MESSAGE ROUTER
(CLASS 02H)
DEVICENET OBJECT
(CLASS 03H)
D485 MODBUS TO DEVICENET CONVERTER – USER GUIDE
The values for the status attribute (attribute 5) are shown below.
Bit(s)
Name
0
Module owned. A master has allocated the module.
1
Reserved
2
Configured
3 to 7
Reserved
8
Minor recoverable fault
9
Minor recoverable fault
10
Major recoverable fault
11
Major unrecoverable fault
12 to 15
Reserved
Services:
Class services: Get Attribute Single
Table 3–5: Class attributes for message router object 02h
Attr.
Access
Name
1
Get
Revision
Services:
Class services: Get Attribute Single
Instance services: Get Attribute Single
Table 3–6: Class attributes for DeviceNet object 03h
Attr.
Access
Name
1
Get
Revision
Table 3–7: Instance attributes for DeviceNet object 03h
Attr.
Access
Name
1
Get
MAC ID
2
Get
Baud rate
3
Get
Allocation
information
Type
Value
Description
UINT
0001h
Revision 1
Type
Value
Description
UINT
0002h
Revision 2
Type
Value
Description
USINT
N/A
Currently used MAC ID
USINT
N/A
Currently used baud rate:
0 = 125 kbps, 1 = 250 kbps, and
2 = 500 kbps
BYTE
N/A
Allocation choice byte
USINT
N/A
Master MAC ID
DATA EXCHANGE