ELECTRICAL CONNECTIONS (FOR ENGINEERS ONLY)
5.4.17 Configuration diagram 1-ACD p-v - solar water heating with 2nd collector array, swimming
pool (connected via valve) and external heat exchanger
L
N R1 N1 R2 N2 R3 R3 R4 R4 R5 R5
230V
R1
AC
S1
R1
WMZ
S8
Fig. 29
R1
Pump SP, solar circulation system
R2
Pump PD, heat exchanger
R3
Pump PA, 2nd collector array
R4
Valve DWUC for cylinder selection
R5
Valve DWUD, anti-icing system (option)
S1
Temperature sensor (T1), collector FSK, array 1
S2
Solar cylinder bottom temperature sensor (T2)
S3
Swimming pool temperature sensor
S4
Solar cylinder middle temperature sensor (option)
S5
Temperature sensor (TA), collector FSK, array 2
S6
Temperature sensor (TD), external heat exchanger
S7
Flow heat meter WMZ temperature sensor (option)
S8
Return heat meter WMZ temperature sensor (option)
WMZ Heat meter (option)
38
L3 N3 L4 N4 L5 N5
R2
R3
R4
5
S5
S7
R3
R4
S1 S2 S3 S4 S5 S6 S7 S8 I9
R5
S1 S2 S3 S4 S5 S6 S7 S8 WMZ
S4
S2
S6
S3
R5
R2
6 720 644 593 (2010/04)