ELECTRICAL CONNECTIONS (FOR ENGINEERS ONLY)
5.4.13 Configuration diagram 1-CD p-p - solar water heating with swimming pool and external heat
exchanger with 2nd pump
L
N R1 N1 R2 N2 R3 R3 R4 R4 R5 R5
230V
R1
AC
WMZ
S8
Fig. 25
R1
Pump SP, solar circulation system
R2
Pump PD, heat exchanger
R3
Pump PE, thermal disinfection (option)
R4
Pump PC, 2nd heat consumer
R5
Valve DWUD, anti-icing system (option)
S1
Temperature sensor (T1), collector FSK
S2
Solar cylinder bottom temperature sensor (T2)
S3
Swimming pool temperature sensor
S4
Solar cylinder middle temperature sensor (option)
S6
Temperature sensor (TD), external heat exchanger
S7
Flow heat meter WMZ temperature sensor (option)
S8
Return heat meter WMZ temperature sensor (option)
WMZ Heat meter (option)
34
L3 N3 L4 N4 L5 N5
R2
R3
R4
S1
S7
R1
S6
R4
R5
S1 S2 S3 S4 S5 S6 S7 S8 I9
R5
S1 S2 S3 S4
S4
S2
S3
R2
6 720 644 593 (2010/04)
S6 S7 S8 WMZ
R3
7747006072-31.1 SD