ADDR
2040
Volts/Hertz Alarm
2041
Assign Alarm Relays (2-5)
2042
Volts/Hertz Alarm Pickup
2043
Volts/Hertz Alarm Delay
2044
Volts/Hertz Alarm Events
2045
Volts/Hertz Trip
2046
Assign Trip Relays (1-4)
2047
Volts/Hertz Trip Pickup
2048
Volts/Hertz Trip Delay
2049
Volts/Hertz Curve Reset Rate
204A
Volts/Hertz Trip Element
VOLTAGE ELEMENTS / PHASE REVERSAL
2060
Phase Reversal Trip
2061
Assign Trip Relays (1-4)
VOLTAGE ELEMENTS / UNDERFREQUENCY
2080
Block Underfrequency From Online
2081
Voltage Level Cutoff
2082
Underfrequency Alarm
2083
Assign Alarm Relays (2-5)
2084
Underfrequency Alarm Level
2085
Underfrequency Alarm Delay
2086
Underfrequency Alarm Events
2087
Underfrequency Trip
2088
Assign Trip Relays (1-4)
2089
Underfrequency Trip Level 1
208A
Underfrequency Trip Delay 1
208B
Underfrequency Trip Level 2
208C
Underfrequency Trip Delay 2
VOLTAGE ELEMENTS / OVERFREQUENCY
20A0
Block Overfrequency From Online
20A1
Voltage Level Cutoff
20A2
Overfrequency Alarm
20A3
Assign Alarm Relays (2-5)
20A4
Overfrequency Alarm Level
20A5
Overfrequency Alarm Delay
20A6
Overfrequency Alarm Events
20A7
Overfrequency Trip
20A8
Assign Trip Relays (1-4)
20A9
Overfrequency Trip Level 1
20AA
Overfrequency Trip Delay 1
20AB
Overfrequency Trip Level 2
20AC
Overfrequency Trip Delay 2
VOLTAGE ELEMENTS / NEUTRAL OVERVOLTAGE (FUNDAMENTAL)
20C0
Neutral Overvoltage Alarm
20C1
Assign Alarm Relays (2-5)
20C2
Neutral Overvoltage Alarm Level
20C3
Neutral Overvoltage Alarm Delay
20C4
Neutral Overvoltage Alarm Events
20C5
Neutral Overvoltage Trip
20C6
Assign Trip Relays (1-4)
20C7
Neutral Overvoltage Trip Level
20C8
Neutral Overvoltage Trip Delay
20C9
Supervise With Digital Input
1, 2, 3
See Table footnotes on page page 42
30
Table CG–1: 489 Memory Map (Sheet 18 of 30)
Name
RANGE
STEP
0 to 2
1
1 to 4
1
50 to 199
1
1 to 1500
1
0 to 1
1
0 to 2
1
0 to 3
1
50 to 199
1
1 to 1500
1
0 to 9999
1
0 to 3
1
0 to 2
1
0 to 3
1
0 to 5
1
50 to 99
1
0 to 2
1
1 to 4
1
2000 to 6000
1
1 to 50000
1
0 to 1
1
0 to 2
1
0 to 3
1
2000 to 6000
1
1 to 50000
1
2000 to 6000
1
1 to 50000
1
0 to 5
1
50 to 99
1
0 to 2
1
1 to 4
1
2501 to 7000
1
1 to 50000
1
0 to 1
1
0 to 2
1
0 to 3
1
2501 to 7000
1
1 to 50000
1
2501 to 7000
1
1 to 50000
1
0 to 2
1
1 to 4
1
20 to 1000
1
1 to 1200
1
0 to 1
1
0 to 2
1
0 to 3
1
20 to 1000
1
1 to 1200
1
0 to 1
1
489 GENERATOR MANAGEMENT RELAY – COMMUNICATIONS GUIDE
UNITS
FORMAT
DEFAULT
F115
F50
× Nominal
F3
s
F2
F105
F115
F50
× Nominal
F3
s
F2
s
F2
F211
F115
F50
s
F1
× Rated
F3
F115
F50
Hz
F3
5950
s
F2
F105
F115
F50
Hz
F3
5950
s
F2
Hz
F3
5800
s
F2
s
F1
× Rated
F3
F115
F50
Hz
F3
6050
s
F2
F105
F115
F50
Hz
F3
6050
s
F2
Hz
F3
6200
s
F2
F115
F50
Vsec
F2
s
F2
F105
F115
F50
Vsec
F2
s
F2
F103
0
16
100
30
0
0
1
100
10
14
0
0
1
1
50
0
16
50
0
0
1
600
300
1
50
0
16
50
0
0
1
600
300
0
16
30
10
0
0
1
50
10
0