13-11 Comparator Operator
Array [4]
[0]
Less Than <
*
Approximately equals
[1]
4
[2]
Greater Than >
13-12 Comparator Value
Array [4]
*
0.0
[-9999 - 9999]
4.10.4. 13-2* Timers
Use the timer results to define an event (par. 13-51) or as boolean input in a logic rule (par. 13-40, 13-42 or 13-44).
When timer value has elapsed timer changes state from False to True.
13-20 Logic Controller Controller Timer
Array [3]
*
0.0 s
[0.0 - 3600 s]
4.10.5. 13-4* Logic Rules
Combine up to three boolean inputs (TRUE / FALSE inputs) from timers, comparators, digital inputs, status bits and events using the logical operators AND, OR,
and NOT. Select boolean inputs for the calculation in par. 13-40, 13-42, and 13-44. Define the operators used to logically combine the selected inputs in par. 13-41
and 13-43.
Priority of calculation
The results of par. 13-40, 13-41, and 13-42 are calculated first. The outcome (TRUE / FALSE) of this calculation is combined with the settings of par. 13-43 and
13-44, yielding the final result (TRUE / FALSE) of the logic rule.
13-40 Logic Rule Boolean 1
Array [4]
*
False
[0]
[1]
True
[2]
Running
[3]
InRange
[4]
OnReference
[7]
Out of Current Range
[8]
BelowILow
[9]
AboveIHigh
[16]
ThermalWarning
[17]
MainsOutOfRange
[18]
Reversing
50
Shows number of the alarm.
Number of counts.
Number of counts.
Select operator to be used in comparison.
Result of evaluation is True if variable selected in par. 13-10 is smaller than fixed value in par. 13-12. Result is False if
variable selected in par. 13-10 is greater than fixed value in par. 13-12.
Result of evaluation is True if variable selected in par. 13-10 is approximately equal to fixed value in par. 13-12.
Inverse logic of option [0].
Enter "trigger level" for variable monitored by this comparator.
Enter value to define duration of the False output from programmed timer. A timer is only False if it is started by an
action and until the given timer value has elapsed.
Select first boolean input for selected logic rule.
Enters False in logic rule.
Enters True in logic rule.
See par. 5-4* [5] for description.
See par. 5-4* [7] for description.
See par. 5-4* [8] for description.
See par. 5-4* [12] for description.
See par. 5-4* [13] for description.
See par. 5-4* [14] for description.
See par. 5-4* [21] for description.
Mains voltage is outside the specified voltage range.
See par. 5-4* [25] for description.