2.1 INTRODUCTION
c) ORDER CODES WITH PROCESS BUS MODULES
The order codes for the horizontal mount units with the process bus module are shown below.
Table 2–6: B30 ORDER CODES (HORIZONTAL UNITS WITH PROCESS BUS)
B30
-
*
**
- *
BASE UNIT
B30
|
|
CPU
T
|
U
|
V
|
2
SOFTWARE
00
01
03
04
A0
A1
A3
A4
B0
B1
B3
B4
C0
C1
C3
C4
D0
D1
D3
D4
E0
E1
E3
E4
F0
F1
F3
F4
G0
G1
G3
G4
MOUNT/COATING
FACEPLATE/ DISPLAY
POWER SUPPLY
(redundant supply must
be same type as main supply)
PROCESS BUS MODULE
CONTACT INPUTS/OUTPUTS
INTER-RELAY
COMMUNICATIONS
(select a maximum of 1 per unit)
2-10
*
* - F
**
- H
**
- L
**
- N
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
H
|
|
|
|
|
A
|
|
|
|
|
C
|
|
|
|
D
|
|
|
|
R
|
|
|
|
A
|
|
|
|
P
|
|
|
|
G
|
|
|
|
S
|
|
|
|
B
|
|
|
|
K
|
|
|
|
M
|
|
|
|
Q
|
|
|
|
U
|
|
|
|
L
|
|
|
|
N
|
|
|
|
T
|
|
|
|
V
|
|
|
|
W
|
|
|
|
Y
|
|
|
|
H
|
|
|
H
|
|
|
L
|
|
|
L
|
|
|
|
81
|
XX
XX
XX
4A
4B
4C
4D
4L
67
6A
6B
6C
6D
6E
6F
6G
6H
6K
6L
6M
6N
6P
6R
6S
6T
6U
6V
B30 Bus Differential System
**
- S
**
- W/X
**
Full Size Horizontal Mount
|
|
|
Base Unit
|
|
|
RS485 with 3 100Base-FX Ethernet, multimode, SFP with LC
|
|
|
RS485 with 1 100Base-T Ethernet, SFP RJ-45 + 2 100Base-FX Ethernet, multimode, SFP with LC
|
|
|
RS485 with 3 100Base-T Ethernet, SFP with RJ-45
|
|
|
No software options
|
|
|
Ethernet Global Data (EGD) protocol
|
|
|
IEC 61850 protocol
|
|
|
IEC 61850 and Ethernet Global Data (EGD) protocols
|
|
|
CyberSentry Lvl 1
|
|
|
CyberSentry Lvl 1 and Ethernet Global Data
|
|
|
CyberSentry Lvl 1 and IEC 61850
|
|
|
CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
|
|
|
IEEE 1588
|
|
|
IEEE 1588 and Ethernet Global Data
|
|
|
IEEE 1588 and IEC 61850
|
|
|
IEEE 1588, Ethernet Global Data, and IEC 61850
|
|
|
Parallel Redundancy Protocol (PRP)
|
|
|
PRP and Ethernet Global Data
|
|
|
PRP and IEC 61850
|
|
|
PRP, Ethernet Global Data, and IEC 61850
|
|
|
IEEE 1588 and CyberSentry Lvl 1
|
|
|
IEEE 1588, CyberSentry Lvl 1, and Ethernet Global Data
|
|
|
IEEE 1588, CyberSentry Lvl 1, and IEC 61850
|
|
|
IEEE 1588, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
|
|
|
IEEE 1588 and PRP
|
|
|
IEEE 1588, PRP, and Ethernet Global Dada
|
|
|
IEEE 1588, PRP, and IEC 61850
|
|
|
IEEE 1588, PRP, Ethernet Global Data, and IEC 61850
|
|
|
PRP and CyberSentry Lvl1
|
|
|
PRP, CyberSentry Lvl1, and Ethernet Global Data
|
|
|
PRP, CyberSentry Lvl 1, and IEC 61850
|
|
|
PRP, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
|
|
|
IEEE 1588, PRP, and CyberSentry Lvl 1
|
|
|
IEEE 1588, PRP CyberSentry Lvl 1, Ethernet Global Data
|
|
|
IEEE 1588, PRP CyberSentry Lvl 1, and IEC 61850
|
|
|
IEEE 1588 PRP, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
|
|
|
Horizontal (19" rack)
|
|
|
Horizontal (19" rack) with harsh-environmental coating
|
|
|
English display
|
|
|
French display
|
|
|
Russian display
|
|
|
Chinese display
|
|
|
English display with 4 small and 12 large programmable pushbuttons
|
|
|
French display with 4 small and 12 large programmable pushbuttons
|
|
|
Russian display with 4 small and 12 large programmable pushbuttons
|
|
|
Chinese display with 4 small and 12 large programmable pushbuttons
|
|
|
Enhanced front panel with English display
|
|
|
Enhanced front panel with French display
|
|
|
Enhanced front panel with Russian display
|
|
|
Enhanced front panel with Chinese display
|
|
|
Enhanced front panel with English display and user-programmable pushbuttons
|
|
|
Enhanced front panel with French display and user-programmable pushbuttons
