Circulation Pump Housing Replacement; Circulation Pump Release With Tool; Figure 5-28: Circulation Pump Components; Figure 5-29: Sliding The Circulation Pump Tool Into The Circulation Pump Intake Opening - Miele G 600 Series Technical Information

(all us models)
Hide thumbs Also See for G 600 Series:
Table of Contents

Advertisement

Technical Information

Figure 5-28: Circulation Pump Components

5.37

Circulation Pump Housing Replacement

1. Remove the circulation pump. See Section 5.36.
2. Remove the four (4) screws from the pump housing (Figure 5-28, Item 1).
3. Install the new pump housing and unpressed ring.
5.38

Circulation Pump Release with Tool

1. Open the door.
2. Remove the bottom spray arm and the filter assembly. See Sections 5.17 and
5.23.
3. Slide the releasing tool's prongs horizontally into the circulation pump intake
opening as far as possible. See Figure 5-29.

Figure 5-29: Sliding the Circulation Pump Tool into the Circulation Pump Intake Opening

4. Ensure that the prongs engage in the circulation pump impeller. See Figure 5-30.
66
G 600/G 800

Advertisement