Operating Instructions
6.3
External I/O
If you connect external devices such as sensors to the External I/O, and image
buffer/transfer by alarm signal is set, the camera image is transferred by alarm
detection.
Explanation of the External I/O
Pin
G
1
G
2
3
4
Note
•
The External I/O (Input/Output) are independent. Output terminal is controlled
only by External Output Control page on page 152.
164
GND pin
External Sensor Input 1
•
Use it by opening or GND short-circuit.
GND pin
External Sensor Input 2
•
Use it by opening or GND short-circuit.
External Device Control Output
•
You can control this on the External Output page (see page
152).
•
It is an open collector circuit, and the maximum drawing-in
current is the same as pin 4. Do not exceed the voltage of DC
power output terminal (pin 4).
DC Power Output Terminal
•
10.5—13.5 V DC
•
A maximum of 100 mA load drive is possible.