SIGRIST ScrubberGuard 121570 Instrument Manuals
Manuals and User Guides for SIGRIST ScrubberGuard 121570 Instrument. We have
1
SIGRIST ScrubberGuard 121570 Instrument manual available for free PDF download: Instruction Manual
SIGRIST ScrubberGuard 121570 Instruction Manual (126 pages)
Monitoring of exhaust gas cleaning system wash water
Brand:
SIGRIST
| Category:
Measuring Instruments
| Size: 5 MB
Table of Contents
Table of Contents
3
1 General User Information
7
Terms Used in this Document (Glossary)
7
Purpose of the Instruction Manual
7
Target Group of the Documentation
7
Additional Documentation
7
Copyright Provisions
7
Document Storage Location
8
Order Document
8
Proper Use
8
User Requirements
8
Declaration of Conformity
8
Use Restrictions
8
Removing the Casing from the Scrubberguard
9
Dangers When Not Used Properly
10
Meaning of the Safety Symbols
10
Meaning of the Pictograms
11
2 Instrument Overview
12
Overview of the Scrubberguard
12
Designation of the Instruments
13
Designation of the Scrubberguard
13
Designation of the Scrubbercontroller
14
Designation of the Aquascat SG (A)
15
Designation of the Oilguard SG (A)
16
Scope of Supply and Accessories
16
Standard Scope of Supply for the Scrubberguard
16
Optional Accessories for the Scrubberguard
18
Technical Data for the Scrubberguard
19
General Technical Data
19
Technical Data for the Aquascat SG (A)
20
Technical Data for the Oilguard SG (A)
21
Technical Data for the Ph Sensor
21
3 General Safety Points
22
Dangers When Properly Used
22
Danger Due to UV Radiation
23
Storing the Calibration Aids
23
Checking Unit
23
Calibration Solutions
24
Residual Risk
24
Warning and Danger Symbols on the Instrument
25
Preventing Undesirable Online Access Attempts
25
4 Mounting
26
Location Selection
26
Setting up (Mounting) the Scrubberguard
26
Mounting the Standard Accessories
28
Mounting the Ph Sensor
28
Mounting the Sample Connections
31
Mounting the Optional Accessories
32
Mounting the Additional Deaeration Tubes
32
Retrofitting the Solenoid Valves for Higher Temperatures
32
5 Electrical Installation
33
Safety Pointers for the Electrical Connection
33
Opening/Closing the Cabinet
34
Connecting the Service Voltage in the Cabinet
35
Connecting the Customer Connections in the Cabinet
36
Connecting the Field Bus Interfaces (Optional)
38
Removing the Front Cover of the Photometer
38
Overview of Profibus DP and Modbus RTU
39
Connecting the Modbus RTU or Profibus DP
40
Overview of Profinet IO
41
Overview of HART
42
Connecting to HART
42
Connecting the Modbus TCP
43
6 Commissioning
44
7 Operation
47
Control Elements of the Scrubberguard on the Cabinet
47
Operation Basics
48
Control Elements in Measuring Mode
48
Menu Button
49
Valu Button
49
Info Button
49
Info Button, Screen 1
49
Info Button
50
Diag Button
51
Functions of the Log Screen (Log Button)
52
Displays in Measuring Mode
53
Lock / Unlock the Touch Screen
54
Switching to Service Mode
55
Control Components in Service Mode
56
Input Elements in Service Operation
56
Numerical Entry
57
Single Selection of Functions
58
Multiple Selection of Functions
58
8 Settings
59
Setting the Operating Language
59
Setting the Current Outputs
60
Setting the Limits
61
Upper and Lower Threshold Value of a Limit
62
Reading if Limit Exceeded or Undershot
62
Set Outputs
63
Setting the Date and Time
64
Entering or Changing the Access Code
65
Back up Configured Data
66
9 Servicing
67
Servicing Schedule for the Scrubberguard
67
Servicing Duties on the System
68
Scrubberguard Checklist
68
Checking the Flow Rate on the System
71
Cleaning the Water Tank
73
Cleaning the Deaeration Tubes
76
Replacing the Tension Springs on the Scrubberguard
77
Replacing the Rubber Buffer
78
Replacing the Float Switch in the Water Tank
81
Replacing the Impeller Set on the Inlet Pump and Outlet Pump
84
Replacing the Pump Capacitor
87
Replacing the Instrument Pumps
89
Replacing the Solenoid Valves
91
Servicing Duties on the Ph Sensor
94
General Handling of the Ph Sensor
94
Cleaning and Calibrating the Ph Sensor
96
Replacing Ph Sensors that Have Been Configured by SIGRIST
98
Installing an Unconfigured Ph Sensor
98
Servicing Duties on the Photometers
100
Placing the Optics Unit in the Recess (Dockingstation)
100
Checking the Flow Rate and Cleanliness of the Measuring Instruments
101
Manual Adjustment
104
Cleaning Parts Which Come into Contact with Water
106
Replacing the Air Filter
108
Replacing the Battery
109
10 Troubleshooting
110
Pinpointing Faults
110
Warning Messages and Effect on Operation
110
Fault Messages and Effect on Operation
112
Prioritized Fault Messages and Their Effect on Operation
114
Checking the Circuit Breakers for the Pumps
115
11 Repair Work
116
Replacing the Microfuses
116
12 Customer Service Information
117
13 Decommissioning/Storage
118
Decommissioning the Scrubberguard
118
Storing the Components
119
14 Packaging / Transport / Returning
120
15 Disposal
121
16 Spare Parts List
122
Spare Parts for the Scrubberguard
122
17 Index
124
Advertisement
Advertisement
Related Products
SIGRIST ScrubberGuard 121290
SIGRIST ScrubberGuard 121435
SIGRIST ScrubberGuard 121440
SIGRIST ScrubberGuard 121445
SIGRIST ScrubberGuard 121575
SIGRIST ScrubberGuard 121580
SIGRIST ScrubberGuard 121585
SIGRIST 118992
SIGRIST 118993
SIGRIST 118994
SIGRIST Categories
Measuring Instruments
Smoke Alarm
Industrial Equipment
Monitor
Control Unit
More SIGRIST Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL