Sign In
Upload
Manuals
Brands
Vingtor Manuals
Cell Phone
AlphaCom XE20
Vingtor AlphaCom XE20 Manuals
Manuals and User Guides for Vingtor AlphaCom XE20. We have
1
Vingtor AlphaCom XE20 manual available for free PDF download: Installation/Configuration Manual
Vingtor AlphaCom XE20 Installation/Configuration Manual (76 pages)
ACM series
Brand:
Vingtor
| Category:
Cell Phone
| Size: 10 MB
Table of Contents
Table of Contents
2
1 Introduction
5
About this Document
5
Publication Log
5
Related Documentation
5
DNV Type Approval Regulations
5
ACM Test Reports
5
2 ACM System Overview
6
General
6
Figure Configuration E am Le
6
System Architecture of ACM Family
7
ACM Main System Rack
7
Field Equipment
8
Figure 2 the Alphacom XE Server/Exchange Family
8
Supplementary Systems
9
3 System Functions
10
Marine Emergency and Safety Applications
10
Overview
10
Table 1 DNV Requirements
10
Two-Way Voice Communication
11
Public Address and General Alarm
12
Figure 3 Basic PA & GA for Conventional Vessels
14
Figure 4 Basic PA & GA for Passenger Vessels
14
Handsfree Two-Way Communication (Talk-Back)
15
Figure 5 DECT and UHF Interface
15
4 Hardware Installation Instructions
16
General Environment Requirements
16
System Rack Mounting
16
Acm-M-A-V2 / Acm-M-D-V2
16
Acm-48-V10
16
Acm-M-D/Ip72 / Acm-M-D/Ip96
16
Figure 6 Clearance Dimensions for ACM-M-A & ACM-M-D Cabinets
16
Figure 7 Clearance Dimensions for ACM-48-V10 Cabinet
16
Figure 8 Clearance Dimensions for ACM-M-D/IP72 & ACM-M-D/IP96 Cabinets
16
Acm-144-V10 / Aacm-144-V10
17
Installing Feature Boards
17
Hot-Plug
17
AMC-IP - Alphacom Module Controller Board
17
Figure 9 Clearance Dimensions for ACM-144-V10 Cabinet
17
Figure 10 Hot-Plug
17
Board Positions
18
Connection Terminals
18
ACM-M-A-V2 and ACM-M-D
18
Figure Oar Ositions in al Acom
18
Table 2 Board Positions
18
Figure 12 Terminals in ACM-M-A-V2
19
Figure 13 Terminals in ACM-M-D
19
Acm-48-V10
20
ACM-144-V10 and AACM-144-V10
20
Figure 14 Terminals in ACM-48-V10
20
Figure 15 Terminals in ACM-144-V10 & AACM-144-V10
20
Acm-M-D/Ip72 / Acm-M-D/Ip96
21
Power Supply
21
Acm-M-A-V2 / Acm-M-D
21
Acm-48-V10 / Acm-144-V10 / Aacm-144-V10
21
Figure 16 ACM-M-A/D Power Connection
21
Acm-M-D/Ip72 / Acm-M-D/Ip96
22
Cable Dimensions
22
Figure 17 ACM-M-D/IP72 / ACM-M-D/IP96 Power Connection
22
Line Connection Module (LCM)
23
Table 3 Power and Cable Values
23
Figure 18 24 VDC Connections
24
Figure 19 Telephone and Intercom Line Connection Example
24
RCO - Remote Control Outputs
24
Subscriber Lines
24
VDC Power
24
Figure 20 RCO 1-6 Connection & Interface to Alphacom XE7
25
Figure 21 RCI Closing Contact Connection
25
PA Connection
25
RCI - Remote Control Inputs
25
A am Lifier It Ime It out Monitor
26
Table 4 Switch Settings for PA Monitoring
26
Radio / Walkie-Talkie Interface
27
Audio Input - 6 Channels
28
ACM-IP Patch Panel & I/Os
28
Figure 22 Audio Input Connection
28
Table 5 Switch Settings for Radio Monitoring
28
5 Programming & Cable Reference List
29
Station and User Information
29
Station Information
29
Table 6 Station and User Information Example
29
Programming
30
Terminal Connections
30
Additions
31
Integrated PA Interface
31
Table 7 Integrated PA Interface Example
31
I Configuration
32
Trunk Lines
32
Table 9 Trunk Lines Example
32
6 Programming Overview
33
Alphaweb - Getting Started
33
Connecting to ACM Using Alphaweb
34
Saving and Applying Changes
34
Figure 23 Connect PC to Eth0
34
Alphapro - Getting Started
35
PC Setup
35
Insert the HW Dongle
35
Alphapro Menu Structure
35
Creating a New Network and Exchange
35
Data Communication
36
7 Programming Guide
37
Programming Overview
37
Perform Cold Start
37
Cold Start Procedure
37
Cold Start AMC Application Only (Retain IP Settings)
37
Configure I a Ress
37
Figure 24 Cold Start
37
Figure 25 Cold Start to Load Default Database
37
Figure 26 Cold Start and Keep IP Settings
37
Enter License Key
39
Configure Ser Settings
39
General User Settings
39
Table 10 Call Setup Priority
41
Program Different Class of Service for Users
42
Handsfree Two-Way Conversation (Talk-Back)
43
Overview
43
Configuring U Li a Ress an Eneral Alarm
44
Overview
44
Figure 27 Integrated PA & GA Overview
44
Configure Au Io Inter a E Rom S A- to ACM
45
Configure ACM a Ones
47
Configure Au Io Inter a E ACM to S a
48
Feedback - Intercom as PA Panel
50
Delayed PA Message - Recall
50
8 Acm System Racks Specifications
51
Acm-M-A-V2
51
Acm-M-D
51
Acm-48-V10
52
Acm-144-V10
52
Aacm-144-V10
53
Acm-M-D/Ip72 & Acm-M-D/Ip96
53
Environmental Requirements
54
9 Appendix A - Example Configuration Diagrams
55
Two-Way Communication
55
Figure am Le Onfiguration - O- Ay Ommuni Ation
55
Public Address on Conventional Vessels
56
Figure am Le Onfiguration - U Li a Ress on on Entional Essels
56
Integrated Public Address and General Alarm
57
Figure am Le Onfiguration O Integrate a & a - Oo a
57
Figure am Le Onfiguration O Integrate a & a - Oo
58
Drawing Symbols
59
Appendix B - ACM System Components
60
ACM Main System Racks
60
ACM Field Equipment
61
11 Appendix C - Internal Power Wiring in System Racks
63
Acm-M-A-V2
63
Acm-M-D-V2
63
Acm-48-V10
64
Acm-144-V10
64
Acm-M-D/Ip72
65
Acm-M-D/Ip96
65
12 Appendix D - Acm Call Types
66
Appendix E - Audio Messaging
67
Stored Voice Messages
67
Message I Entifi Ation
68
ASVP Software Module
68
ASVP Board
68
Customi E Message Loa
69
Upload Messages from Alphaweb
69
Record Message from a Station
70
Licensing
71
Su Orte Au Io File Ormats
72
Recall
72
Directory Numbers
72
User Interface
73
Optional Settings
73
Simultaneous Recall Operations
74
Hardware and Software Requirements
74
Auto-Attendant
74
Configuration
74
Hardware and License Requirements
75
Advertisement
Advertisement
Related Products
Vingtor AlphaCom XE7
Vingtor AlphaCom XE26
Vingtor AACM-144-V10
Vingtor ACM-144-V10
Vingtor ACM-48-V10
Vingtor ACM-M-A-V2
Vingtor ACM-M-D-V2 AlphaCom XE7
Vingtor ACM-M-D/IP72
Vingtor ACM-M-D/IP96
Vingtor ETB-10
Vingtor Categories
Telephone System
Telephone
Cell Phone
Intercom System
Marine Equipment
More Vingtor Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL