User Manuals: ThermoFisher Scientific DXR xi Microscope
Manuals and User Guides for ThermoFisher Scientific DXR xi Microscope. We have
1
ThermoFisher Scientific DXR xi Microscope manual available for free PDF download: User Manual
ThermoFisher Scientific DXR xi User Manual (206 pages)
Raman Imaging Microscope with OMNICxi Raman Imaging Software
Brand:
ThermoFisher Scientific
| Category:
Microscope
| Size: 5 MB
Table of Contents
Table of Contents
3
About the System
7
Introducing the Dxrxi Raman Imaging System
7
Getting Started
8
Safety and Operating Precautions
8
About this Help System
9
Organization
9
Contacting Us
10
Conventions
10
Trademarks
11
Dxrxi Microscope Operation
13
Front View
15
Microscope Features and Controls
15
Right Side View
16
Left Side View
18
Inside Sample Compartment
19
Stage Controls
20
Indicators
21
Operating the Microscope
21
Loading a Sample
22
Powering the System up or down
22
Available Sample Holders
23
Rotating Stage Holder
25
Sample Holder Breadboard Kit with Clips
26
XPS Sample Holder
26
Leveling the Sample Holder
27
Raman Macro Sampler
27
Installing Objectives
31
Configuring Sample Illumination
32
Controlling Illumination with the Optional Reflected Light Brightfield
32
Controlling Illumination with the Optional Reflected Light Brightfield/Darkfield Illuminator
32
Illuminator
32
Controlling Transmitted Light Illumination
35
Using Optical Filters
35
Using Optical Polarizers
37
Positioning the Motorized Stage
45
Using Confocal Operation
46
Using the Raman Polarization Option
46
Changing the Laser, Filter, and Grating
47
Enabling the Laser
51
Installing a 633 Nm Laser
51
Optional Class 3B Laser Configuration
51
Using a Class 3B Fiber Optic Launcher Accessory
52
Installing the Microscope Alignment and Calibration Tool
54
Cleaning Your Instrument
57
Servicing the Microscope
57
Replacing an Illuminator Bulb
58
Replacing the Nosepiece
58
Laser Precautions
61
Safety Information
61
Biohazards or Radioactive Materials and Infectious Agents
62
Cooling Vents
62
Ventilation
63
Microscope Safety Labels
64
General Workflow
69
Omnicxi Software Operation
69
Omnicxi Acquisition Window
70
Overview of the Workspace
70
General Features and Controls
71
Image Cross Section Mode
71
Image Regions Mode
71
Live Spectrum Mode
71
Video Mode Features and Controls
71
Omnicxi Analysis Window
105
3D Analysis and Terrain Windows
116
Instrument Settings
122
Collect a Mosaic
126
Acquire and Analyze Data
131
Acquire a Preview Chemical Image
132
Analyze Regions
132
Settings for Acquiring a Chemical Image
133
Acquire and Analyze a Chemical Image
136
Profile Settings
137
Reanalyze Image Data
149
Identify and Analyze Particles
151
Video Image-Based Particle Analysis
151
Chemical Image-Based Particle Analysis
152
Settings for Particle Analysis
152
View Particle Analysis Results
155
View Spectrum at Specific Location
156
Analyze Sample Cross Sections
159
Measure Change over Time
165
View Time-Based Data
168
Acquire 3D Image Data
169
Measure and View 3D Volumes
169
Verify Instrument Performance
170
View 3D Data
170
Aligning and Calibrating Laser Sets
175
System Tools
175
Creating a New Video Calibration
180
Chapter 4 Troubleshooting
191
Problems and Solutions
191
Performance Verification Fails
191
Sample Bands Are too Small
192
Sample Bands Are too Large or CCD Overflowed
192
No Raman Signal Appears in the Live Display or Spectrum Has no Sample Bands
192
No Visible Image Appears in the Video Pane or Viewer
193
The Spectrum Has a Sloping Background or a Severe Positive Offset
193
The Spectrum Baseline Is Severely Tilted, Curved or Saturating
193
The Video Image Is Obscured or Distorted
194
The Computer Cannot Communicate with the Instrument
194
Chemical Image Appears to be Different than the Video Image
194
Chemical Image Does Not Achieve Required Spatial Resolution
195
Chemical Image Shows Missing Data
195
X-Axis Calibration Fails
195
Error Messages
196
General Errors
196
Instrument off or Disconnected
196
Video Camera Disconnected
197
Stage Controller off or Disconnected
197
Stage Controller Failed
198
Unknown Stage Location
198
Detector too Warm
198
Detector Disconnected
199
No Filter
199
No Grating
199
No Laser
199
Mismatched Grating
199
Mismatched Filter
199
Invalid Fiber Probe Configuration
200
Uncalibrated Laser, Grating, Filter Set
200
Alignment/Calibration out of Date
200
Stage Firmware out of Date
200
Sample Door Open
200
Laser off
200
Laser Key off
200
Laser Warming up
200
Sample Signal too High
201
Cannot Read Instrument EEPROM
201
No Communication
201
Align and Calibration Errors
201
Align/Calibrate Tool Not Connected
202
Laser Output too Low
202
No Laser at Sample
202
Poor Quality Align/Calibrate Spectra
203
Spectral Response too Low
204
Spectral Response too High
204
Performance Check Value(S) out of Range
205
Misaligned Filter or Grating
205
Unable to Read System Info
206
Unable to Collect Spectral Data
206
Unable to Calibrate Laser Power
206
Advertisement
Advertisement
Related Products
ThermoFisher Scientific DataTaker DT90 Series
ThermoFisher Scientific Data Taker DT90L
ThermoFisher Scientific Data Taker DT90N
ThermoFisher Scientific DeviceLink Connect
ThermoFisher Scientific SpeedVac DNA130
ThermoFisher Scientific 840-287100
ThermoFisher Scientific 840-287200
ThermoFisher Scientific 840-293700
ThermoFisher Scientific 912A0604
ThermoFisher Scientific 912A0605
ThermoFisher Scientific Categories
Laboratory Equipment
Measuring Instruments
Microscope
Data Loggers
Security Sensors
More ThermoFisher Scientific Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL