FREQUENCY SETTING SIGNAL(Parameter P09)
Caution
!
When the door control is being repeated and the door amplitude is being
detected, the operation direction of the door may change automatically.
Secure personal safety before operation.
Failure to do so could lead to injury.
There are three options for frequency setting signal: by operation panel (near),
by operation mode controlled by door or by command from communication.
In case of door control, encoder mode and SW mode may be selected.
Data
setting
Control method
value
Operation panel
Door control(normal)
encoder method
Door control(repeat)
encoder method
Door control
(door amplitude detect)
encoder method
Door control (normal)
SW method
Door control (repeat)
SW method
Communication RS485

Operation mode of door control

The operation mode of door control may be independently set as OPEN operation
mode and CLOSE operation mode.
According to the position of the door detected by encoder signal, speed change
SW signal and Arrival signal, the operation is carried out by frequency of Parameter
d14 to d27 and the acceleration/deceleration time of d28 to d39.

Acceleration/deceleration time

Data setting value=[0],[3],[6]:
Operation is set according to P01 and P02(1st acceleration time and 1st deceleration time).
Data setting value=[1],[2],[4],[5]:
Depending on operation mode of door control.
Note) If input CLOSE signal to OPEN operation or input OPEN signal to CLOSE operation,
the operation is carried out by 1st acceleration time and 1st deceleration time of P01 and P02.

Door control encoder method

Door control encoder method is operated after the door width setting value of
Parameter d01 is set correctly.
Frequency setting value
Digital setting(by setting value of Fr mode)
Operation mode of door control
(Parameter d14 to d27)
Operation mode of door control
(Parameter d14 to d27)
Detecting frequency of door width
(Parameter d52)
Operation mode of door control
(Parameter d14 to d27)
Operation mode of door control
(Parameter d14 to d27)