Sign In
Upload
Manuals
Brands
Zeta Alarm Systems Manuals
Repeater
Premier AL
Zeta Alarm Systems Premier AL Repeater Manuals
Manuals and User Guides for Zeta Alarm Systems Premier AL Repeater. We have
1
Zeta Alarm Systems Premier AL Repeater manual available for free PDF download: Installation, Commissioning And Maintenance With User Instructions And Manual
Zeta Alarm Systems Premier AL Installation, Commissioning And Maintenance With User Instructions And Manual (162 pages)
Brand:
Zeta Alarm Systems
| Category:
Repeater
| Size: 2.77 MB
Table of Contents
Installation, Commissioning and Maintenance Manual
3
Table of Contents
3
Introduction
9
Overview of Installation and Commissioning
9
General Description
10
Premier al Panel Description
10
Xp 150W-30-7 P.s.e
10
A1579 Motherboard
10
A1580 Display Board
10
A1584 Pse Control Board
10
Figure 1 - Premier al Panel Main Components
10
A1599 Printer
12
A1637 Display Board
12
A1638 Motherboard
12
C1541 3A P.s.e
12
Figure 2 - Global Network Repeater
12
Premier al Global Network Repeater
12
Feature List
13
Functional Specification
13
Additional Functions Relating to EN54
15
Ancillary Functions Not Required by EN54
15
EN54 Optional Functions with Requirements
15
Installation
15
Electrical Safety
16
Installation Instructions
16
Premier al Panel Installation Instructions
17
Installation and Connection of the A1619 Panel Repeater Interface
18
Figure 3 - Panel Repeater Connection Diagram
19
Installation and Connection of the A1620 Network Interface
19
Figure 4 - Network Connection Diagram
20
Table 1 - A1620 Node Address Switch Settings
20
Commissioning
21
Introduction
21
Commissioning Checklist
21
An Overview of the Commissioning Procedure
22
Pre-Commissioning Wiring Check
22
Alarm Circuits
23
Commissioning Procedure
23
Commissioning Loops
23
Commissioning a Network System
24
Premier al Motherboard Features
25
Figure 5 - Motherboard Layout
26
Figure 6 - Power Supply Layout
27
Premier al Power Supply Features and Connections
27
Figure 7 - A1638 Motherboard Layout
28
Figure 8 -Power Supply Layout
29
Premier al Global Network Repeater Power Supply Features and Connections
29
Compatible Loop Field Devices
30
Approved Field Device Order Codes & Descriptions
30
Adjustable Sensitivity Modes
31
Change Time and Date
31
Delay of Operation of Outputs
31
Enabling and Disabling of Functions
31
Overview of User Functions
31
Overview of Engineers Functions
32
Printer Functions
32
Test Functions
32
The Event Log
32
View Suppressed Events
32
Engineer Definable Access Code
33
Day/Night Sensitivity Mode
33
Delay of Operation of Outputs
33
Enabling Site Specific Data Changes
33
Point Configuration
33
Group Allocation
34
Programmable Loop Output Cause/Effect
34
Table 2 - Default Command Output Bits
34
Zone Allocation
34
Panel Input Output Expansion Boards
36
Premier al Global Repeater Panel
36
Panel Cause/Effect Timers
37
Class -Change Modes
37
Power Supply Load Calculation
37
Battery Standby Capacity Calculation
38
Auxiliary Supply
39
Circuit Connection Details
39
Figure 9 - Auxiliary Fire Contact Connection Details
39
Use of Auxiliary Outputs
39
Figure 10 - Auxiliary Fault Contact Connection Details
40
Figure 11 - Monitored Input Circuit Configuration
40
Use of Auxiliary Inputs
40
Alarm Circuits
41
Figure 12 - Class Change Input Circuit Configuration
41
Figure 13 - Alarm Circuit Configuration
41
Loop Design
41
Loop Isolators
42
Loop Voltage Drop Calculation
42
Carry out the Required Fire Drill
43
Panel Events
43
The Fire Condition
43
User Actions
43
The Alert Condition
44
User Actions
44
The ALERT and BUZZER SILENCED Leds Go Steady
44
The Internal Buzzer Silences
44
The FAULT and BUZZER SILENCED Leds Go Steady
