Sign In
Upload
Manuals
Brands
York Manuals
Heat Pump
XP Series
York XP Series Manuals
Manuals and User Guides for York XP Series. We have
3
York XP Series manuals available for free PDF download: Wiring Diagrams, Technical Manual, Installation Manual
York XP Series Technical Manual (79 pages)
XP SERIES IS HEAT PUMP ZJ IS COOLING ONLY OR ELECTRIC COOLING/GAS HEATING 3-5 ton 60 Hertz, R-410A
Brand:
York
| Category:
Heat Pump
| Size: 2 MB
Table of Contents
Technical Guide
3
Description
3
Table of Contents
4
Gas/Electric
4
Component Location
4
Electric/Electric and Heat Pump
5
Nomenclature
6
Standard Features
7
Electric Heat Operation
7
Gas Heat Operation
7
Features and Benefits
7
Factory Installed Options
8
Control Options
8
Field Installed Accessories
9
Outdoor (Condenser) Fan Assembly
10
Unit Cabinet
10
Indoor (Evaporator) Fan Assembly
10
Guide Specifications
10
Unit Controls
11
Gas Heating Section (Single or 2 Stage)
11
Unit Operating Characteristics
11
Electrical Requirements
11
Other Pre-Engineered Accessories Available
12
Other Factory Installed Options
12
Physical Data
13
XP036-060 Physical Data
15
ZJ/XP036-060 Unit Limitations
16
ZJ036-060 Cooling Capacities
17
Capacity Performance
17
ZJ048 (4.0 Ton)
19
ZJ060 (5.0 Ton)
21
XP036-060 Cooling Capacities
23
XP036 (3.0 Ton)
23
XP048 (4.0 Ton)
25
XP060 (5.0 Ton)
27
XP036-060 Heating Capacities
28
Xp036-060
28
Heating Capacities
29
ZJ036-060 Side Duct Application
30
ZJ036 (3.0 Ton)-Side Duct
30
Airflow Performance
30
ZJ048 (4.0 Ton)-Side Duct
31
ZJ060 (5.0 Ton)-Side Duct
32
ZJ036-060 Bottom Duct Application
33
ZJ036 (3.0 Ton)-Bottom Duct
33
ZJ048 (4.0 Ton)-Bottom Duct
34
ZJ060 (5.0 Ton)-Bottom Duct
35
XP036-060 Side Duct Application
36
XP036 (3.0 Ton)-Side Duct
36
XP048 (4.0 Ton)-Side Duct
37
XP060 (5.0 Ton)-Side Duct
38
XP036-060 Bottom Duct Application
39
XP036 (3.0 Ton)-Bottom Duct
39
XP048 (4.0 Ton)-Bottom Duct
40
XP060 (5.0 Ton)-Bottom Duct
41
Additional Static Resistance
42
Altitude/Temperature Correction Factors
42
Electric Heat Minimum Supply Air
43
Indoor Blower Specifications
43
Power Exhaust Specifications
43
Electric Heat Multipliers
43
ZJ/XP Indoor Sound Power Levels
44
ZJ/XP Outdoor Sound Power Levels
44
Sound Performance
44
Without Powered Convenience Outlet
45
Zj036-060
45
Electrical Data
45
With Powered Convenience Outlet
49
Cooling / Heating (24 Volt Thermostat)
53
Cooling Only (24 Volt Thermostat)
53
Typical Field Power and Control Wiring
53
ZJ/XP036-060 Unit Weights
54
Unit 4 Point Load Weight
54
Unit 6 Point Load Weight
54
Weights and Dimensions
54
ZJ036-060 Unit Dimensions
55
ZJ036-060 Cooling Only/Electric Heat Front View
55
XP036-060 Heat Pump/Electric Heat Front View
55
ZJ036-060 Cooling Only/Gas Heat Front View
55
ZJ/XP036-060 Fixed Outdoor Air Motorized Damper Rain Hood
56
ZJ/XP036-060 Rear View
56
ZJ/XP036-060 Roof Curb Dimensions
57
ZJ/XP036-060 Disconnect
57
ZJ/XP036-060 Minimum Clearances
57
ZJ/XP036-060 Utilities Entry
57
ZJ/XP036-060 Typical Applications
58
Accessory Features
59
Typical Wiring Diagrams
59
AC Unit Notes
60
Typical Stand Alone Single Zone CV Control Diagram
60
Controls
61
Commercial Zoning Package
63
Manufacturer Independent
63
Affordable Intelligence
63
Easy Installation
64
TSS – Single Duct Variable Air Volume Terminal
66
Optional Features
67
Construction
67
Hot Water Coils
67
Primary Air Valve
67
TSL – Single Duct Low Height Variable Air Volume Terminal
68
