Sign In
Upload
Manuals
Brands
ZIEHL-ABEGG Manuals
Control Unit
CXE/AVE
ZIEHL-ABEGG CXE/AVE Manuals
Manuals and User Guides for ZIEHL-ABEGG CXE/AVE. We have
1
ZIEHL-ABEGG CXE/AVE manual available for free PDF download: Operating Instructions Manual
ZIEHL-ABEGG CXE/AVE Operating Instructions Manual (121 pages)
UNIcon MODBUS Master, Universal control module
Brand:
ZIEHL-ABEGG
| Category:
Control Unit
| Size: 3 MB
Table of Contents
Table of Contents
2
1 General Notes
5
Validity
5
Structure of the Operating Instructions
5
Target Group
5
Exclusion of Liability
5
Copyright
5
2 Safety Instructions
5
Intended Use
6
Explanations of Symbols
6
Product Safety
6
Requirements Placed on the Personnel / Due Diligence
6
Start-Up and During Operation
7
Work on the Device
7
Modifications / Interventions in the Device
7
Operator's Obligation of Diligence
7
Employment of External Personnel
7
3 Product Overview
8
Application
8
Maintenance
8
Transport
8
Storage
8
Disposal / Recycling
8
4 Mounting
8
General Notes
8
Prerequisites for Mounting
9
Outdoor Installation
10
Installation Location for Agriculture
10
Temperature Influences During Commissioning
10
5 Electrical Installation
10
Safety Precautions
10
EMC-Compatible Installation of Control Lines
11
Mains Connection
11
Signal Input or Sensor Connection (E1, E2)
11
Control Outputs 0 - 10 V (A1, A2)
12
Voltage Supply for External Devices (+ 24 V, GND)
12
Digital Inputs (D1, D2)
12
Relay Outputs (K1, K2)
12
Interfaces for MODBUS RTU
13
Addressing Member MODBUS Master Interface
14
USB-Interface
16
Potential at Control Voltage Connections
16
6 Select Operation Mode
17
Mode and Signal Input
17
Operation with a Second Control Circuit
18
External Setpoint / External Speed Setting in Manual Operation
21
Start-Up
22
Prerequisites for Commissioning
22
Procedure for Commissioning
22
Controls and Menu
23
Multipurpose LC Display and Keyboard
23
Example for Programming Mode 2.01 in "Base Setup
24
Menu Structure
24
Overview Menu Groups
26
Programming
27
Speed Controller
27
Speed Controller with Setting by External Signal
27
Speed Controller with Direct Setting by Keyboard 1.02
29
Temperature Control 2.01
31
Basic Setting 2.01
31
Settings for Operation Modes 2.01
32
Functional Diagrams Temperature Control
34
Additionally for (Controller Output 2 with Function )
35
Additionally for 2.03 (Controller Output 2 with Function | 6A | )
35
For Mode 2.03 : Relay Output for Heating or Cooling
36
Relay Output for Temperature Monitoring
37
Pressure Control for Condensers Refrigeration 3.01
37
Base Setup 3.01
37
Setting for Operation Modes 3.01
39
Functional Diagrams Pressure Control Condensers
41
Pressure Control Airconditioning 4.01
42
Base Setup 4.01
42
Setting for Operation Modes 4.01
43
Volume Control 5.01 and 5.02
45
Basic Setting 5.01 and 5.02
45
Setting for Operation Modes 5.01
47
Air Velocity Control 6.01
48
Base Setup 6.01
48
Settings for Operation Modes 6.01
50
Menu Group Start
51
Menu Group Info
52
Controller Setup
53
PIN Protection Activate, PIN0010
53
Set Protection Activate, PIN 1234
54
Save User Settings Restore with PIN 9090
54
Sensor Alarm on / off
54
Limit
55
Minimum Switch-Off
55
Reverse Action of the Control Function
56
Controller Configuration
56
Group Control
57
Version "1": Two Controlled Groups
58
Variant "2": One Controlled Group and up to Three Switched Groups
59
Display Text for External Message
61
Offset Control Signal
62
Selection Amplifier (Comparator) Control Circuit 1 or 2 at Output A1
62
COM2 Function
63
Data on the Total Control Deviation
63
IO Setup
63
Overview Menu Group IO Setup
63
Allocation: Virtual Ios / Real Ios
64
Analog Outputs "AO
66
Analog Inputs "AI
69
Digital Outputs "DO
72
Digital Inputs "DI
75
Enable ON/OFF Function | 1D
77
External Message, Function | 2D
78
Limit on / OFF, Function | 3D
78
Switch over Input "E1" / "E2", Function | 4D
78
(Operation with One Control Cicuit)
78
Output Control Circuit 2 Additional to "A2" on "A1", Function
79
Set 1/2 or Setpoint 1/2, Function
79
Intern / Extern Function | 6D
80
Automatic Control / Speed Manual Function | 7D | (Mode 2.01 )
80
Reverse Action of Control Function
81
Function | 8D
81
Switch over Setpoint 1/2 for Control Circuit 2 | 9D
81
Setting Max. Speed on / off Function | 11D
82
Freeze Function" = Maintain Momentary Modulation Value, Function
82
Switch over Setpoint 1/2 and Pband 1/ 2 for Control Circuit 1 | 15D
82
Switch over Setpoint 1/2 and Pband 1/2 for Control Circuit 2 | 16D
83
Timer Function Overwrite | 21D
84
Limits
85
Limit Indication Depending on Modulation
85
Limit Indication Depending on Setting or Sensor Signal
86
Limit Indication Depending on (Offset) to Setpoint
88
Time Switch
89
Function of the Timer
89
Setting of Time and Date
90
Automatic Summer Time
91
Enter Switching Times
91
Overwrite Timer Function
93
Adjustment of the Real Time Clock
93
MODBUS Slave
93
MODBUS Master
94
Automatic Addressing
95
Manual Addressing
96
Member MOBUS Master
97
Menu Tables
98
Menues of Operating Modes
98
Possible Allocation of the Ios, Pins
106
11 Diagnostics Menu
111
12 Protocol
112
Display and Query of Events and Malfunctions
112
Messages and Trouble Shooting
113
13 Enclosure
116
Technical Data
116
Connection Diagram
118
Dimensions [MM]
119
Index
120
Manufacturer Reference
121
Service Information
121
Advertisement
Advertisement
Related Products
ZIEHL-ABEGG CXE/AV
ZIEHL-ABEGG UNIcon MODBUS Master CXG-24AV
ZIEHL-ABEGG UNIcon MODBUS Master CXG-24/ AVE
ZIEHL-ABEGG CXG-24AVE
ZIEHL-ABEGG UNIcon CTG-150AV
ZIEHL-ABEGG UNIcon CKG-3RVE
ZIEHL-ABEGG UNIcon CKE-3ARV
ZIEHL-ABEGG UNIcon CTG-150AVC
ZIEHL-ABEGG UNIcon CPG-200AVC
ZIEHL-ABEGG UNIcon CPG-1000AVC
ZIEHL-ABEGG Categories
Fan
Engine
DC Drives
Control Unit
Controller
More ZIEHL-ABEGG Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL