Settings Of The Serial Interface; Parallel Interface Xlpt - Bosch Rexroth IndraControl VSB 40.1 Project Planning Manual

Control cabinet pc
Hide thumbs Also See for Rexroth IndraControl VSB 40.1:
Table of Contents

Advertisement

DOK-SUPPL*-VSB*40.1***-PR03-EN-P
Rexroth IndraControl VSB 40.1 Control Cabinet PC
7.2.4

Settings of the Serial Interface

Control panel
7.2.5

Parallel Interface XLPT

XLPT1 – parallel interface for print‐
er, scanner, etc.
D-Sub male connector, 9-pin
Transmission rate:
Handshake:
Interrupt (IRQ):
I/O address:
BIOS presetting:
Fig.7-3:
XCOM, serial interface
Fig.7-4:
Pin assignment COM
Depending on the design, the UPS available as accessory this in‐
terface might be needed for the communication with the UPS.
For the settings of the transmission parameters for the serial interfaces, please
refer to the description of the installed operating system (for Windows: Set‐
tings Control panel,...
BIOS
The default BIOS setting of COM (Serial Port A) is AUTO (automatic parameter
assignment). Apply the following settings to assign the parameters directly:
COM = 3F8H
NOTICE
Interrupt (IRQ) and I/O address have to correspond to the settings carried out
in BIOS.
D-Sub female connector, 25-pin
Type:
Cable length:
Cable type:
Bosch Rexroth AG
Max. 115200 bits/s
Hardware and software handshake (XON, XOFF)
4
AUTO (or 3F8H)
Enabled
Possible malfunctions if IRQ and I/O address‐
es deviate from the BIOS settings.
SPP (ex works), EPP, ECP
3 m max.
Shielded, cross-section min. 0.14 mm
41/83
PC Box