Single Duct Variable Air Volume Terminal (Model TSS)
70
Single Duct Variable Air Volume Terminal - Rectangular (Model TSL)
71
Additional Damper Specifications
72
Applications
73
Benefits
73
Model SEN Specifications
74
Ordering Information
74
Advertisement
York XP Series Installation Manual (53 pages)
R-410A W/SMART EQUIPMENT 15/20 Ton 60 Hertz
Brand:
York
| Category:
Air Conditioner
| Size: 5 MB
Table of Contents
Table of Contents
1
General
2
Safety Considerations
2
Model Number Nomenclature
4
Installation
5
Installation Safety Information
5
Limitations
5
XP180/240 Unit Limitations
6
XP240 Component Location
6
Location
7
Rigging and Handling
7
XP180/240 Unit Weight
8
XP240 Unit 4 Point Load Weight
8
XP240 Unit 6 Point Load Weight
8
XP180 Unit 4 Point Load Weight
8
XP180 Unit 6 Point Load Weight
8
Center of Gravity
8
Utilities Entry
9
XP180/240 Unit Accessory Weights
9
XP240 Unit Dimensions Front View
9
XP180 Unit Dimensions Front View
10
XP180/240 Unit Dimensions Rear View
11
XP180/240 Unit Clearances
12
XP180/240 Unit Dimensions Rain Hood
12
XP180/240 Roof Curb
12
Ductwork
13
Condensate Drain
13
Fixed Outdoor Air Damper
13
Compressors
14
Filters
14
Power and Control Wiring
14
Control Wire Sizes
15
Field Wiring Disconnect - Heat Pump Unit With/Without Electric Heat
15
Typical Field Wiring 24 Volt Thermostat
16
Electrical Data
17
XP180/240 Physical Data
21
Field Installed Electric Heat Accessories
23
Options/Accessories
23
Economizer Sequences
23
Dry Bulb Changeover
23
Single Enthalpy Changeover
23
Dual Enthalpy Changeover
23
Auto
23
Free Cooling Operation
23
Electric Heat Minimum Supply Air
23
Power Exhaust
24
Setpoints
24
Inputs
24
Outputs
24
Operation
24
Smart Equipment™ Economizer Board Details
25
SE-ECO1001-0 Economizer Controller
25
Field Installed BAS-Ready Economizer Power Exhaust Damper Set Point Adjustment
28
Blower Rotation
29
Belt Adjustment
29
Altitude/Temperature Correction Factors
30
Drive Selection
31
Example Supply Air Blower Performance
31
Air Flow Performance - Side Duct Application
32
Air Flow Performance - Bottom Duct Application
33
Air Balance
34
RPM Selection
34
Indoor Blower Specifications
34
Power Exhaust Specifications
34
Pressure Drop Across a Dry Indoor Coil Vs. Supply Air CFM for All Unit Tonnages
34
Additional Static Resistance
35
Sequence of Operation
36
Cooling Sequence of Operation
36
Cooling Operation Errors
36
Safety Controls
37
Compressor Protection
37
Electric Heating Sequence of Operations
37
Defrost Termination
38
Interval between Defrosts
38
Forced Defrost
38
Electric Heat Operation Errors
38
Limit Control Setting
38
Start-Up (Cooling)
39
Electric Heat Anticipator Setpoint
39
Charging the Unit
40
XP180 (15 Ton) Charging Chart
40
XP240 (20 Ton) Charging Chart
40
Maintenance
41
Normal Maintenance
41
Filters
41
Motors
41
Blower Shaft Bearing
41
Outdoor Coil
41
Smart Equipment™ UCB Details
42
Unit Control Board
42
Cable for FC Buses and SA Buses in Order of Preference
47
Start-Up Sheet
48
York XP Series Wiring Diagrams (95 pages)
R-410A, 3 - 6 Ton, 60 Hertz
Brand:
York
| Category:
Air Conditioner
| Size: 15 MB
Advertisement
Advertisement
Related Products
York XH4 Series
York XP SERIES W/SIMPLICITY
York Predator XP090
York Predator XP102
York Predator XP120
York Predator XP150
York XP 036-060
York XP180
York XP240
York 036-048
York Categories
Air Conditioner
Heat Pump
Chiller
Furnace
Air Handlers
More York Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL