2.4
Specifications
TDS 300 programmer
Power consumption
Enclosure rating
Supply voltage
Operating current
Maximum power consumption
Sensing range
Permissible ambient temperature
Collector temperature sensor
Cylinder temperature sensor
Dimensions H x W x D
Tab. 1
Specifications
Temperature sensor S1 (S5 with 2 arrays)
NTC 20K
T ( °C)
R (k Ω)
-20
198.4
-10
112.4
0
66.05
10
40.03
20
25.03
30
16.09
40
10.61
50
7.116
Tab. 2
Resistances of the temperature sensors
The temperature sensors must be disconnected from the programmer for their
resistances to be measured.
T ( °C)
R (k Ω)
60
4.943
70
3.478
80
2.492
90
1.816
100
1.344
110
1.009
120
0.767
130
0.591
6 720 644 593 (2010/04)
1.8 W
IP20 / DIN 40050
230 V AC, 50 Hz
I
: 5 A
max
5 A (max. 1.1 A per output/1 device per output)
- 30 to + 180 °C
0 to + 50 °C
NTC 20K with 2.5m cable
NTC 10K with 3m cable
170 x 190 x 53 mm
Temperature sensor S2 ... S8 NTC 10K
T ( °C)
R (k Ω)
0
35.975
10
22.763
20
14.772
30
9.786
40
6.653
50
4.608
DETAILS OF THE PRODUCT
T ( °C)
R (k Ω)
60
3.243
70
2.332
80
1.704
90
1.262
100
0.95
110
120
125
9