Sign In
Upload
Manuals
Brands
Spacelabs Healthcare Manuals
Medical Equipment
Ultraview 91347-09
Spacelabs Healthcare Ultraview 91347-09 Manuals
Manuals and User Guides for Spacelabs Healthcare Ultraview 91347-09. We have
1
Spacelabs Healthcare Ultraview 91347-09 manual available for free PDF download: Service Manual
Spacelabs Healthcare Ultraview 91347-09 Service Manual (212 pages)
Brand:
Spacelabs Healthcare
| Category:
Medical Equipment
| Size: 8 MB
Table of Contents
Table of Contents
3
Introduction
9
Overview
9
System Components
11
Patient-Worn Transmitters (90341, 90347, 90343, 91341, 91343, 91347)
12
Selecting Options for the 90341/91341/91347 Lead Display
16
Multiparameter Transmission (90343/91343)
18
Battery Compartment SIP Switches
18
Additional Data Transmitted
20
Transmitter Batteries
20
Receiver Module (90478)
21
Receiver Electrical Requirements
23
Receiver Physical Dimensions
23
Receiver Housing (90479-A/B/C)
24
Receiver Housing Physical Dimensions
25
Receiver Housing Power Requirements
25
Receiver Housing Environmental Requirements
25
Operating
25
Storage
26
Receiver Housing Rear Panel
26
Setup
27
Unpacking
27
Unpacking the Patient-Worn Transmitter
28
To Unpack the Transmitter
28
Unpacking the Receiver Housing
29
To Unpack the Receiver Housing (Refer to the Drawing 12, Sheet 1 of 1)
29
Unpacking the Receiver
29
To Unpack the Receiver (Refer to Drawing 3, Sheet 2 of 2)
29
Receiver Housing Configuration
30
To Ready the 90479-A/B/C Receiver Housing for Operation
30
SDLC Configurations
32
AC Mains Voltage Selection
34
To Change the Voltage Selection
34
Fuse Replacement
35
To Replace AC Line Fuses for the Receiver Housing
35
Receiver Installation
35
To Install Receiver Modules into the Receiver Housing
35
Receiver Housing Power Operation
37
Patient-Worn Transmitter Configuration (90341, 90343, 90347)
38
Patient-Worn Transmitter Configuration (91341, 91343, 91347)
39
Changing the Default Settings
39
Units with Resistor Pack Programming
40
Units with SIP Switch Programming
42
Verifying Correct Frequency Operation
44
Antenna System Installation
45
Site Survey
45
Design
45
Installation
45
Verification
46
Tools for Tracking Transmitter Channels
46
Wideband and Narrowband Channel Coordination and Deployment
49
Wideband (50 Khz) Patient-Worn Transmitters
76
Narrowband (25 Khz) Patient-Worn Transmitter
82
VHF Telemetry Channel Frequencies
94
Theory
99
Patient-Worn Transmitters
99
Transmitter ECG PCBA Block Diagrams (90341, 90343, 90347, 91341, 91343, and 91347)
100
Transmitter ECG PCBA Description
101
Input Protection
101
Lead Drive Switches
101
Input Buffers
101
Lead off Comparators
102
Differential Amplifiers
102
Pacer Blanking Switches
102
Bessel Filter
102
Final ECG Amplifiers
102
DC Restoration Comparators
102
Pacer Detection and Pacer Flag Generator
102
Automatic Lead Switching PAL
102
Transmitter RF PCBA Block Diagrams (90341, 90343, 90347)
103
Transmitter RF PCBA Description (90341, 90343, 90347)
106
Status Mux
106
ECG Mux
106
Pwm Pal
106
PWM Ramp Generator
106
PWM Comparator
106
PWM Data Formatter
106
PWM Filter
106
Voltage Controlled Crystal Oscillator
107
First and Second Frequency Doublers
107
Transmitter RF PCBA Block Diagrams (91341, 91343, 91347)
107
Transmitter RF PCBA Description (91341/91343/91347)
109
Rf Pcba
109
Microcontroller
112
Configuration SIP Switches
112
Transmitter Spo 2 PCBA Description (90343/91343 Only)
114
Definitions and Acronyms
114
Electrical Requirements
114
Pulse Oximetry Sensor Drive
115
NIBP Interface (Spo 2 to ABP)
115
Patient Isolation
115
Functional Descriptions
115
Receiver Module
119
Receiver Signal Flow
120
CPU (80C186) PCBA Description
121
Watchdog/Power Reset
121
SDLC Mainframe Interface
121
RUPI/80C186 Interface
122
ECG Data Interface
122
High-Level Outputs and Defibrillator Sync Input
122
Configuration EEPROM
123
Front Panel LED Indicators
123
Power Supply PCBA
124
Antenna PCBA
124
Rf Pcba
124
Digital PCBA
124
Modular Receiver Housing
125
RF Signals
125
90479-A Modular Receiver Housing
125
90479-B/C Modular Receiver Housing
126
Analog Output
126
Power Supply
126
Power Supply Functional Description
127
AC Input Module
127
AC Input Rectifier and Filter
127
100 Khz DC-To-DC
128
Switcher Feedback Power
128
Gate Drive Transformer
128
Main Isolation Transformer
128
Secondary Side
128
Battery Disconnect
128
Over/Under Voltage Shutdown
129
DC On/Off
129
+5 V, +12 V, and -12 V DC-To-DC Converter
129
LED/AC Operation
129
Antenna Systems
129
Antenna Distance and Power Loss
129
Path Loss
130
Diversity Antenna System
130
Maintenance
133
Overview
133
Cleaning/Disinfecting
134
Physical Inspection
135
Transmitter
135
Receivers
135
Housing
135
Antenna System Inspection
136
Preventive Maintenance
136
Antenna System
136
Test Equipment Required
136
Verification
136
Safety Verification
137
Current Leakage Measurements (90479-A/B/C Only)
138
Battery Backup Test
138
To Conduct the Module Housing Battery Backup Test
138
Battery Disposal
139
Disassembly/Assembly of the Receiver Module
139
Disassembling the Receiver Module
140
Assembling the Receiver Module
142
Disassembling/Assembling the Module Housing
142
Battery Replacement
142
To Replace the Internal Power Backup Battery
142
Top Cover Removal
143
To Remove the Module Housing Top Cover
143
Power Supply Removal
143
To Remove the Power Supply from the Module Housing
143
RF Amplifier Removal
144
To Remove the RF Amplifier PCBA
144
Disassembling the 90347 and 90341 Transmitters
144
To Remove the ECG and Transmitter Pcbas
144
Assembling the 90347 and 90341 Transmitters
146
To Replace the ECG and Transmitter Pcbas
146
Disassembling the 90343 Transmitter
146
To Remove the ECG, Transmitter, and Spo Pcbas
148
Assembling the 90343 Transmitter
148
To Replace the ECG, Transmitter, and Spo Pcbas
148
ECG Performance Test
149
Spo Performance Test
150
Disassembling and Reassembling the 91341/91347 Transmitter
152
Disassembling and Reassembling the 91343 Transmitter
154
Transmitter Field Alignment Procedures
156
Definitions
156
Test Equipment Required
157
Initial Equipment Setup
157
Equipment Setup
157
Power-Regulated Current Drain Test
159
First Current Drain Test
159
Crystal Oscillator Test
159
Power Output Adjustment
160
Assigned Frequency Alignment
160
Final Current Drain Test
161
Transmitter Alignment Procedures
161
Power Output Test and Center Frequency Adjustment for Models 90341, 90343, and 90347
161
Power Output Test
161
Center Frequency Adjustment
162
Output Power Test and Center Frequency Tests for Models 91341-09, 91343-09, and 91347-09
165
Equipment Required
166
Output Test
167
To Verify Transmitter Power Ouput
167
Verify Center Frequency, Model 91341-09
168
To Verify Transmitter Center Frequency
168
Verify Center Frequency, Models 91343-09 and 91347-09
168
Field Current Drain Test
169
Initial Test Setup for 90341, 90347, 90343, 91341, 91343, and 91347 Transmitters
170
Current Drain Test for 90341 and 90347 Transmitters
171
Current Drain Test for 90343 Transmitters
171
Current Drain Test for 91341/91343/91347 Transmitters
172
Troubleshooting
173
Diagnostics
173
Receiver Self-Test
173
Receiver Leds
173
Patient-Worn Transmitter
175
Touchscreen Messages and Troubleshooting Guide
175
ECG Alarm Message Summary
176
Check XX
176
Abnormal/Minute Alarm
176
Asystole
176
Couplet Alarm
176
Ecg Alarms off
176
Ecg Alarms Suspended
176
Ecg Processing Suspended
177
Ecg Voltage too Low
177
Hi Rate Alarm
177
In Learn
177
Chan 1 & 2 Leads off
177
Chan 1 Leads off
177
Chan 2 Leads off
177
Lo Rate Alarm
177
New Dominant
178
Noisy Signal
178
Run Alarm
178
Fib
178
Spo 2 Alarm Message Summary
178
Adapter Disconnected - Check Connection at Module
179
Sensor Disconnected - Check Connection at Adapter Cable
179
Sensor off Patient - Check Connection at Patient
180
Faulty Sensor - Replace Sensor
180
Ambient Light Interference - Cover Sensor Area
180
Insufficient Signal - Reposition or Replace Sensor
180
Noisy Signal
180
NIBP Alarm Message Summary
180
NIBP UNAVAILABLE (XX)
181
NIBP READING FAILURE (XX)
181
Nibp Air Leak
181
Nibp Loose or no Cuff
181
Nibp Reading Cancelled
181
Nibp Low Battery
181
Nibp Kinked Hose
181
NIBP EVENT CODE (XX)
181
Telemetry Radio Frequency Problem Solving
182
Frequent Squelch
182
90479-A Receiver Housing
182
90479-B/C Receiver Housing
183
Signal Interference
183
Reducing Squelch
183
Use of RF Performance Statistics
184
Squelch Statistics Menu
185
Receiver Does Not Display an ECG Trace
186
Specific Receiver will Not Sign on to Monitor
186
No Receiver Signs on to Monitor
187
Power Supply Voltage Measurements (90479-A/B/C)
188
Parts
189
Overview
189
Assembly Drawings
189
A Appendix A - Electromagnetic Compatibility
191
Electromagnetic Emissions
191
Electromagnetic Immunity
192
Frequency Separation Distances
193
Left Ventricular Assist Device (LVAD
194
Command Module (91496
194
To Turn Pacer Detection off
194
Telemetry
194
Appendix B - Symbols
195
Advertisement
Advertisement
Related Products
Spacelabs Healthcare Ultraview 91341-09
Spacelabs Healthcare Ultraview 91343-09
Spacelabs Healthcare Ultraview 90347
Spacelabs Healthcare Ultraview 90343
Spacelabs Healthcare Ultraview 90478
Spacelabs Healthcare Ultraview 90479-A
Spacelabs Healthcare 93300-05
Spacelabs Healthcare 93300-05I
Spacelabs Healthcare 93300-05IC
Spacelabs Healthcare 93300-05E
Spacelabs Healthcare Categories
Medical Equipment
Blood Pressure Monitor
Monitor
Transmitter
Measuring Instruments
More Spacelabs Healthcare Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL