Breaker protection system
Hide thumbs Also See for c60:
Table of Contents

Advertisement

CHAPTER 5: SETTINGS
— This setting specifies the bottom 20-character line of the user-programmable message and is
PUSHBTN 1 ON TEXT
displayed when the pushbutton is in the "on" position. See the User-definable Displays section for instructions on entering
alphanumeric characters from the keypad.
— This setting specifies the bottom 20-character line of the user-programmable message and is
PUSHBTN 1 OFF TEXT
displayed when the pushbutton is activated from the on to the off position and the
This message is not displayed when the
implied to be "Off" upon its release. The length of the "Off" message is configured with the
PROPERTIES  FLASH MESSAGE TIME
— This setting specifies the time required for a pushbutton to be pressed before it is deemed active. This
PUSHBTN 1 HOLD
timer is reset upon release of the pushbutton. Note that any pushbutton operation requires the pushbutton to be pressed a
minimum of 50 ms. This minimum time is required prior to activating the pushbutton hold timer.
— This setting assigns the FlexLogic operand serving to operate the pushbutton element and to assert
PUSHBTN 1 SET
operand. The duration of the incoming set signal must be at least 100 ms.
PUSHBUTTON 1 ON
— This setting assigns the FlexLogic operand serving to reset pushbutton element and to assert
PUSHBTN 1 RESET
operand. This setting is applicable only if pushbutton is in latched mode. The duration of the incoming
PUSHBUTTON 1 OFF
reset signal must be at least 50 ms.
— This setting enables the user-programmable pushbutton autoreset feature. This setting is applicable
PUSHBTN 1 AUTORST
only if the pushbutton is in the "Latched" mode.
— This setting specifies the time delay for automatic reset of the pushbutton when in the
PUSHBTN 1 AUTORST DELAY
latched mode.
— This setting assigns the FlexLogic operand serving to inhibit pushbutton operation from the operand
PUSHBTN 1 REMOTE
assigned to the
PUSHBTN 1 SET
— This setting assigns the FlexLogic operand serving to inhibit pushbutton operation from the front panel
PUSHBTN 1 LOCAL
pushbuttons. This locking functionality is not applicable to pushbutton autoreset.
— This setting applies only to "Self-Reset" mode and specifies the duration of the pushbutton
PUSHBTN 1 DROP-OUT TIME
active status after the pushbutton has been released. When activated remotely, this setting specifies the entire activation
time of the pushbutton status; the length of time the operand remains on has no effect on the pulse duration. This setting
is required to set the duration of the pushbutton operating pulse.
— This setting assigns the FlexLogic operand serving to drive pushbutton LED. If this setting is "Off," then
PUSHBTN 1 LED CTL
LED operation is directly linked to the
— If pushbutton message is set to "High Priority," the message programmed in the
PUSHBTN 1 MESSAGE
settings are displayed undisturbed as long as
PUSHBTN 1 ON TEXT
option is not applicable to the
This message can be temporary removed if any front panel keypad button is pressed. However, 10 seconds of keypad
inactivity restores the message if the
If the
is set to "Normal," the message programmed in the
PUSHBTN 1 MESSAGE
are displayed as long as
PUSHBUTTON 1 ON
setting. After the flash time is expired, the default message or other active target message is displayed. The
TIME
instantaneous reset of the flash message is executed if any relay front panel button is pressed or any new target or
message becomes active.
The
setting is linked to
PUSHBTN 1 OFF TEXT
pushbutton element is in the "Latched" mode. The
setting is "High Priority" or "Normal."
MESSAGE
— If this setting is enabled, each pushbutton state change is logged as an event into the event
PUSHBUTTON 1 EVENTS
recorder.
The figures show the user-programmable pushbutton logic.
C60 BREAKER PROTECTION SYSTEM – INSTRUCTION MANUAL
PUSHBUTTON 1 FUNCTION
setting.
or
settings.
PUSHBTN 1 RESET
operand.
PUSHBUTTON 1 ON
setting.
PUSHBTN 1 OFF TEXT
operand is still active.
PUSHBUTTON 1 ON
operand is asserted, but not longer than time period specified by
operand and displays in conjunction with
PUSHBUTTON 1 OFF
PUSHBTN 1 OFF TEXT
PUSHBUTTON 1 FUNCTION
is "Self-reset" as the pushbutton operand status is
PRODUCT SETUP  DISPLAY
operand is asserted. The high priority
PUSHBUTTON 1 ON
and
PUSHBTN 1 ID
PUSHBTN 1 ON TEXT
message displays as "Normal" if the
PRODUCT SETUP
is "Latched."
and
PUSHBTN 1 ID
settings
FLASH MESSAGE
only if
PUSHBTN 1 ID
PUSHBTN 1
5-101
5