45
The Fault Condition
45
The Internal Buzzer Silences
45
User Actions
45
The Maintenance Condition
46
This Facility Is Not Used on the Fyreye Detectors and Is for Future Use
46
The System Fault Condition
47
User Actions
47
Service Engineer Actions
47
Access Mode
47
Quiescent Condition
47
User Controls and Indications
48
How to Enter Numbers
50
How to Set the Time and Date
50
How to Enable and Disable the Panel Delay
51
How to Enable Day Sensitivity Mode
52
How to Enable Night Sensitivity Mode
52
How to Enable Timed Sensitivity Mode
52
How to Enable off Sensitivity Mode
53
How to Enable and Disable a Single Point (Stand-Alone Panel)
54
How to Enable and Disable a Single Point (Network Panel)
55
How to Enable and Disable a Range of Points (Stand-Alone Panel)
56
How to Enable and Disable a Range of Points (Network Panel)
57
How to View Disabled Points
59
How to Enable All Points (Local Panel Only)
60
How to Enable and Disable a Zone of Devices (Stand-Alone Panel)
61
How to Enable and Disable a Zone of Devices (Network Panel)
62
How to Enable and Disable a Range of Zones (Stand-Alone Panel)
63
How to Enable and Disable a Range of Zones (Network Panel)
65
How to View Disabled Zones
66
How to Enable and Disable the Local Printer
67
How to Enable and Disable All Sounding Devices
68
How to Enable and Disable Expansion Board Inputs (Stand-Alone Panel).67
69
How to Enable and Disable an Expansion Board Input (Network Panel)
70
How to Enable and Disable a Range of Expansion Board Inputs (Stand-Alone Panel)
71
How to Enable and Disable a Range of Expansion Board Inputs (Network Panel)
72
How to View Disabled Expansion Board Inputs
74
How to View Suppressed Alerts, Faults and Indications
75
How to View the Event Log
75
How to View Suppressed Disablements
76
How to View the Status of a Point
77
How to Test Devices Using One Person Test Mode
78
How to Test Sounding Devices Using One Person Test Mode
79
How to Clear the Print Queue
80
How to Print the Event Log
80
How to Print Disablements
81
Engineer Functions
82
How to Edit the Panel Delay
83
How to Enable Changes to Site Specific Data
83
How to Change Device Configuration of a Loop
84
How to View Device Configuration of a Loop
85
How to Print the Device Configuration of a Loop
86
How to Edit the Allocation of Devices to a Zone
87
How to Edit the Sensitivity of a Point
87
How to Print the Allocation of Devices to a Zone
88
How to View the Allocation of Devices to a Zone
89
How to Edit the Allocation of Points to a Group
90
How to View the Allocation of Devices to a Group
92
How to Print the Allocation of Devices to a Group
93
How to Edit Loop Output Cause and Effect
94
How to Print Loop Output Cause and Effect
94
How to Change the Remote Evacuate Mode
95
How to Edit Expansion Input Text
95
How to Edit Point Location Text
95
How to Edit the Panel Company Text Display
95
How to Configure the Number of Panel Repeaters
96
How to Edit the Expansion I/O Board Configuration
96
How to Change the Power Fault Polarity
96
How to Edit the Allocation of Inputs to a Group
97
How to Edit the Expansion I/O Board Cause/Effect
98
How to Edit the Panel's Number and Name
99
How to Print Expansion Output Cause and Effect
99
How to Edit the Panel's Network Display Responses
100
How to Edit the Panel's Network User Control Responses
100
How to Edit the Panel's Network Special Function Responses
101
How to Print the Panel's Network Display Responses
101
How to Change the Class Change Modes
102
To Change the Output Bits, Enter the Engineers Menu and Select
102
Annual Inspection
103
Battery Replacement
103
Quarterly Inspection
103
Routine Maintenance
103
APPENDIX A - Engineers Menu Overview
104
