*1 : From sending the laser pumping on request to completion of laser pumping, the following time will be required.
• LP-GS series: about 8 to 15 seconds
• LP-RC series: about 10 seconds
• LP-RF series: about 7 seconds
• LP-RV series: about 1 second
*2 : Commands from No. 2 to No. 5 above chart can be sent right after turning on laser pumping (without waiting for the
laser pumping completion).
*3 : SIN command can be accepted only when the shutter is opened. There is a delay time of around 200ms to max. 1
second from sending shutter open/close command for the actual shutter open/close operation time.
Besides, with LP-RC series for the first operation of opening shutter after the laser pumping on, it takes around 300ms
to max. 4 seconds.
*4 : For LP-RC/LP-RF/LP-RV series, you can know the timing of SIN command input by confirming DATA WAIT OUT (No.38)
signal of I/O connector is ON.
• To use SIN command, set "Characters specified by SIN command" of the functional character to the file in Laser Marker
NAVI smart beforehand.
• Send SIN command by every marking triggers. READY OUT will not turn on until SIN command is sent.