Sign In
Upload
Manuals
Brands
THORLABS Manuals
Controller
4000 Series
User Manuals: THORLABS 4000 Series Diode Controllers
Manuals and User Guides for THORLABS 4000 Series Diode Controllers. We have
1
THORLABS 4000 Series Diode Controllers manual available for free PDF download: Programmer's Reference Manual
THORLABS 4000 Series Programmer's Reference Manual (97 pages)
Brand:
THORLABS
| Category:
Controller
| Size: 3 MB
Table of Contents
Table of Contents
3
Foreword
6
1 General Information
7
2 Introduction to the SCPI Language
8
Syntax Conventions
8
Command Separators
9
Using the MIN, MAX and DEF Parameters
9
Querying Parameter Settings
10
Command Terminators
10
Parameter Types
10
Numeric Parameters
10
Discrete Parameters
11
Boolean Parameters
11
ASCII String Parameters
11
3 Commands by Subsystem
12
IEEE-488.2 Commands
12
IDN? - Identification Query
13
RST - Reset
13
SAV, *RCL, *SDS - Save/Recall Setup
14
TST? - Self Test
14
OPC, *OPC? - Operation Complete
14
WAI - Wait to Continue
15
Stb
15
Sre, *Sre
16
Cls
16
Esr?, *Ese, *Ese
16
System Subsystem Commands
18
Beeper
18
Error Query
18
Line Frequency
19
SCPI Version Query
19
Measurement Commands
20
Abort Measurement in Progres
24
Configuring a Measurement
24
Initiating a Measurement
26
Fetch a Measurement
26
Read Measurement Data
28
Simple Measurement
28
LD Output Commands
30
Output State
31
Switch-On Delay
31
Polarity
32
Noise Reduction Filter
32
Protection Voltage
33
Temperature Protection Mode
33
LD-ENABLE Input Mode
34
Protection Queries
35
PD Input Commands
36
Polarity
36
BIAS State
37
BIAS Voltage
37
Input Routing
38
Thermopile/Power Meter Input Commands
39
Input Routing
39
LD Source Commands
40
LD Source Function
42
LD Current Limit
42
LD Current Setpoint
43
LD Optical Power
43
LD Power Feedback
45
LD Amplitude Modulation
45
QCW Pulse Setting
46
PD Sense Commands
47
Photodiode Current Range
47
Photodiode Current Protection
48
Photodiode Responsivity
48
Photodiode Power Range
49
Photodiode Power Protection
49
Thermopile/Power Meter Sense Commands
49
Thermopile/Power Meter Voltage Range
50
Thermopile/Power Meter Voltage Protection
51
Thermopile/Power Meter Responsivity
51
Thermopile/Power Meter Power Range
52
Thermopile/Power Meter Power Protection
52
QCW Pulse Trigger Commands
53
QCW Trigger Source
53
TEC Source Commands
54
TEC Source Function
55
TEC Current Limit
56
TEC Current Setpoint
56
TEC Temperature Setpoint Limit
57
TEC Temperature Setpoint
57
PID Loop Constants
58
PID Auto Tune
58
Temperature Sense Commands
60
Sensor Selection
62
Thermistor Calculations
62
Transducer Offset
63
Temperature Protection
64
TEC Output Commands
65
Output State
65
Protection Queries
66
Status Subsystem Commands
67
Programming and Reading Registers
70
Auxiliary Register Group
71
Measurement Register Group
72
Questionable Register Group
73
Operation Registers Group
74
Status Preset Command
75
Memory Subsystem Commands
76
Number of State Memories
76
State Memories Names
76
Display Subsystem Commands
77
Display Brightness
77
Display Contrast
77
Digital I/O Output Commands
78
Digital I/O Output
78
Digital I/O Configuration
79
Digital I/O Input Commands
79
Digital I/O Input
80
Unit Subsystem Commands
81
Temperature Unit Commands
81
Calibration Subsystem Commands
82
Calibration String
82
4 SCPI Error Messages
83
Command Errors
84
Execution Errors
85
Device Specific Errors
86
Query Errors
86
Instrument Errors
87
5 Appendix
88
Instrument Default Settings
88
Copyright and Exclusion of Reliability
93
Thorlabs Worldwide Contacts
94
Advertisement
Advertisement
Related Products
THORLABS 4070
THORLABS 4070M-CL
THORLABS 4070C-GE
THORLABS 4070M-GE
THORLABS 4070C-CL
THORLABS APF503
THORLABS APF705
THORLABS APF710
THORLABS APT 600
THORLABS BBD101
THORLABS Categories
Measuring Instruments
Controller
Laboratory Equipment
Security Sensors
Industrial Equipment
More THORLABS Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL