Manuals and User Guides for ZIEHL-ABEGG Ucontrol PXDM50A. We have
1
ZIEHL-ABEGG Ucontrol PXDM50A manual available for free PDF download: Manual
ZIEHL-ABEGG Ucontrol PXDM50A Manual (105 pages)
Universal controller for variable voltage 3- motors
Brand:
ZIEHL-ABEGG
| Category:
Controller
| Size: 2.76 MB
Table of Contents
Table of Contents
2
General
5
Copyright
5
Basis for Device Construction
5
Directions for Use
5
Transport and Storage
6
Obligations of Owner
6
Safety Measures
6
Symbols and Information
6
Electrical/Electronic Equipment
7
Testing in Accordance with Accident Prevention Directives
7
Accessories, Spare Parts
7
Manufacturer Address, Service Address
7
General Description
8
Scope of Applications
8
Technical Data
8
Versions Ucontrol
9
Installation
10
Wall-Mounting, Installation in a Switching Cabinet
10
Outdoor Installation of Devices in Housing Version (IP54)
11
Temperature Influences During Commissioning
11
Systems with Current-Operated Circuit-Breaker
11
Potential at Control Voltage Connections
12
Radiating Interference / Cable Installation
12
Electrical Installations
12
Power Decrease for Ambient Temperatures over 40° C (Derating)
13
Electrical Connections (Refer also to Enclosure: Connection Diagram)
14
Mains Connection
14
Conditions for the Voltage Supply
14
Motor Connection
14
Motor Noise
14
Motor Protection
15
Signal Connection to Analog Inputs (Analog IN1, Analog IN2
15
Output Voltage 0-10V (Analog OUT)
15
Voltage Supply for External Devices (+24 V, GND)
15
Relay Outputs (K1, K2)
15
Digital Inputs (D1, D2)
15
Connection of External Terminal Type AXG-1A(E)
16
Connection RS-485 Interface for MODBUS
16
Controls and Menu Strukture
17
Multipurpose LC Display
17
Menu Operation and Menu Structure
18
The Menu Groups
19
Menu Group Start, Info, Events
20
Start
20
PIN Input
20
Language
20
Reset
21
Operating Mode
21
Ucontrol
21
Info
22
For Mode Speed Controller 1.01
22
For Mode Controller 2.01
23
Events / Malfunctions
24
Programming
25
Selection of the Mode of Operation
25
Speed Controller Mode 1.01
27
Basic Setting
27
Setting for Operation
28
Diagram Default Signal and Output Voltage
28
Menu Plan Speeed Controller 1.01
29
Factory Setting for Mode 1.01 (Preprogrammed) and User Setting
30
Temperature Control Mode 2.01
31
Basic Setting 2.01
31
Function Analog Input 2 (Analog in 2 ) Second Sensor, External Setpoint, Extern Manual Operation
33
Settings for Operation Modes 2.01
34
Functional Diagrams Temperature Control
35
For Mode 2.03 Temperature Controller with Additional Functions: Signal Output 0-10 V
36
For Mode 2.03 Temperature Controller with Additional Functions: Relay Ouput for Heating or Cooling
37
For Mode 2.03 Temperature Controller with Additional Functions: Temperature Monitoring
38
Menu for Temperature Control and Outdoor Depending
39
Menu Plan Temperature Control with Additional Functions 2.03
39
Menu Plan 2.04 and 2.05 Temperature Controls with T W O Sensors Comparison, Average, Difference
40
Factory Setting and User Setting for Modes 2.01
41
Pressure Control for Condensers Refirgeration 3.01
43
Basic Setting 3.01
43
Function Analog Input 2 (Analog in 2 ) Second Sensor, External Setpoint, Extern Manual Operation
45
Settings for Operation Modes 3.01
46
Functional Diagram Pressure Control
47
Menu for Pressure Control Condenser, Alternative Input for Refrigerant
48
Menu Pressure Control Dual Circuit Condenser, Alternative Input for Refrigerant 3.03
48
Factory Setting and User Setting for Modes 3.01
49
Pressure Control for Ventilation Systems 4.01, Setpoint Depending on Outdoor Temperature 4.02
51
Basic Setting 4.01 and
51
Basic Setting and
51
Function Analog Input 2 (Analog in 2 ) Second Sensor, External Setpoint, Extern Manual Operation
53
Settings for Operation Modes 4.01 and 4.02
54
Additional Menu Item for Mode 4.02) with Outside-Temperature Dependent Target-Setpoint
55
Menu for Pressure Control Airconditioning 4.01
56
Pressure Control 4.02 and Setpoint Depending on Outdoor Temperature
56
Factory Setting and User Setting for Modes 4.01
57
Volume Control (Constant) Air Conditioning
59
Basic Setting 5.01 and
59
Basic Setting and
59
Function Analog Input 2 (Analog in 2 ) Second Sensor, External Setpoint, Extern Manual Operation
61
Settings for Operation Modes 5.01 and 5.02
62
Additional Menu Item for Mode 5.02 with Outside-Temperature Dependent Setpoint
63
Menu for Volume Control Airconditioning 5.01
64
Menu for Volume Control Airconditioning
64
Depending on Outdoor Temperature 5.02
59
And Setpoint Depending on Outdoor Temperature
64
Factory Setting and User Setting for Modes 5.01
65
Air Velocity Control 6.01
67
Basic Setting
67
Function Analog Input 2 (Analog in 2 ) Second Sensor, External Setpoint, Extern Manual Operation
68
Settings for Operation Modes 6.01
69
Menu for Air Velocity Control 6.01
70
Factory Setting and User Setting for Modes 6.01
71
Controller Setup
73
Pin Protection
73
Set Protection
73
Save User Settings in „Save User Setup
74
Alarm Sensors Via Relay on / off (Alarm Sensors)
74
Limit
75
Minimum Speed Cut off (Operation Without Minimum Air Reate)
76
Second Group „Indirectly Controlled" or „100 %-Energized
77
Reverse Action of the Control Function (Actual Value>Set = N+)
78
Controler Configuration (Controller Type) and Controller Action )
79
IO Setup
81
Analog Output a (Analog out 1)
81
Function Analog Output a (Analog out 1)
81
Adjustment Analog Output a
82
Functional Overview of Digital Inputs D1 and D2
83
Enable on / off Function 1D
84
External Fault Function 2D
84
Limit on / off Function 3D
85
Switch over E1 / E2 Function 4D
85
Set Intern 1 / Set Intern 2 Or. Setpoint 1/2 Function 5D
86
Intern / Extern Function 6D
87
Automatic Control / Speed Manual Internal (Menu Speed Maunal) Function 7D
88
Reverse Action of Control Function Actual Value>Set = N+ or Actual Value>Set = N- Function 8D
88
Inverting Analog Inputs E1 and E2
89
Function and Inverting for Relay Outputs K1 and K2
90
Network for Several Divices by MODBUS
91
MODBUS - RTU (Remote Terminal Unit)
91
External Display
91
Reading and Writing Parameters
91
Limits
93
Limit Indication Depending on Modulation
93
Limit Indication Depending on Setting or Sensor Signal
93
Limit Indication Depending on Offset to Setpoint
95
Motorsetup
97
Adjusting of Cosj for the Connected Motor
97
Setting for Rampup Time and Rampdown Time
97
Suppression of Speeds
98
Diagnostics Menu
99
Enclosure
101
Connection Diagram
101
Connection Suggestion for Several Motors with Motor Protection Unit Type STDT
102
Dimension Sheet IP54 Model Range
103
Dimension Sheet IP20 Model Range
104
Pxdm25/35(A)E
104
Advertisement
Advertisement
Related Products
ZIEHL-ABEGG Ucontrol PXDM5
ZIEHL-ABEGG Ucontrol PXDM5A
ZIEHL-ABEGG Ucontrol PXDM50
ZIEHL-ABEGG Ucontrol PXDM50E
ZIEHL-ABEGG Ucontrol PXDM50AE
ZIEHL-ABEGG Ucontrol PXDM10A
ZIEHL-ABEGG Ucontrol PXDM12
ZIEHL-ABEGG Ucontrol PXDM15A
ZIEHL-ABEGG Ucontrol PXDM35
ZIEHL-ABEGG Ucontrol PXDM35A
ZIEHL-ABEGG Categories
Fan
Engine
DC Drives
Control Unit
Controller
More ZIEHL-ABEGG Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL