Sign In
Upload
Manuals
Brands
Sutron Manuals
Control Unit
AnalogPlus SDI-12 6661-1248-1
Sutron AnalogPlus SDI-12 6661-1248-1 Manuals
Manuals and User Guides for Sutron AnalogPlus SDI-12 6661-1248-1. We have
1
Sutron AnalogPlus SDI-12 6661-1248-1 manual available for free PDF download: Operation & Maintenance Manual
Sutron AnalogPlus SDI-12 6661-1248-1 Operation & Maintenance Manual (47 pages)
Brand:
Sutron
| Category:
Control Unit
| Size: 0 MB
Table of Contents
Table of Contents
3
1 Introduction
7
Features
7
2 Quick Start
8
3 SDI-12 Commands (Overview)
10
Setting the Address
10
Verifying the Address and Operation
11
Making a Measurement
12
Selecting a Measurement Command Class
12
Always Supported
12
Multiple Long Measurement Time Sensors
12
Improved Data Integrity Checking
12
Example: (M Command)
12
C, MC and CC Commands
13
Other Measurements
13
Factory Programmed Default Measurements
13
M, C, MC, CC
13
M1, C1, Mc1, Cc1
14
M2, C2, Mc2, Cc2
14
M3, C3, Mc3, Cc3
14
M4, C4, Mc4, Cc4
14
M5, C5, Mc5, Cc5
14
M6, C6, Mc6, Cc6
14
M7, C7, Mc7, Cc7
14
M8, C8, Mc8, Cc8
14
M9, C9, Mc9, Cc9
14
4 Measurements
15
Setting a Measurement (Quick Set-Up with Default Parameters)
15
Voltage Measurement (Single-Ended)
15
Voltage Measurement (Differential)
15
Ratiometric Measurement
15
Tipping-Bucket Measurement
16
Counts Measurement
16
Frequency Measurement
16
Period Measurement
16
Quadrature Shaft Encoder Measurement
17
Notes on Handar 436 Quadrature Ecoder (any Switch Closure Output Encoders)
17
State of Port
18
Setting a Measurement (Specific Set-Up with User-Defined Parameters)
19
Voltage Measurement
19
SDI-12 Set-Up Command
19
Examples
20
Verification and Reading Current Set-Up
20
Ratiometric Measurement
21
SDI-12 Set-Up Command
21
Examples
22
Verification and Reading Current Set-Up
22
Tipping-Bucket Measurement
23
SDI-12 Set-Up Command
23
Examples
23
Verification and Reading Current Set-Up
24
Count Measurement
24
SDI-12 Set-Up Command
24
Examples
24
Verification and Reading Current Set-Up
25
Frequency Measurement
25
SDI-12 Set-Up Command
25
Examples
25
Verification and Reading Current Set-Up
26
Period Measurement
26
SDI-12 Set-Up Command
26
Examples
26
Verification and Reading Current Set-Up
27
Quadrature Shaft Encoder Measurement
27
Offset
28
Scale-Factor
28
Direction of Rotation
28
Average, Minimum and Maximum Value/Measurement-Time
29
Status Byte
29
Verification and Reading Current Set-Up
29
State of Port
29
Example
29
Switched Voltage SW"D
30
Resetting to a Factory Default Configuration
30
5 Measurement Configuration Recommendations
31
Analog Measurement Parameters
31
Channel, Gain, Buffering
31
Averaging / Filtering
31
Vref Warm-Up Time
32
Switched Voltage and Switched Voltage Warm-Up Time
32
Example Setup Tutorials
32
AT/RH Probe
32
Continuously Powered
32
Powered for Measurements Only
33
Air Temperature Sensor
33
4-20Ma Output Sensor
34
6 Troubleshooting and Maintenance
35
Troubleshooting
35
Maintenance
35
7 Specifications for SDI-12 Analogplus Module
36
APPENDIX A -- Command Reference
37
APPENDIX B -- SDI-12 with the Sutron 8200, 8200A, and 8210
43
Entering Extended Commands for Configuration Purposes
43
From the Front Panel
43
From a PC Connected to the RS-232 Port
43
Logging Data from the M1 or M2 Commands or from Addresses above 9
43
Logging Data with Multiple Data Recorders
44
Setup Two Sutron Data Recorders with One SDI-12 Analogplus Module
44
Setup Two Sutron Data Recorders with Two SDI-12 Analogplus Modules
44
APPENDIX C -- Dimensions
45
APPENDIX D -- Sutron Customer Service Policy
46
APPENDIX E -- Commercial Warranty
47
Sutron Manufactured Equipment
47
Non-Sutron Manufactured Equipment
47
Repair and Return Policy
47
Extended Warranty and On-Site Maintenance
47
Advertisement
Advertisement
Related Products
Sutron 6661-1258-2
Sutron 6661-1258-3
Sutron 6661-1258-4
Sutron 6661-1249-1
Sutron Categories
Data Loggers
Modem
Touch Panel
Measuring Instruments
Controller
More Sutron Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL