Sign In
Upload
Manuals
Brands
WAGNER Manuals
Smoke Alarm
TITANUS PRO-SENS/net Rev.a UL
WAGNER TITANUS PRO-SENS/net Rev.a UL Manuals
Manuals and User Guides for WAGNER TITANUS PRO-SENS/net Rev.a UL. We have
1
WAGNER TITANUS PRO-SENS/net Rev.a UL manual available for free PDF download: Technical Manual
WAGNER TITANUS PRO-SENS/net Rev.a UL Technical Manual (177 pages)
Fire detection Aspirating smoke detector
Brand:
WAGNER
| Category:
Smoke Alarm
| Size: 14 MB
Table of Contents
Table of Contents
3
About this Document
9
Scope of Application
9
Applicable Documents
9
Target Groups
10
Conventions of Representation
11
Warnings
11
Personal Injury
12
Material and Environmental Damage
12
Tips
12
References
13
Further Text Markings
13
Figures
13
Safety
14
Application Limits
14
Intended Use
14
Foreseeable Misuse
15
Qualification of Personnel
16
Project Planner
16
Carrier
16
Installer
17
Commissioning Engineer
17
Operator
17
Service Technician
17
General Safety Information
18
Personal Injury from Sharp Edges and Burrs
18
Personal Injury from Tipping or Falling Loads
18
Personal Injury from Obstacles on the Floor
18
Personal Injury from Obstacles in the Head Area
19
Personal Damage from Noise
19
Environmental Damage from Improper Disposal
19
Safety Signs on Components
19
What to Do During Emergencies
20
Product Description
21
Product Overview
21
Net Basic Device
21
Titanus Pro·sens
21
Displays and Connections
22
Accessories
23
Device Bracket
23
Cable Entries
24
Pipe Adapter for NPS 3/4" Schedule 40 Pipes
24
Test Pipe
25
Network and Logging Modules
25
Diagnostic Interface
26
Accessories for "Special Application
27
Pipe Adapter for Two Channels
27
Air Filters for Areas with Excessive Dirt
28
Sound Absorber
29
Condensate Separator
30
Pipe System
31
Components for "Open Area" and "Special Application
31
Aspiration-Reducing Film Sheets
31
Aspiration-Reducing Clips
32
Components for "Special Application
34
Ceiling Feed-Through for Concealed Installation
34
Purge System
35
Air Return
38
Functional Principle
39
Principle of Fire Detection
39
Principle of Room Monitoring - Open Area/Special Application
41
Principle of Room Monitoring with Air Conditioning - Special Application
42
Principle of Equipment Monitoring - Special Application
43
Performance Characteristics
44
Sensitivity
44
Alarm Stages
44
Logic·sens
45
Reset Via the Fire Alarm Control Panel
45
Relay Output
46
Air Flow Monitoring
46
Network Readiness
47
Aspiration Apertures
47
Point-Type Detector Project Planning
48
Diagnosis
48
Adjustable Fan Voltage
48
Applications
48
General Applications
48
Applications in "Open Area" Mode
49
Applications in "Special Application" Mode
50
Display and Operating Elements
51
Display Elements
51
Project Planning
53
Determining Requirements
53
Laws, Standards and Guidelines
53
Determining the Installation Location
53
Using the TITANUS Pipexpress® Plus Project Planning Software
55
Project Planning Limits
55
Planning the Device
56
Selecting a Detector Module
56
Configuring Settings
58
Pipe Planning for "Open Area
59
Pipe Planning for "Special Application
60
Calculating the Power Supply
60
Calculating the Alarm Current
60
Calculating the Energy Supply Current for Alarm-Ready State
61
Calculating the Quiescent Current
61
Calculating the Minimum Capacity of the Backup Batteries
62
Determining the Rated Battery Capacity
63
Calculating the Charging Current
63
Comparing the Alarm Current and Power Supply Current
64
Calculating the Line Length and Wire Cross-Section
64
Transport
66
Storage
67
Installation
68
Opening the Device
68
Configuring Settings on the Detector Module
69
Default Settings
70
Configuring the Response Sensitivity
71
Configuring the Alarm Delay Time
71
Configuring the Trigger Threshold for Air Flow Monitoring
72
Configuring a Delay Time for the Air Flow Fault
73
Configuring the Fault Display
73
Switching LOGIC·SENS ® on or off
74
Setting the Fan Voltage
74
Setting the Fan Voltage on TITANUS PRO·SENS Net
74