APPENDIX B - Glossary of Terms
104
Figure 14 - Premier al Engineers Menu Overview
104
APPENDIX C - Glossary of Terms
106
APPENDIX D - List of Message Abbreviations
107
APPENDIX E - Premier al Mechanical and Environmental Specification
108
APPENDIX F - Premier al Global Network Repeater Mechanicaland
110
Environmental Specification
110
APPENDIX G - Premier al Input and Output Specification
111
Global Network Repeater
114
1 Introduction
116
The Fire Condition
116
The Alert Condition
117
The Fault Condition
118
The System Fault Condition
119
Quiescent Condition
119
Access Mode
119
3 Routine Maintenance
120
Daily Attention
120
Weekly Attention
120
Quarterly Inspection
120
Annual Inspection
120
Battery Replacement
120
4 Overview of User Functions
120
Change Time and Date
120
Delay of Operation of Outputs
120
Adjustable Sensitivity Modes
121
Enabling and Disabling of Functions
121
The Event Log
121
Test Functions
122
View Suppressed Events
122
Printer Functions
122
5 User Controls and Indications
123
6 User Functions
125
How to Enter Numbers
125
How to Set the Time and Date
125
How to Enable and Disable the Panel Delay
126
How to Enable Day Sensitivity Mode
127
How to Enable Night Sensitivity Mode
127
How to Enable Timed Sensitivity Mode
128
How to Enable off Sensitivity Mode
128
How to Access the Disablement Menu Via the Summary Screen
129
How to Enable and Disable a Single Point (Stand-Alone Panel)
129
How to Enable and Disable a Single Point (Network Panel)
130
How to Enable and Disable a Range of Points (Stand-Alone Panel)
131
How to Enable and Disable a Range of Points (Network Panel)
132
How to View Disabled Points
133
How to Enable All Points (Stand-Alone Panel)
134
How to Enable All Local Points (Network Panel)
135
How to Enable All Points Globally (Network Panel)
135
How to Enable All Points at Selected Panel (Network Panel)
136
How to Enable and Disable a Zone of Devices (Stand-Alone Panel)
137
How to Enable and Disable a Zone of Devices (Network Panel)
137
How to Enable and Disable a Range of Zones (Stand-Alone Panel)
139
How to Enable and Disable a Range of Zones (Network Panel)
139
How to View Disabled Zones
141
How to Enable and Disable the Local Printer
141
How to Enable and Disable All Sounding Devices
142
How to Enable and Disable an Expansion Board Input (Stand-Alone Panel)30
142
How to Enable and Disable an Expansion Board Input (Network Panel)
143
How to Enable and Disable a Range of Expansion Board Inputs (Stand-Alone Panel)
144
How to Enable and Disable a Range of Expansion Board Inputs
145
Panel? 001
145
How to View Disabled Expansion Board Inputs
146
How to Enable and Disable All Non-Sounder Devices
147
How to View the Event Log
148
How to View Suppressed Alerts, Faults and Indications
148
How to View Suppressed Disablements
149
How to View the Status of a Point
150
How to Test Devices Using One Person Test Mode
151
How to Test Sounding Devices Using One Person Test Mode
152
How to Clear the Print Queue
153
How to Print the Event Log
153
How to Print Disablements
154
How to Print Texts and Analogue Values
155
APPENDIX A -Premier al Mechanical and Environmental Specification
157
Glossary of Terms
160
Advertisement
Advertisement
Related Products
Zeta Alarm Systems Premier AL Repeater
Zeta Alarm Systems Prem1er Quatro
Zeta Alarm Systems Premier Power Pack
Zeta Alarm Systems PREM1ER EVACS 1-16
Zeta Alarm Systems Premier EXPro
Zeta Alarm Systems Simplicity Plus 64
Zeta Alarm Systems Simplicity Plus 126
Zeta Alarm Systems Simplicity Plus 252
Zeta Alarm Systems Categories
Fire Alarms
Security System
Control Panel
Power Supply
Carbon Monoxide Alarm
More Zeta Alarm Systems Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL