the heating mode
Backup heater for hot water production
Enabling of the backup heater for the domestic hot water mode
Sterilisation
Activation or deactivation of automatic sterilisation. Observe the locally valid laws and provisions when setting the
sterilisation function. If necessary, please contact your authorised installer or service partner.
Domestic hot water mode (DHW)
water tank is shorter, but the energy consumption is lower in Smart mode. Only available if the domestic hot water
tank is activated.
Another option is the selection of the tank sensor to be used (Top / Center). With the top sensor selected, the
process for heating up the tank is retarded so that energy consumption is reduced. Setting should be changed to
Center when the hot water becomes insufficient. Not available for H generation models.
Domestic hot water capacity
Selection of the desired heating capacity (Variable / Standard) for the domestic hot water tank heat-up. In Vari-
able mode, the tank water is heated up fast, then the tank temperature is kept stable with more efficient part-load
operation. In Standard mode, the tank water is heated up uniformly with rated heating capacity. Not available for
H generation models.
Selection of the Temperature Sensor
Selecting between water temperature sensor, room temperature sensor and room thermostat. In the case of room
thermostat, there is another option, to select between external and internal temperature sensor.
Backup heater capacity
Selection of the maximum power setting desired for the electrical heating element for the heating mode; 3 kW /
6 kW / 9 kW (depending on the model concerned)
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022