|
|
|
Enhanced front panel with Russian display and user-programmable pushbuttons
|
|
|
Enhanced front panel with Chinese display and user-programmable pushbuttons
|
|
|
Enhanced front panel with Turkish display
|
|
|
Enhanced front panel with Turkish display and user-programmable pushbuttons
|
|
|
125 / 250 V AC/DC power supply
|
|
RH
125 / 250 V AC/DC with redundant 125 / 250 V AC/DC power supply
|
|
|
24 to 48 V (DC only) power supply
|
|
RL
24 to 48 V (DC only) with redundant 24 to 48 V DC power supply
|
|
|
Eight-port digital process bus module
XX
XX
No Module
4A
|
4 Solid-State (no monitoring) MOSFET outputs
4B
|
4 Solid-State (voltage with optional current) MOSFET outputs
4C
|
4 Solid-State (current with optional voltage) MOSFET outputs
4D
|
16 contact inputs with Auto-Burnishing
4L
|
14 Form-A (no monitoring) Latching outputs
67
|
8 Form-A (no monitoring) outputs
6A
|
2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 contact inputs
6B
|
2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 contact inputs
6C
|
8 Form-C outputs
6D
|
16 contact inputs
6E
|
4 Form-C outputs, 8 contact inputs
6F
|
8 Fast Form-C outputs
6G
|
4 Form-A (voltage with optional current) outputs, 8 contact inputs
6H
|
6 Form-A (voltage with optional current) outputs, 4 contact inputs
6K
|
4 Form-C and 4 Fast Form-C outputs
6L
|
2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 contact inputs
6M
|
2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 contact inputs
6N
|
4 Form-A (current with optional voltage) outputs, 8 contact inputs
6P
|
6 Form-A (current with optional voltage) outputs, 4 contact inputs
6R
|
2 Form-A (no monitoring) and 2 Form-C outputs, 8 contact inputs
6S
|
2 Form-A (no monitoring) and 4 Form-C outputs, 4 contact inputs
6T
|
4 Form-A (no monitoring) outputs, 8 contact inputs
6U
|
6 Form-A (no monitoring) outputs, 4 contact inputs
6V
|
2 Form-A outputs, 1 Form-C output, 1 Form-A latching output, 8 contact inputs
2A
C37.94SM, 1300nm single-mode, ELED, 1 channel single-mode
2B
C37.94SM, 1300nm single-mode, ELED, 2 channel single-mode
2E
Bi-phase, single channel
2F
Bi-phase, dual channel
2G
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
2H
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
72
1550 nm, single-mode, LASER, 1 Channel
73
1550 nm, single-mode, LASER, 2 Channel
74
Channel 1 - RS422; Channel 2 - 1550 nm, single-mode, LASER
75
Channel 1 - G.703; Channel 2 - 1550 nm, Single-mode LASER
76
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 1 Channel
77
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 2 Channels
7A
820 nm, multi-mode, LED, 1 Channel
7B
1300 nm, multi-mode, LED, 1 Channel
7C
1300 nm, single-mode, ELED, 1 Channel
7D
1300 nm, single-mode, LASER, 1 Channel
7E
Channel 1 - G.703; Channel 2 - 820 nm, multi-mode
7F
Channel 1 - G.703; Channel 2 - 1300 nm, multi-mode
7G
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode ELED
7H
820 nm, multi-mode, LED, 2 Channels
7I
1300 nm, multi-mode, LED, 2 Channels
7J
1300 nm, single-mode, ELED, 2 Channels
7K
1300 nm, single-mode, LASER, 2 Channels
7L
Channel 1 - RS422; Channel 2 - 820 nm, multi-mode, LED
7M
Channel 1 - RS422; Channel 2 - 1300 nm, multi-mode, LED
7N
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, ELED
7P
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, LASER
7Q
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode LASER
7R
G.703, 1 Channel
7S
G.703, 2 Channels
7T
RS422, 1 Channel
7W
RS422, 2 Channels
2 PRODUCT DESCRIPTION
GE Multilin