Bosch Rexroth Hagglunds DUc MS2 Installation & Maintenance Manual page 57

Drive unit
Table of Contents

Advertisement

Table 19: Oil volume in tank
Volume
Tank
US
litre
model
gallon
130
130
34.3
220
220
58.1
300
300
79.2
350
350
92.4
400
400
105.7
600
600
158.6
700
700
184.9
900
900
237.8
Volume
Tank
US
litre
model
gallon
130
110
29.0
220
175
46.2
300
245
64.7
350
290
76.6
400
280
74.0
600
420
111.0
700
520
137.4
900
700
184.9
Nominal level
Distance from top
Signal
mm
in
mA
85
3.35
16.9
95
3.74
17.5
80
3.15
18.0
125
4.92
16.3
87
3.43
17.8
82
3.23
18.0
83
3.27
18.8
83
3.27
18.8
Warning level
Distance from top
Signal
mm
in
mA
175
6.89
11.7
299
11.77
9.5
230
9.06
12.2
289
11.38
9.9
270
10.63
10.6
357
14.06
7.2
358
14.09
12.6
388
15.28
11.9
Visual
level gauge
Fig. 53: Point of measure
Commissioning | Hägglunds DUc Drive unit
Volume
US
litre
gallon
137
36.1
234
61.8
318
84.0
385
101.7
425
112.3
625
165.1
715
188.9
915
241.7
Alarm (Stop) level
Volume
US
litre
gallon
90
23.7
160
42.2
223
58.9
260
68.6
260
68.6
390
103.0
490
129.4
650
171.7
RE 15326-WA, Version 06.2020, Bosch Rexroth AB
57/88
Max level
Distance from top
Signal
mm
in
mA
53
2,09
18.7
50
1.97
19.2
39
1.54
19.6
57
2.24
19.0
49
1.93
19.3
44
1.73
19.5
60
2.36
19.3
60
2.36
19.3
Distance from top
Signal
mm
in
mA
266
10.47
6.5
637
25.08
6.8
290
11.42
9.8
371
14.61
6.7
300
11.81
9.4
403
15.87
5.5
404
15.91
11.6
465
18.31
10.2
DD00098816
Point of
measure