Hydraulic Connections - Bosch Rexroth Hagglunds DUc MS2 Installation & Maintenance Manual

Drive unit
Table of Contents

Advertisement

DD00102135
Fig. 23: Connections DUc MS2, MT2
DD00102142
Fig. 24: Connections DUc LS2, LT2

7.6 Hydraulic connections

During mounting of the hydraulic connections the following points must be
followed.
• Do not remove coupling protections until final assembly.
• Mount all external pipes to give sufficient working space to allow maintenance of
the Drive Unit.
• Always use hoses to connect with piping.
• All measures in the hydraulic system must be performed by professional service
personnel with knowledge of risks involved. Be especially accurate when
connecting the A- and B- connections (high pressure).
Pressurized oil leakage
Danger to life or risk of injury.
▶ Do not open any connections if the hydraulic system is pressurized.
Installation | Hägglunds DUc Drive unit
DANGER
RE 15326-WA, Version 06.2020, Bosch Rexroth AB