Sign In
Upload
Manuals
Brands
Sievers Manuals
Measuring Instruments
TOC 810
Sievers TOC 810 Manuals
Manuals and User Guides for Sievers TOC 810. We have
1
Sievers TOC 810 manual available for free PDF download: Operation And Maintenance Manual
Sievers TOC 810 Operation And Maintenance Manual (255 pages)
800 Series Total Organic Carbon Analyzer
Brand:
Sievers
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Identification Records
2
Revision History
3
Trademarks and Patents
4
Confidentiality
4
Standard Limited Warranty
5
Declaration of Conformity
6
Table of Contents
7
1 Introduction
13
Warnings - English
14
Warnings - Español
15
Warnings - Francais
16
Warnings - Deutsch
17
Warnings - Italiano
18
Warnings - Dutch
19
2 System Specifications
23
3 System Description
25
Sample Inlet Systems and Sample Pump
27
On-Line Sampling from Pressurized Source
27
Grab Sampling
27
Calibration Valve
28
Chemical Reagent Reservoirs
28
Chemical Reagent Syringe Pumps
29
Stream Splitter
29
Oxidation Reactor
30
CO 2 Sensors
30
DI Water Loop
31
Membrane Module
31
Conductivity and Temperature Measurement Cell
31
Microprocessor Controller and Electronics
32
On-Board Data Storage
32
Data Outputs
33
CO 2 Sensor Measurement Cycle
33
Major Accessories and Configurations Available for the Analyzer
34
IC Removal Module
34
Autosampler
34
Multistream
35
Turbo
36
Flow Switch and Binary Input Module
36
Ozone Destruct Kit
36
Environmental Enclosure
36
Front Panel Displays and Controls
37
4 Installation
39
Unpacking and Inspecting
39
Collecting Additional Equipment
40
Site Selection/Location
41
Power Requirements
41
Environmental Consideration
41
Installing Sample Port
41
Plumbing
42
Installing On-Line Sample Inlet System
42
Installing Grab Sample Inlet System
43
Electrical
46
Installing the Recorder, Alarm, and Printer Cables - Wiring
46
Recorder and Alarm Outputs
47
Table 1. Analog Outputs on Terminal Strip
48
Printer Cable
49
Installing Reagent Cartridges
49
Selecting the Sample Mode
52
Entering the Date and Time
55
Enter the Installation Dates for Reagents
55
Oxidizer Reagent
56
Acid Reagent
58
Selecting Oxidizer and Acid Flow Rates
59
Table 2. Recommended Reagent Flow Rates
61
Preset Flow Rates
62
Table 3. Preset Acid and Oxidizer Flow Rates
62
Manual/Grab Flow Rates
64
Setting up a Password
67
Entering Printer Setup
68
Print Interval
69
Print Constants
69
Reagent Flush
72
5 Analog and Digital Outputs
75
Baud Rate
75
RS-232 Data out
76
Table 4. RS-232 Data Output Format
77
Serial Commands
79
Alarms
81
Analog Outputs
83
Display
85
Warning 42
86
6 Operation and Display Menus
88
Menu Map
89
Main Menu
89
Measurement Display
92
Runtime Menu
93
Errors
93
Stop TOC
93
Table 5. Operating Messages
93
Viewing Consumables Status
97
UV Lamp Status
98
Reagent Status
99
Fatal Error Display
101
Turning off Power to the Analyzer
101
Grab Sample Measurements
102
Setting the Sample Mode to Grab Sampling
103
Changing from On-Line to Grab Sampling
104
Setting up the Grab Sample Mode
104
Running Grab Samples
109
Changing to or Returning to On-Line Measurements
111
Changing the Password
113
Disabling Password Protection
116
Service Menu
116
7 Dataguard Operation
117
Menu Map
118
Main Menu
119
Runtime Menu
119
Stop TOC Option
120
Setup
121
Admin
122
Password
122
Table 6. User Ids
123
Entering a Password
124
Setting a Password
125
Disabling a Password
127
Login Timeout
127
Audit Trail
128
View Audit Trail
129
Print Audit Trail
129
Export Audit Trail
129
Table 7. RS-232 Audit Trail Output Format
132
Reset Audit Trail
133
Logging out
133
8 Maintenance
135
Table 8. Replacement/Maintenance Schedule
135
Replacing the In-Line Filter
136
Table 9. Available RAM Cards and Storage Capacity
136
Replacing the Reagents
138
Replacing the UV Lamp
142
Replacing the Pump Tubing
146
Entering the Installation Dates for Reagents, UV Lamp, and Pump Tubing
149
Oxidizer Reagent
150
Acid Reagent
152
Lamp
153
Pump Tubing
154
Checking and Refilling the DI Water Reservoir
156
Cleaning the Analyzer
157
9 Calibration
159
Supplies for TC and IC Standards
160
TC Zero Offset
170
TC Calibration Constant
170
IC Calibration Constant
173
TC and IC Calibration Verification
177
10 Troubleshooting
185
Checking the Error Stack
185
Table 10. Warnings and Error Messages
187
Corrective Actions
188
Printing the Error Stack
193
No Power to the Analyzer
194
No Flow through the Analyzer
195
On-Line Sampling
196
Grab Sampling
196
Ph of Sample Stream Is too High
197
Measure the Ph (Non-Deionized Water Only)
197
Oxidizer Flow Rate too High
198
Oxidizer Flow Rate too Low
198
DI Reservoir too Low
199
Gas Bubbles in Reagent Lines or Syringes
199
Negative or Zero TOC Measurements
200
Diagnostic Testing
203
Syringe Pump
204
Returning the Analyzer to Ionics Instruments
204
Preparing the Analyzer for Return Shipment
205
Repackaging the Analyzer for Shipment
208
11 RAM CARDS, CARD READER, and Ramreader SOFTWARE
210
Installing the Card Reader Hardware
210
Installing Ramreader Software
210
Removing the RAM Card
211
Placing the RAM Card in the Card Reader Device
212
Installing the RAM Card in the Analyzer
213
RAM Card Battery Maintenance
214
Appendix A - 810/810As Analyzer Operating Frequency
219
Selecting the Operating Frequency
219
Calibration
220
Appendix B - 820/820As Analyzer Operating Frequency
222
Checking the Operating Frequency
222
CE Mark Compliance
223
Printer Cable
223
Appendix C - Turbo Toc Analyzers
225
Introduction
225
Setting Turbo Sampling Model
226
Setting Reagent Flow Rates
227
Setting Alarms
229
Calibration in Turbo Sampling Mode
229
Turbo Mode TC Zero Offset
230
Turbo Mode TC Channel Calibration
231
Turbo Mode IC Channel Calibration
232
Alarm Settings
233
Accuracy Specifications
233
Appendix D - Binary Input Module - Flow Switch
234
Mechanical Installation
235
Firmware Installation
237
Replacing the EEPROM Chip (IC Chip
237
Replacing the IC Chip from an Zero Insertion Force-Type Socket
237
Replacing the IC Chip from a Low Profile-Type Socket
239
Software Configuration
241
Appendix E - Calibration Standard Preparation
245
Preparing the TC Calibration Standard
245
Part 1 - Measure TC of Water Used for Preparing Standards
245
Part 2 - Prepare a Stock TC Standard
248
Part 3 - Prepare a Dilute TC Standard
249
Preparation of the IC Calibration Standard
249
Part 1 - Prepare a Stock IC Standard
249
Part 2 - Prepare a Dilute IC Standard
251
Appendix F - Consumables and Accessories
253
Advertisement
Advertisement
Related Products
Sievers TOC 800
Sievers TOC 820
Sievers Categories
Measuring Instruments
More Sievers Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL