Sign In
Upload
Manuals
Brands
SIGLENT Manuals
Test Equipment
SDS-2000X-LA
SIGLENT SDS-2000X-LA Manuals
Manuals and User Guides for SIGLENT SDS-2000X-LA. We have
1
SIGLENT SDS-2000X-LA manual available for free PDF download: User Manual
SIGLENT SDS-2000X-LA User Manual (250 pages)
Digital Oscilloscope
Brand:
SIGLENT
| Category:
Test Equipment
| Size: 5.92 MB
Table of Contents
Safety Information
4
Safety Terms and Symbols
6
Measurement Category
7
Working Environment
8
Ventilation Requirement
9
General Care and Cleaning
10
Document Overview
19
Table of Contents
21
Quick Start
31
General Inspection
32
Appearance and Dimensions
33
To Prepare the Oscilloscope for Use
34
To Adjust the Supporting Legs
34
To Connect to Power Supply
35
Power-On Inspection
36
To Connect the Probe
37
Functional Inspection
38
Probe Compensation
39
The Front Panel
40
The Rear Panel
41
Front Panel Function Overview
42
Horizontal
42
Vertical
43
Trigger
45
Run Control
46
Universal Knob
47
Menu
48
Help
49
User Interface
50
To Use the Security Lock
52
To Set the Vertical System
53
To Enable the Channel
54
To Adjust the Vertical Scale
55
To Adjust the Vertical Position
55
To Specify Channel Coupling
56
To Specify Bandwidth Limit
56
To Specify Probe Attenuation Factor
57
To Specify Channel Input Impedance
57
To Specify Amplitude Unit
58
To Invert a Waveform
58
Set the Horizontal System
59
Adjust the Horizontal Scale
60
Adjust Trigger Delay
61
Set the Roll Mode
62
Use the Zoom Function
63
To Set the Sample System
64
Run Control
65
Overview of Sampling
66
Sampling Theory
66
Sample Rate
67
Oscilloscope Bandwidth and Sample Rate
68
To Specify Memory Depth
69
To Select Sampling Mode
69
To Select Waveform Interpolation Method
70
To Select Acquisition Mode
72
Normal
72
Peak Detect
73
Average
74
Eres (Enhanced Resolution)
75
To Change the Horizontal Format
76
Use Sequence Mode
77
To Trigger the Oscilloscope
79
Trigger Source
81
Trigger Mode
82
Trigger Level
83
Trigger Coupling
84
Trigger Holdoff
85
Noise Rejection
86
Trigger Type
88
Edge Trigger
89
Slope Trigger
90
Pulse Trigger
92
Video Trigger
94
Window Trigger
97
Interval Trigger
100
Dropout Trigger
102
Runt Trigger
104
Pattern Trigger
106
Serial Trigger and Decode
108
IIC Trigger and Serial Decode
109
Setup for IIC Signals
109
IIC Triggering
111
IIC Serial Decode
115
SPI Triggering and Serial Decode
117
Setup for SPI Signals
117
SPI Triggering
120
SPI Serial Decode
122
UART/RS232 Trigger and Serial Decode
124
Setup for UART/RS232 Signals
124
UART/RS232 Triggering
126
UART/RS232 Serial Decode
128
CAN Trigger and Serial Decode
130
Setup for CAN Signals
130
CAN Triggering
132
CAN Serial Decode
134
LIN Triggering and Serial Decode
136
Setup for LIN Signals
136
LIN Triggering
137
LIN Serial Decode
139
Digital Channels
141
To Connect the Digital Probes to the Device-Under-Test
142
Acquiring Waveform Using the Digital Channels
143
To Change the Display Type of the Digital Channels
143
To Switch a Single Channel on or off
145
To Switch All Digital Channels on or off
145
To Change the Logic Threshold for Digital Channels
145
To Reposition a Digital Channel
146
To Display Digital Channels as a Bus
146
To Save Reference Waveform
148
To Save REF Waveform to Internal Memory
149
To Display REF Waveform
149
To Adjust REF Waveform Display
150
To Clear REF Waveform Display
150
To Use the Math Operation
151
Units for Math Waveforms
152
Math Operators
153
Addition or Subtraction
153
Multiplication and Division
154
FFT Operation
155
Differentiate
159
Integrate
160
Square Root
161
To Adjust the Math Waveform Scale and Offset
162
To Adjust the Math Waveform Horizontal Scale and Offset
162
To Adjust the Math Waveform Vertical Scale and Offset
162
To Make Cursor Measurements
163
Cursors
163
Y Cursors
163
To Make Cursor Measurements
164
To Make Measurements
165
Type of Measurement
166
Voltage Measurements
166
Time Measurements
168
Delay Measurements
169
To Make Automatic Measurements
170
To Clear Measurement Parameters
172
To Make All Measurement
172
Display Setting
173
To Set Display Type
174
To Set Color Display
175
To Set and Clear Persistence
175
To Clear the Display
176
To Select Grid Type
177
To Adjust Waveform Intensity
177
To Adjust Grid Brightness
179
To Adjust Transparence
179
Save and Recall
180
Save Type
181
Internal Save and Recall
182
External Save and Recall
183
Disk Management
186
To Create a New File or Folder
187
To Delete a File or Folder
188
To Rename a File or a Folder
188
System Function Setting
189
To View the System Status
190
To Do Self-Calibration
191
To Enable or Disable the Sound
192
To Specify the Language
192
To Enable Pass/Fail Test
193
To Set and Perform Pass/Fail Test
194
To Save and Recall Test Mask
195
I/O Set
197
To Set the USB Device
197
To Set the LAN
198
To Set aux Output
199
To Do Power Analysis
200
To Perform Channel Deskew
201
Perform Power Analysis
203
To Enable Quick-Cal
227
To Update Firmware and Configuration
228
To Perform a Self-Test
229
Advertisement
Advertisement
Related Products
SIGLENT SDS2000X Series
SIGLENT SDS2000 Series
SIGLENT SDS2000X-E Series
SIGLENT SDS2000X Plus Series
SIGLENT SDS2074X Plus
SIGLENT SDS2072X Plus
SIGLENT SDS-2000X-FG
SIGLENT SDS2502X Plus
SIGLENT SDS2354X Plus
SIGLENT SDS2354X HD
SIGLENT Categories
Test Equipment
Portable Generator
Measuring Instruments
Power Supply
Multimeter
More SIGLENT Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL