Sign In
Upload
Manuals
Brands
Smartlock Digital Manuals
Locks
Axessor CIT
Smartlock Digital Axessor CIT Safe Lock Manuals
Manuals and User Guides for Smartlock Digital Axessor CIT Safe Lock. We have
1
Smartlock Digital Axessor CIT Safe Lock manual available for free PDF download: Operating Manual
Smartlock Digital Axessor CIT Operating Manual (114 pages)
Brand:
Smartlock Digital
| Category:
Locks
| Size: 7 MB
Table of Contents
Table of Contents
4
1 Introduction
9
To the very Beginning
9
Notes Regarding the Operating Manual
9
Validity
9
Target Group
9
Limitation
9
Supplementary Documentation
9
Symbols Used in this Operating Manual
10
Text Marking
10
2 Safety and Environment
11
General
11
Qualification of Personnel
11
Prohibited Modifications to the Unit
11
Environment
11
3 Product Overview
12
Product Description
12
Field of Application
14
Intended Use
14
Operating Modes of the Axessor CIT
14
System Components
17
Axessor CIT Lock
17
AS280-INSW Activation Software
17
AS284-USBW or AS284-NETW Programming Software
17
AS274 Server Management Software
17
APHI (Application Programming Hardware Interface)
17
4 Installation
18
Important Information Prior to the Installation
18
Unpacking and Checking the Delivery
18
Installing the Input Unit
19
Installing the Lock
24
Perform Wiring Check after Lock Installation
26
External Connections at the Lock
27
Installing the Ebox
29
External Connections at the Ebox
30
Perform Wiring Check after Ebox Installation
32
Operating
33
Operating and Display Elements of the Input Unit
33
Programming Mode
34
Operating Modes
34
Immediate Time Lock
34
Information Menu
35
Buzzer Signals
36
Status Messages
36
Locked (Mode S)
36
Locked (Mode I)
36
Open (Modes S and I)
37
Immediate Time Lock (Modes S and I)
37
Weekly Time Lock (Modes S and I)
37
Holiday Time Lock (Modes S and I)
37
Ready for Entry of Combination (Mode I)
37
Entry of the Opening Combination (Mode I - OTC)
37
Entry of the Opening Combination (Mode I - ICS)
37
The Close Seal Is Displayed (Mode I)
38
Post-Access Delay (Modes S and I)
38
Opening Time Delay (Mode I)
38
Opening Time Delay (Mode S)
38
Confirmation after Elapse of Time Delay (Mode S)
39
Enter Second Code - Dual Mode Activated (Mode S)
39
Penalty after Wrong Trials (Mode S and I)
40
Remote Disabling (Mode S and I)
40
Remote Enabling (Mode S and I)
40
Identification with Denied Code / Non Return Time Delay Enga- Ged (Mode S)
40
The Battery Compartment Has Been Opened (Mode S and I)
41
Connected with Programming Software (Mode S and I)
41
External Power Supply Available (Mode S and I)
41
Access Codes
42
Code Hierarchy and Code Formats
42
Code Types
42
Master Code
43
Manager Codes
43
User Codes
44
Courier Code
45
Shelve Function
45
Duress Code
45
Duress Code in Bank Mode
45
Duress Code in Interactive Mode
46
Code Entry
47
Opening Procedure
48
Opening Procedure in Bank Mode
48
Opening Procedure in ICS Mode
50
Opening Procedure in OTC Mode
51
Closing Procedure
52
Closing Procedure in Bank Mode
52
Closing Procedure in Interactive Mode
52
Programming Mode
53
Operating the Programming Mode
53
Activating the Programming Mode
53
Navigating in the Programming Mode
54
Modify and Save Settings in the Programming Mode
54
Exiting the Programming Mode
55
Menu Overview
56
Access Rights
57
Programming
58
Menu TIME
58
Setting the Time - Submenu TIME
58
Setting the Time - Submenu DATE
59
Setting the Time Format - Submenu AM/PM
60
Setting the Daylight Saving Time - Submenu DST
60
Menu PROG
61
Activating an Immediate Time Lock - Submenu IMM-TL
61
Configuring Weekly Locking Periods - Submenu WEEKLY
62
Adding a Weekly Locking Period
62
Modifying an Existing Weekly Locking Period
63
Deleting an Existing Weekly Locking Period
63
Configuring Holiday Locking Periods - Submenu HOLIDAY
64
Adding a Holiday Locking Period
64
Modifying an Existing Holiday Locking Period
65
Deleting an Existing Holiday Locking Period
65
Configuring Time Lock Interruption - Submenu TL-INT
66
Adding a Time Lock Interruption
66
Modifying an Existing Time Lock Interruption Period
67
Deleting an Existing Time Lock Interruption Period
67
Adding a Time Related Function
68
Configuring Time Related Function - Submenu TR-FNC1
68
Deleting an Existing Time Related Function
70
Menu DELAY
71
Modifying an Existing Time Related Function
70
Setting/Deactivating Time Delays - Submenus DELAY 1
71
Configuring the Confirmation Window - Submenu CNF WIN
73
Configuring the Non Return Time Delay - Submenu NRTD HM
74
Configuring the Opening Delay of Duress Alarm - Submenu D-ALARM
74
Configuring the Bolt Open Time for Bank Mode - Submenu BLT OPN Bank
75
Configuring the Window to Enter Second Code in Dual Mode - Submenu DUAL Bank
75
Configuring the Bolt Open Time for CIT Mode - Submenu BLT OPN Cit
76
Configuring the Window to Enter a One Time Code - Submenu PROCTIM Cit
77
Setting OTM Time Delay - Submenus DELAY Cit
77
Configuring the Opening Delay of OTM Duress Alarm - Submenu DURESS Cit
78
Menu CODE
79
Changing the Master Code - Submenu MASTER
79
Setting Manager Codes - Submenu MANAGER
80
Setting User Codes - Submenu USER
81
Setting the Courier Code - Submenu COURIER
83
Reset the Whole Axessor CIT Safe Lock System to Factory Defaults - Submenu SHELVE
84
Modifying a Code
85
Deleting a Code
86
Menu MISC
87
Enabling/Disabling Remote Disable - Submenu RMT-DIS
87
Setting the Display Language - Submenu LANG
87
Enabling/Disabling Open Beeper - Submenu OPEN Beep
88
Setting the Beeper Volume - Submenu Volume
88
Enabling/Disabling Confirmation Window Beeper - Submenu CNF WIN Beep
89
Enabling/Disabling Delay Notify Beeper - Submenu DELAY Beep
89
Enabling/Disabling Duress Delay Notify Beeper - Submenu D-ALARM Beep
90
Enabling/Disabling Wait Time Display - Submenu WAIT Info
90
Activating/Deactivating Code Denial - Submenu CDE den Bank
91
Enabling/Disabling Language in Display - Submenu LANG Info
91
Activating/Deactivating Duress Code Function
92
Submenu DURESS Bank
92
Activating/Deactivating Dual Mode - Submenu DUAL Bank
93
Enabling/Disabling Time Lock for OTM - Submenu TL LOCK Cit
95
Enabling/Disabling Non Return Time Delay - Submenu NRTD Cit
95
Display the Current Time - Submenu TIME Cit
96
7 Servicing
97
Cleaning
97
Replacing the Batteries
97
Customer Service
98
Spare Parts and Accessories
99
8 Error Messages
100
9 Technical Data
103
Functions
103
Electronics
106
Mechanics
107
Approvals and Certificates
108
Factory Settings
109
Advertisement
Advertisement
Related Products
Smartlock Digital Axessor USB
Smartlock Digital LG Master
Smartlock Digital Categories
Locks
Keypad
More Smartlock Digital Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL