Manuals and User Guides for Viatran DL-ACB2N. We have
1
Viatran DL-ACB2N manual available for free PDF download: Instruction Manual
Viatran DL-ACB2N Instruction Manual (92 pages)
Analog Input Process Meter DL Series
Brand:
Viatran
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Limited Warranty
2
Table of Contents
3
About Viatran
6
Introduction
6
Ordering Information
7
Specifications
8
General
8
Process Input
10
Relays
11
Isolated 4-20 Ma Transmitter Output
12
Modbus ® RTU Serial Communications
12
Compliance Information
13
Safety
13
Electromagnetic Compatibility
13
Safety Information
14
Installation
14
Unpacking
14
Panel Mounting Instructions
15
Figure 2. Panel Mounting Details
15
Figure 1. 1/8 DIN Panel Cutout Dimensions
15
Mounting Dimensions
16
Figure 3. Meter Dimensions - Side View
16
Figure 4. Meter Dimensions - Top View
16
Configuration for 12 or 24 VDC Power Option
17
Figure 5. Jumper Configuration for 12/24 VDC Power
17
Transmitter Supply Voltage Selection (P+, P-)
18
Connections
18
Figure 6. Transmitter Supply Voltage Selection
18
Connectors Labeling
19
Power Connections
19
Figure 7. Connector Labeling for Fully Loaded Meter
19
Figure 8. Power Connections
19
Viatran DL Series Analog Input Process Meter Instruction Manual
20
Figure 9. Transmitters Powered by Internal Supply
20
Figure 12. Relay Connections
21
Figure 11. Voltage Input Connections
21
Figure 13. AC and DC Loads Protection
22
Figure 14. Low Voltage DC Loads Protection
22
4-20 Ma Output Connections
23
Analog Output Transmitter Power Supply
23
F4 Digital Input Connections
23
Figure 15. F4 Digital Input Connections
23
Figure 16. 4-20 Ma Output Connections
23
External Relays & Digital I/O Connections
24
Figure 17. Expansion Modules & DIN Rail Mounting Kit
24
Figure 18. External Relays Module Connections
24
Interlock Relay Feature
25
Switching Inductive Loads
22
Figure 10. Transmitter Powered by Ext. Supply or Self-Powered
20
Signal Connections
20
Modbus RTU Serial Communications
21
Relay Connections
21
Figure 19. Digital I/O Module Connections
25
Figure 20. Interlock Connections
25
Setup and Programming
26
Front Panel Buttons and Status LED Indicators
27
Display Functions & Messages
28
Main Menu
31
Setting Numeric Values
32
Setting up the Meter (Setup)
33
Viatran DL Series Analog Input Process Meter Instruction Manual
35
Setting the Input Units or Custom Tags (Units)
35
Setting the Decimal Point (Dec Pt)
36
Programming the Meter (Prog)
37
Program Menu for Single Scale Process
37
Program Menu for Dual-Scale Level Applications
37
Multi-Point Calibration & Scaling
38
Meterview ® Pro Software
38
Scaling the Meter (SCALE)
38
Dual-Scale for Level Application
39
Calibrating the Meter with External Source (Cal)
41
Setting the Display Parameter & Intensity (Dsplay)
42
Display Setup Menu
43
Setting the Relay Operation (Relay)
44
Setting the Relay Action
45
Programming Set and Reset Points
46
Setting Fail-Safe Operation
46
Programming Time Delay
46
Relay Action for Loss of 4-20 Ma Input (Loop Break)
46
Relay and Alarm Operation Diagrams
47
High Alarm Operation (Set > Reset)
47
Low Alarm Operation (Set < Reset)
48
High Alarm with Fail-Safe Operation (Set > Reset)
49
Low Alarm with Fail-Safe Operation (Set < Reset)
50
Pump Alternation Control Operation
51
Relay Sampling Operation
52
Signal Loss or Loop Break Relay Operation
53
Time Delay Operation
54
Relay Operation Details
55
Fail-Safe Operation
55
Overview
55
Relays Auto Initialization
55
Front Panel Leds
56
Latching and Non-Latching Relay Operation
56
Latching Relay (Latch)
57
Non-Latching Relay (A-Man)
57
Non-Latching Relay (Auto)
57
Acknowledging Relays
58
Figure 21. Acknowledge Relays W/Function Key or Digital Input
58
Latching Relay (Lt-Clr)
58
Pump Alternation Control Applications (Altern)
59
Setting up the Interlock Relay (Force On) Feature
62
Scaling the 4-20 Ma Analog Output (Aout)
63
Reset Menu (Reset)
64
Viatran DL Series Analog Input Process Meter Instruction Manual
64
Viatran DL Series Analog Input Process Meter Instruction Manual Reset Menu (Reset)
64
Control Menu (Contrl)
64
Setting up the Password (Pass)
65
Protecting or Locking the Meter
65
Making Changes to a Password Protected Meter
66
Disabling Password Protection
66
Advanced Features Menu
67
Advanced Features Menu & Display Messages
68
Noise Filter (Filter)
71
Noise Filter Bypass (Bypass)
71
Rounding Feature (Round)
71
Modbus RTU Serial Communications (Serial)
72
Select Menu (Select)
73
Signal Input Conditioning (Functn)
73
Low-Flow Cutoff (Cutoff)
76
Analog Output Programming (Aoutpr)
76
Programmable Function Keys User Menu (User)
77
Tare (Tare)
78
Internal Source Calibration (ICAL)
78
Meter Operation
81
Front Panel Buttons Operation
81
Function Keys Operation
81
F4 Operation
82
Maximum/Minimum Readings
82
Troubleshooting
83
Diagnostics Menu (Diag)
83
Determining Software Version
83
Reset Meter to Factory Defaults
84
Factory Defaults & User Settings
85
Troubleshooting Tips
88
Figure 22. 1/8 DIN Panel Cutout Template
89
Advertisement
Advertisement
Related Products
Viatran DL-ACB0N
Viatran DL-ACB0R
Viatran DL-ACB2R
Viatran DL-ACB4N
Viatran DL-ACB4R
Viatran DL-ACS0N
Viatran DL-ACS0R
Viatran DL-ACS2R
Viatran DL-ACS4N
Viatran DL-ACS4R
Viatran Categories
Transmitter
Transducer
Measuring Instruments
More Viatran Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL