Setting The Frequency And Forward/Reverse Run Function With The Operation Panel; Combination Of "Mop Function", "Rotation Direction Setting Mode" And Forward/Reverse Run Function - Panasonic AAD03011 Instruction Manual

Elevator door controller
Table of Contents

Advertisement

Setting the Frequency and Forward/Reverse Run
Function With the Operation Panel
There are following methods for setting the frequency and carrying
out forward/reverse run function with the operation panel.
Frequency setting: [Digital setting method]
Forward/reverse run operation: [Forward run/reverse run method]
1 Setting the frequency
1 Digital setting method (Parameter P09 set to "0")
Press the MODE button on the panel to enter the frequency setting mode (Fr).
Press the SET button, display the frequency to be set with the (up) button
and (down) button, and then press the SET button to enter the data.
The frequency can be changed by holding down the (up) button or (down)
button during operation. (Hereafter, this function is called the MOP function.)
This MOP function cannot be used when parameter P08 is set to "1".
2 Forward/reverse run function
1 Forward run/reverse run method (Parameter P08 set to "1")
Press the button (forward run) or button (reverse run) on the panel
to select the rotation direction. Operation will start when the RUN button
is pressed, and will stop when the STOP button is pressed.
The inverter will not start running just by pressing the RUN button.
2 Sart/stop, rotating direction mode setting method (Parameter P08 set to "0")
First, press the MODE button twice to enter the rotation direction setting
mode (dr). Press the SET button to display the rotation direction data, change
the rotation direction with the (up) button and (down) button, and then press
the SET button to enter the data. (Forward run is set as the factory setting.)
Operation will start when the RUN button is pressed, and will stop when the
STOP button is pressed.
Note) In the case of the door control, the forward run operation is OPEN
operation and the reverse run operation is CLOSE operation.
3 Combination of "Mop function", "rotation direction setting mode"
and forward/ reverse run function.
Forward/reverse
run function
Forward run/reverse
run method
Start/stop, rotation direction
mode setting method
Note) When the forward run/reverse run function is set to "forward run/reverse
run method (parameter P08=1) ", the MOP function cannot be used.
[Start/stop, rotation direction mode setting method]
MOP function
(Cannot be used)
(Can be used)
Details of rotation direction
setting mode
Only monitor function
Monitor function and direction
setting function
25