About Detect Trigger (common)
This function detects an inspect target inside
the inspection area with Position Adjustment
No.0. It repeats image capturing and execution
of Position Adjustment No.0 until the Position
Adjustment detects the target (Judgement =
OK), and then other checkers are executed
and results are output. ("Execute inspection" in
the figure on the right.)
In Continuous Inspection
After an inspection is complete, the device
executes image capture and Position
Adjustment No.0 again.
The next inspection is not executed if the
following judgement of Position Adjustment
No.0 is "OK" (No.4 in the right figure).
After "NG" judgement of Position Adjustment
No.0 is returned by reasons such as the firstly
inspected object moving out of the area (No.5
in the right figure), "OK" judgement of the
checker executes the next inspection in the
same way as the first inspection.
How to set Continuous Inspection: See page
336.
·
When execution mode is "User Defined", the Position Adjustment of the smallest number in the execution
block is executed repeatedly.
For example, Position Adjustment No.200 for block No.2 and Position Adjustment No.900 for block No.9.
·
When Inspection Process mode is "Parallel", Detect Trigger (common) cannot be used.