82
en | Maintenance and troubleshooting
Flash pattern
Flashes once every 1 sec
3 quick flashes
Off
Tab. 11.8: Cellular module diagnostic LED patterns
SYSTEM TROUBLE LED patterns
Flash pattern
Flashing
Flashing
Flashing
Flashing
On Steady
Tab. 11.9: SYSTEM TROUBLE LED descriptions
2017.11 | 05 | F.01U.311.207
Off
Installation and Operation Manual
Conettix Universal Dual Path Communicator
Function
Normal state. Indicates normal operation.
Communication error state. Indicates the
module is unable to communicate on the
cellular network.
LED trouble state. Module is not powered, or
some other trouble condition prohibits the
module from controlling the heartbeat LED.
Function
Indicates normal operations.
Indicates Ethernet communication errors. Refer to
SYSTEM TROUBLE Flashing (one flash) - Ethernet table
for more information.
Indicates cellular communication errors. Refer to
SYSTEM TROUBLE Flashing (two flashes) - Cellular
table for more information.
Indicates a communication trouble or failure. Verify IP
address and port numbers entered in the central
station receiver. Make sure the account is enabled in
the receiver. Make sure there is no IP network IP
problem preventing the B465 from reaching the
receiver.
Indicates multiple communication errors. Check the
B465 USB status menu for additional information to
help correct the problem.
Indicates all non IP communication troubles. For
example low, or missing battery, phone lines are off the
hook for more than 2 minutes, or there is a
configuration issue.