Sign In
Upload
Manuals
Brands
Vertiv Manuals
Air Conditioner
Liebert CRV4 Series
Vertiv Liebert CRV4 Series Manuals
Manuals and User Guides for Vertiv Liebert CRV4 Series. We have
2
Vertiv Liebert CRV4 Series manuals available for free PDF download: User Manual
Vertiv Liebert CRV4 Series User Manual (126 pages)
Brand:
Vertiv
| Category:
Air Conditioner
| Size: 12 MB
Table of Contents
Table of Contents
6
Chapter 1: Introduction
12
Product Introduction
12
Model Nomenclature
12
Product Appearance
14
Main Components
14
EC Compressor
14
Evaporator
14
Electronic Expansion Valve (EEV)
15
Electrode Humidifier
15
EC Fan
15
Electrical Heater
15
Sight Glass
15
Filter Dryer
15
Display Screen
15
Remote Monitoring Software
15
Options
16
Air Pressure Difference Switch
16
Water Leakage Detection Kit
16
Remote Temperature Sensor Kit
16
Monitoring Card
16
Dual Power Module
16
Chapter 2: Installation
17
Equipment Room Consideration
17
Installation Space Requirements
18
Maintenance Space Requirements for Liebert CRV4
18
Environmental Requirements
19
Operating Environment
19
Storage Environment
19
Refrigerant Charging Requirement
20
Transportation, Unpacking and Inspection
20
Transportation and Movement
20
Unpacking
21
Inspection
22
Chapter 3: Mechanical Installation
23
System Arrangement During Installation
23
General Arrangement
23
System Installation Mode
25
Mechanical Parameters
27
Base Plate Piping Location and Dimensions
28
Top Plate Piping Locations & Dimensions
29
Location of Front Air Outlets
30
Installation of the Indoor Unit
31
Leveling the Cabinet
31
Removing the Leveling Feet and Fastening
32
Assembly of the Cabinet Parts
33
Unit Piping Installation
34
Removing Filter Net
35
Connecting the Condensate Water Drainage Piping of the Indoor Unit
35
Electrode Humidifier Water Inlet Piping Connection
37
Connection of the Copper Piping between the Indoor and Outdoor Units
38
Installing Long Piping Kit (for Site Installation)
41
Check Valve Installation
42
Installing the Solenoid Valve
42
Charging Refrigerant and Adding Lubricant Oil
44
Charging Refrigerant
44
Adding Lubricant Oil
45
Removing Transportation Fastener and Vibration Absorber
46
Sealing the Holes of the Top Plate of the Cabinet
48
Checklist for Completed Mechanical Installation
49
Chapter 4: Electrical Installation
50
Task Introduction and Notes
50
Cables to Connect On-Site
50
Installation Notes
50
Liebert CRV4 Cable Connection of Indoor Unit
51
Electrical Port Location of the Indoor Unit
51
Connecting the Power Cable of the Indoor Unit
52
Connecting the Control Cables
53
Water-Under-Floor Sensor
54
SIC Card
54
Rack Temperature Sensor
54
Remote Shutdown
56
Control Signals of the Outdoor Unit
56
External General Alarm
56
Connecting the Solenoid Valve of the Long Piping Kit- (Optional for Site Installation)
56
Teamwork Control
56
Electrical Installation Checklist
57
Chapter 5: Start-Up Commissioning
58
Location of Mcbs
58
Power-On Commissioning
59
Preparation before Commissioning
59
Commissioning Procedures
59
Inspection after Commissioning
61
Chapter 6: Micro-Controller (Color Screen)
62
Features
62
Appearance
62
Control Screen
63
Main Screen
63
Main Interface Control Mode
66
Password Interface
67
Menu Structure
68
Main Menu
68
Run Information
69
Alarm Information
72
Temperature and Humidity
73
Parameter Setting
75
Graph
79
About
79
Chapter 7: Micro-Controller (Text-Screen)
80
Features
80
Appearance
80
Graphic Color Screen
81
Control Buttons
82
Function Description
82
Operational Examples
83
Control Screen
84
Startup Screen
84
Main Screen
84
Password Interface
85
Menu Structure
86
Main Menu
86
Run Information
87
Alarm Information
89
Temperature & Humidity Settings
91
Parameter Settings
91
Alarm Set
92
Humidifier Set
93
Teamwork Set
93
ESP Set
93
Display Set
94
Password Set
94
Help
95
Chapter 8: System Operation and Maintenance
96
Routine Maintenance & Inspection Items (Monthly)
96
Routine Maintenance and Inspection (Semi-Annually)
97
Self-Diagnosing Functions
98
Maintenance of Electrical Control Utilities
98
Maintenance of Electrical Parts
98
Maintenance of Control System
99
Water-Leak-Detector
99
Air Filter Maintenance
101
Fan Kit Maintenance
101
General Maintenance for the Electrode Humidifier
103
Operating Guidelines for the Electrode Humidifier
103
Replacing Humidifier
104
Electrical Heater Maintenance
106
Refrigerating System Maintenance
107
Suction Pressure
107
Discharge Pressure
107
Electronic Expansion Valve (EEV)
107
Air-Cooled Condenser
108
Compressor
108
Drainage System Maintenance
110
Chapter 9: Troubleshooting
112
Troubleshooting of the Fan
112
Troubleshooting of the Heating System
113
Troubleshooting of Compressor and Cooling System
113
Appendix I: Circuit Diagram of Model CR025, CR035 and CR045
116
Appendix II: Display Menu Structure of the Screens
119
Appendix III: Alarm Menu Control Table
121
Appendix IV: Routine Maintenance Inspection Items
122
(Monthly)
122
Appendix V: Routine Maintenance Inspection Items
122
(Semi-Annually)
123
Appendix VI: Table Names and Content of Harmful
125
Substances in Products
125
Advertisement
Vertiv Liebert CRV4 Series User Manual (116 pages)
Air-cooled Precision Air Conditioners
Brand:
Vertiv
| Category:
Air Conditioner
| Size: 18 MB
Table of Contents
Table of Contents
3
Product Overview
7
Product Introduction
7
Model Nomenclature
7
Product Appearance
9
Main Components
9
Pre-Installation Guidance
11
Equipment Room Requirements
11
Installation Space Requirements
11
Environmental Requirements
12
Operating Environment
12
Storage Environment
12
Refrigerant Requirement
13
Handling, Unpacking, and Inspecting the Unit
13
Transporting and Handling the Unit
13
Unpacking the Unit
14
Inspecting the Unit
15
Mechanical Installation
17
Installation Precautions
17
System Installation Layout
18
System General Layout
18
System Installation Diagram
19
Mechanical Parameters
21
Installing the Indoor Unit
26
Leveling the Unit
26
Removing the Leveling Feet and Fixing the Unit
27
Baying the Unit
28
Installing Pipelines
28
Removing the Filter
29
Connecting Condensate Drainage Pipe on Indoor Unit
29
Connecting Electrode Humidifier Water Inlet Pipe
32
Connecting Wet Film Humidifier Water Inlet Pipe
33
Connecting Gas and Liquid Pipes between Indoor and Outdoor Units
35
Adding Extension Kits (On-Site Installation)
39
Charging Refrigerant and Adding Lubricating Oil
42
Removing Transportation Fastener and Vibration Absorber
43
Inspection after Mechanical Installation
44
Electrical Installation
45
Precautions and Procedures
45
Cables to Connect at Installation Site
45
Installation Precautions
45
Wiring for Indoor Unit
46
Indoor Unit Wiring Position
46
Connecting Power Supply Cable for Indoor Unit
47
Connecting the Control Cables
49
Connecting Extension Kit Solenoid Valve (Optional for On-Site Installation)
51
Inspection after Electrical Installation
51
Commissioning the Unit
53
Position of Circuit Breaker
53
Commissioning before Start-Up
54
Preparation for Commissioning
54
Commissioning Procedures
54
Inspection after Commissioning
55
Display Screen Operation
57
Features
57
Appearance
57
Interface
58
Main Interface
58
Control Mode
60
Password Interface
61
Menu Structure
62
Main Menu
62
Operating Status
63
Alarm Information
66
Temperature and Humidity Setting
69
Parameter Setting
70
Temperature and Humidity Curve
77
Version Information
78
Maintenance
79
Routine Maintenance Inspection (Monthly)
79
Routine Maintenance Inspection (Semi-Annually)
80
Self-Diagnostic Test
81
Electrical Connection Check
81
Electrical System Maintenance
81
Control System Maintenance
82
Water Leak Detection Sensor
83
Filter Maintenance
83
Fan Component Maintenance
83
Electrode Humidifier Maintenance
84
Instructions for Operating Electrode Humidifier
85
Replacing the Humidifier
86
Wet Film Humidifier Maintenance
88
Instructions for Operating Wet Film Humidifier
88
Replacing the Wet Film Humidifier
88
Maintaining Water Inlet Solenoid Valve Filter
89
Electric Heater Maintenance
90
Refrigeration System Maintenance
90
Suction Pressure
91
Exhaust Pressure
91
Eev
91
Air-Cooled Condenser
91
Compressor
91
Drainage System Maintenance
93
Troubleshooting
97
Fan Fault Diagnosis and Handling
97
Heating System Fault Diagnosis and Handling
98
Refrigeration System Fault Diagnosis and Handling
98
Appendix A: Display Screen Menu Structure
101
Appendix B: Alarm
103
Appendix C: Driver Alarm Code
105
Appendix D: Maintenance Inspection List
106
Appendix E: Hazardous Substances
108
Appendix F: Circuit Diagram
109
Appendix F1 CR025 Circuit Diagram
110
Appendix F2 CR035 Circuit Diagram
111
Appendix F3 CR045 Circuit Diagram
112
Appendix F4 CR036 Circuit Diagram
113
Appendix F5 CR066 Circuit Diagram
114
Advertisement
Related Products
Vertiv Liebert CRV CRD10 Series
Vertiv CR035
Vertiv CR065
Vertiv Liebert CR025
Vertiv Liebert CR045
Vertiv Liebert CRV CRD100-0D00A
Vertiv Liebert CRV CRD101-0D00A
Vertiv Liebert CR021RA
Vertiv Liebert CR011RA
Vertiv Liebert DM Series
Vertiv Categories
UPS
Power Supply
Switch
Power distribution unit
Air Conditioner
More Vertiv Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL