54
en | RADION TriTech
The vertical adjusting screw must be securely tightened after
setting the angle.
6.2
Sensitivity settings
Standard sensitivity
Use this setting when pets are present in the monitored area.
Standard sensitivity provides excellent detection performance
and is the least sensitive to false alarms.
Intermediate sensitivity
Only use this setting in non-pet installations with minimal
environmental disturbances. Intermediate sensitivity provides
the highest level of detection performance.
6.3
Walk testing
Notice!
To maximize battery life, the LED elements do not activate
unless the unit is in the Walk Test mode.
Perform a walk test to determine the boundaries of the coverage
area. Perform this test at the time of installation and monthly
thereafter. To ensure continual daily operation, instruct the end
user to walk through the far end of the coverage pattern. This
ensures an alarm output prior to arming the system.
Start Walk Test mode from the detector. Insert a slotted
screwdriver to open the detector cover and then close the
detector cover to start a 90-sec Walk Test mode.
Notice!
In the normal operating mode, an alarm can be transmitted only
after three (3) minutes have passed since the previous alarm
restoral. This 3 minute lockout time reduces unnecessary RF
transmissions in high traffic areas, thereby extending battery
life.
2020.05 | 13 | F.01U.261.834
RADION receiver SD
Bosch Security Systems B.V.