Setting the Fan Voltage on TITANUS PRO·SENS /Net-SL
75
Mounting the Device
77
Installing the Reset Circuit Board
79
Terminating Resistor
80
Establishing the Electrical Connection for the Device
82
Preparing the Electrical Connections
83
Connecting the Device
84
Connecting Terminal Blocks
86
Connection to FACP, with One Alarm Stage (Fire Alarm)
88
Connection to FACP, with Two Alarm Stages (Action Alarm, Fire Alarm)
89
Connection to FACP, with Three Alarm Stages (Alert Alarm, Action Alarm, Fire Alarm)
90
Connection to FACP, with Reset Board and One Alarm Stage (Fire Alarm)
91
Connection to FACP, with Reset Board and Two Alarm Stages (Action Alarm, Fire Alarm)
92
Connection to FACP, with Reset Board and Three Alarm Stages (Alert Alarm, Action Alarm, Fire Alarm)
93
Installing and Connecting the Network Module
94
Installing the Network Module
94
Connecting the Network Module
95
Inserting and Connecting Detector Module II
96
Connecting the Fan
100
Connecting the Fan on TITANUS PRO·SENS /Net
100
Connecting the Fan on TITANUS PRO·SENS /Net-SL
101
Connecting the Diagnostic Interface
103
Installing the Pipe System
104
Installation Instructions
104
Calculating Changes in Length in the Pipe System
107
Selecting Pipe Clips
108
Installing the Aspiration Pipe
109
Creating Aspiration Apertures
110
Installing Components and Accessories - Special Application
112
Installing the Ceiling Feed-Through for Suspended Ceilings
112
Installing the 3-Way Ball Valve (Metal)
114
Installing the Test Adapter
116
Installing Air Filter Type LF-AD-X
117
Installing a Silencer
119
Installing Condensate Separator Type KA-1
121
Installing a Pipe System in Forced Air Flow - Special Application
122
Installing a Pipe System at Inlet and Outlet Openings
122
Installing the Pipe System in the Bypass
124
Applying the Sticker - Special Application
125
Commissioning
126
Calibrating the Air Flow Sensor
126
Types of Calibration
127
Air Pressure-Independent Calibration
127
Air Pressure-Dependent Calibration
129
Testing the Function
130
Testing Device Function with the Test Pipe
130
Installing the Test Pipe
131
Testing the Device
132
Testing Function with Diagnostic Software
133
Connecting and Testing the Pipe System
134
Performing Maintenance Work
134
Documenting Settings
135
Inspection and Maintenance
136
Inspection and Maintenance Intervals
136
Perform Visual Inspection
136
Testing the Pipe System
137
Testing the Detector Module and the Alarm Transmission
137
Checking the Air Flow Value
138
Identifying the Cause for a Deviating Air Flow Value
139
Checking the Air Flow Monitoring and Fault Signal Transmission
140
Troubleshooting
142
Flash Code Table
142
Flash 1X (Error: Internal Voltage Monitoring 1)
143
Flash 2X (Error: Internal Voltage Monitoring 2)
145
Flashing 3X (Error: Fan Voltage Monitoring)
146
Flashing 4X (Error: Air Pressure Correction Voltage Monitoring)
148
Flashing 5X (Fault: Programming Error)
149
LED Flashes 6X or 7X (Error: Internal Errors 1 and 2)
150
8X Flashes (no Fault, Device Initialization)
151
Recognizing Faulty Reporting of Air Flow Fault
152
Repair
154
Replacing the Detector Module
154
Replacing Filter Inserts on Air Filter Type LF-AD-X
156
Purging the Pipe System
157
Decommissioning
159
Dismounting
160
Disposal
161
Technical Data
162
Ambient Data
163
TITANUS PRO·SENS /Net
165
TITANUS PRO·SENS /Net-SL
165
General Device Data
165
Electrical Data
166
Pipe System for Applications in "Open Area" Mode (Normal Mode)
170
Pipe System for "Special Application
170
Appendix
171
Glossary
175
Advertisement
Advertisement
Related Products
WAGNER TITANUS PRO-SENS
WAGNER TITANUS PRO-SENS SL
WAGNER TITANUS PRO-SENSE
WAGNER TITANUS
WAGNER Titanus Micro-Sens
WAGNER TITANIUS TOP-SENS
WAGNER TITANUS SUPER-SENS
WAGNER TITANUS TOP-SENS
WAGNER TITAN ProSpray 3.20
Wagner Tiger 72-300
WAGNER Categories
Paint Sprayer
Lantern
Power Tool
Water Pump
Measuring Instruments
More WAGNER Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL