GE 489 Communications Manual page 26

Generator management relay
Hide thumbs Also See for 489:
Table of Contents

Advertisement

ADDR
11C5
Generator Phase Sequence
SYSTEM SETUP / SERIAL START/STOP
11E0
Serial Start/Stop Initiation
11E1
Startup Initiation Relays (2-5)
11E2
Shutdown Initiation Relays (1-4)
11E3
Serial Start/Stop Events
DIGITAL INPUTS / BREAKER STATUS
1200
Breaker Status
DIGITAL INPUTS / GENERAL INPUT A
1210
Assign Digital Input
1211
Asserted Digital Input State
1212
Input Name
1218
Block Input From Online
1219
General Input A Control
121A
Pulsed Control Relay Dwell Time
121B
Assign Control Relays (1-5)
121C
General Input A Control Events
121D
General Input A Alarm
121E
Assign Alarm Relays (2-5)
121F
General Input A Alarm Delay
1220
General Input A Alarm Events
1221
General Input A Trip
1222
Assign Trip Relays (1-4)
1223
General Input A Trip Delay
DIGITAL INPUTS / GENERAL INPUT B
1230
Assign Digital Input
1231
Asserted Digital Input State
1232
Input Name
1238
Block Input From Online
1239
General Input B Control
123A
Pulsed Control Relay Dwell Time
123B
Assign Control Relays (1-5)
123C
General Input B Control Events
123D
General Input B Alarm
123E
Assign Alarm Relays (2-5)
123F
General Input B Alarm Delay
1240
General Input B Alarm Events
1241
General Input B Trip
1242
Assign Trip Relays (1-4)
1243
General Input B Trip Delay
DIGITAL INPUTS / GENERAL INPUT C
1250
Assign Digital Input
1251
Asserted Digital Input State
1252
Input Name
1258
Block Input From Online
1259
General Input C Control
125A
Pulsed Control Relay Dwell Time
125B
Assign Control Relays (1-5)
125C
General Input C Control Events
125D
General Input C Alarm
125E
Assign Alarm Relays (2-5)
125F
General Input C Alarm Delay
1260
General Input C Alarm Events
1, 2, 3
See Table footnotes on page page 42
22
Table CG–1: 489 Memory Map (Sheet 10 of 30)
Name
RANGE
STEP
0 to 2
1
0 to 1
1
1 to 4
1
0 to 3
1
0 to 1
1
0 to 1
1
0 to 7
1
0 to 1
1
0 to 12
1
0 to 5000
1
0 to 1
1
0 to 250
1
0 to 4
1
0 to 1
1
0 to 2
1
1 to 4
1
1 to 50000
1
0 to 1
1
0 to 2
1
0 to 3
1
1 to 50000
1
0 to 7
1
0 to 1
1
0 to 12
1
0 to 5000
1
0 to 1
1
0 to 250
1
0 to 4
1
0 to 1
1
0 to 2
1
1 to 4
1
1 to 50000
1
0 to 1
1
0 to 2
1
0 to 3
1
1 to 50000
1
0 to 7
1
0 to 1
1
0 to 12
1
0 to 5000
1
0 to 1
1
0 to 250
1
0 to 4
1
0 to 1
1
0 to 2
1
1 to 4
1
1 to 50000
1
0 to 1
1
489 GENERATOR MANAGEMENT RELAY – COMMUNICATIONS GUIDE
UNITS
FORMAT
DEFAULT
F124
0
F105
0
F50
0
F50
0
F105
0
F209
1
F210
0
F131
0
F22
_
s
F1
0
F105
0
s
F2
0
F50
0
F105
0
F115
0
F50
16
s
F2
50
F105
0
F115
0
F50
1
s
F2
50
F210
0
F131
0
F22
_
s
F1
0
F105
0
s
F2
0
F50
0
F105
0
F115
0
F50
16
s
F2
50
F105
0
F115
0
F50
1
s
F2
50
F210
0
F131
0
F22
_
s
F1
0
F105
0
s
F2
0
F50
0
F105
0
F115
0
F50
16
s
F2
50
F105
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents