Sign In
Upload
Manuals
Brands
Tyco Manuals
Smoke Alarm
MX4428
Tyco MX4428 Fire Alarm System Manuals
Manuals and User Guides for Tyco MX4428 Fire Alarm System. We have
1
Tyco MX4428 Fire Alarm System manual available for free PDF download: Technical Manual
Tyco MX4428 Technical Manual (134 pages)
MXP ENGINEERING / TECHNICAL MANUAL
Brand:
Tyco
| Category:
Smoke Alarm
| Size: 0 MB
Table of Contents
Table of Contents
3
Amendment Log
2
End User Liability Disclaimer
2
Non-Disclosure Agreement
2
Trademarks
2
Table of Contents
3
Chapter 1 Introduction
7
About this Manual
8
Associated Documentation
8
Product Related
8
Standard Related
9
Specifications
9
Terminology
10
Chapter 2 Responder Loop Design Considerations
11
Mxp Application Considerations
12
Logical" Responders
13
Theory
13
Logical Responders
15
Point to Circuit to Zone Mapping
15
Implications to System Design
16
Chapter 3 Device Information and Programming
17
Device Types
18
MX Devices
18
Device Handling Capability
23
Overview
23
DC Load
24
Ac Loading
24
Isolator Base Loading
25
Example
25
Output Control
26
Programming
27
Output State under Exceptional Circumstances
27
Detector Parameter Settings Summary
28
Device Installation
29
Precautions
29
Mounting
29
Address & Led Blink Programming
29
Mx4428 Programming
30
814H Heat Detector
31
General
31
Specifications
31
Mx4428 Programming Options - 814H
31
814I Ionisation Smoke Detector
33
General
33
Specifications
33
Mx4428 Programming Options - 814I
33
814Ph Photoelectric Smoke & Heat Detector & 814P Photoelectric Smoke Only Detector
35
General
35
814Ph & 814P Specifications
35
Mx4428 Programming Options - 814Ph/814P
35
814Ch Carbon Monoxide + Heat Detector
39
General
39
814Ch Specifications
39
Mx4428 Programming Options - 814Ch
39
Mub Universal Base
41
General
41
Mub and 5B Wiring
41
Remote Indicator Wiring
41
5Bi Isolator Base
42
General
42
Specifications
42
Wiring
42
814Rb Relay Base
44
General
44
Specifications
44
Wiring
44
814Sb Sounder Base
46
General
47
Specifications
47
Mkii Sounder Base
47
Wiring
47
General
48
Mim800 and Mim801 Mini Input Modules
48
Mim800 / Mim801 Specifications
48
Field Wiring
49
Mx4428 Programming Options - Mim800 / Mim801
49
3.16.5 Mx4428 Programming Options - Mim801
50
Mx4428 Programming Options - Mim801
50
Cim800 Contact Input Module
51
Cim800 Specifications
51
General
51
Field Wiring
52
Mx4428 Programming Options - Cim800
52
Normally Closed
53
Normally Open Parameter Description Default Mode no Interrupt
53
Interrupt P0 Normal to Alarm Threshold
53
P0 Normal to S/C Threshold
53
P1 Normal to O/C Threshold
53
P2 Alarm to S/C Threshold
53
No Alarm Resistor
53
100 Ohm Alarm Resistor
53
P3 P4 P5 P6
53
Parameter Description Default
53
Cp820 Manual Call Point
54
General
54
Mx4428 Programming Options - Cp820
54
Parameter Description Default
54
Fp0838 / Fp0839 Manual Call Points
55
General
55
Mx4428 Programming Options - Fp0838 / Fp0839
55
Dim800 Detector Input Monitor
56
General
56
Dim800 Specifications
57
Dim800 Detector Compatibility
58
Mx4428 Programming Options - Dim800
58
Mode Value Description
58
General
59
Rim800 Field Wiring
59
Rim800 Relay Interface Module
59
Rim800 Specifications
59
Mx4428 Programming Options - Rim800
60
P0 P1 P2
60
General
61
Snm800 Sounder Notification Module
61
Snm800 Specifications
61
Mx4428 Programming Options - Snm800
62
Snm800 Field Wiring
62
General
63
Lps800 Loop Powered Sounder Module
63
Lps800 Specifications
63
Mx4428 Programming Options - Lps800
63
General
65
Vlc-800Mx Vesda Lasercompact
65
Vlc800 Specifications
65
Mx4428 Programming Options - Vlc800
66
Avf / Rad / Sad / Flowswitch Delays
67
Avf/Rad
67
Avf/Sad
67
Flowswitch
67
Sad
67
Chapter 4 Analogue Loop Design Considerations
69
Analogue Loop Configuration Selection
70
Lines & Loops
70
Loop Fault Tolerance
70
As1670.1 Design Requirements
70
Nzs4512 Design Requirements
70
Analogue Loop/Line Layouts
71
Line Mode
71
Loop Design with Short Circuit Isolators
71
Star Connection of Analogue Lines
73
Spurs
73
Cable Selection Considerations
74
Ac Requirements
75
General
75
DC Considerations
75
Mechanical Considerations
75
Noise Considerations
76
Chapter 5 Mxp Current Consumption
77
Theory
78
Alarm Current
78
Quiescent Current
79
Heat Loss
79
Chapter 6 Event Log and Status at Mx4428
81
Returned Analog Values
82
Fault and Alarm Event Log
83
Chapter 7 Mxp Technical Description
85
General
86
Circuit Description
87
Block Diagram
87
Microprocessor & Logic Circuitry
87
Mxp Power Supply
88
Mx4428 Loop Interface
90
Analogue Loop Interface
91
Mxp Adjustments
94
Iso Supply Voltage Adjustment
94
Tx Data Voltage Adjustment
94
Iso Supply Current Limit Adjustment
94
Mxp Led Indications
95
Parts List
96
Chapter 8 Mxp Diagnostic Terminal
99
Mxp Diagnostic Terminal Operation
100
Introduction
100
Menu of Commands
100
Selecting Points for Monitoring
100
Displaying Device Analogue Values - CV, Tv, Etc
101
St (Status Command)
103
Analog Loop Diagnostics
104
Advanced Commands
106
Mx4428 Diagnostics
106
Mxp Event Log
107
Flash Programming
108
Files Required
108
Procedure
108
Chapter 9 Device Processing
111
Exponential Filter
112
Step Limiting Filter
112
Heat Processing
114
Conversion of Detector Reading to °C
114
Photo Processing
116
Smartsense Processing
116
Smartsense Enhancement
116
Fastlogic Processing
117
Co Processing
118
Calibration and Temperature Compensation
118
Enhancement
118
Ionisation Processing
119
Mim800 / Cim800 / Mim801 Processing
120
Algorithm - Mim800, Cim800
121
Algorithm - Mim801
121
DIM Processing
122
Load Graph
122
DIM Model
122
Algorithm - Dim800
122
Supply Monitoring - Dim800
123
Rim Processing
123
Position Monitoring
123
Snm Processing
123
Programming
123
Supply Fault Determination
123
Eol and Position Monitoring
123
Lps Processing
124
Eld and Position Monitoring
124
Vlc800 Processing
124
General
124
Filter Step Limits
125
Zone Alarm Test
125
Zone Fault Test
125
Autotest and System Test
125
Non Latching Test Mode
126
Commission Mode
126
Fast Point Test
126
Slow Point Test
126
Summary of All Test Modes
126
Ancillary Filtering
127
Reset
128
Reset of Addressable Detector
128
Reset of DIM Module
128
Reset of Ancillary Input Device
128
Reset of Ancillary Output Device
128
Device Initialisation and Polling
129
Software Versions
130
Chapter 10 Mxp Loop Filter Board
131
Use of Mxp Loop Filter Board
132
Fitting
132
Diagnostics
133
Advertisement
Advertisement
Related Products
Tyco Vigilant MX1-Au
Tyco MX Series
Tyco MX2
Tyco VIGILANT MX 850EMT
Tyco Mastr III
Tyco MP-902 PG2
Tyco MZX125
Tyco Mini CERTI-LOK
Tyco MC-309 PG2
Tyco MINERVA MZX 250
Tyco Categories
Irrigation System
Control Unit
Security System
Security Sensors
Controller
More Tyco Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL