Sign In
Upload
Manuals
Brands
Sierra Monitor Corporation Manuals
Security Sensors
3600I
User Manuals: Sierra Monitor Corporation 3600I Detector
Manuals and User Guides for Sierra Monitor Corporation 3600I Detector. We have
1
Sierra Monitor Corporation 3600I Detector manual available for free PDF download: Instruction Manual
Sierra Monitor Corporation 3600I Instruction Manual (65 pages)
TRIPLE IR (IR3) FLAME DETECTOR
Brand:
Sierra Monitor Corporation
| Category:
Security Sensors
| Size: 1 MB
Table of Contents
Table of Contents
4
1 Introduction
9
Overview
9
Model and Types
10
Table 1: Wiring Options
11
Features and Benefits
12
Principles of Operation
12
Hydrocarbon Fire Detection
12
Heated Optics
13
Hart Protocol
13
Rs-485 Modbus
13
Product Certification
14
Performance Considerations
14
Detection Sensitivity
14
Table 2: Sensitivity Range Levels
15
Cone of Vision
16
Figure 1: Horizontal Field of View
16
Table 3: Fuel Sensitivity Ranges
16
Figure 2: Vertical Field of View
17
False Alarms Prevention
18
Table 4: Immunity to False Alarm Sources
18
Visual Indicators
19
Figure 3: Indication LED: Indication LED
19
Table 5: Welding Immunity Distance
19
Table 6: LED Indications
19
Output Signals
20
Table 7: Available Output Types
20
Detector Status
21
Table 8: Detector Status
21
Table 9: Output Signals Versus Detector State
21
Auxiliary Relay as End-Of-Line Resistor
22
Internal Detector Tests
22
Continuous Feature Test
22
Built-In-Test (Bit)
23
Table 10: Results of a Successful BIT
24
Table 11: Results of an Unsuccessful BIT
24
Table 12: Results of a Successful Manual BIT
25
Table 13: Results of an Unsuccessful Manual BIT
25
2 Installing the Detector
26
General Guidelines
26
Unpacking the Product
27
Checking the Product Type
27
Required Tools
27
Table 14: Tools
27
Certification Instructions
28
Installation Cables
29
Conduit Installation
29
Installing the Tilt Mount (Part No. 3600I)
30
Tilt Mount Specifications
30
Figure 4: Detector with Tilt Mount
30
Table 15: USA Version
30
Table 16: European Version
30
Installing the Tilt Mount
30
Tilt Mount Assembly
31
Figure 5: Tilt Mount Assembly
31
Figure 6: Tilt Mount Assembly (Dimensions in MM and Inches)
31
Connecting the Detector
32
Verifying the Detector Wiring
33
Figure 7: Detector with Cover Removed
33
Table 17: Model 3600I Wiring Options
34
Configuring Your Detector
35
Sensitivity
36
Alarm Delay
36
Address Set-Up
36
Table 18: Sensitivity Settings
36
Function Set-Up
37
Heated Optics
37
Table 19: Functions
37
3 Operating the Detector
38
Powering up
38
Safety Precautions
39
Default Functions Settings
39
Table 20: Default Function Values
39
Testing Procedures
40
Automatic Bit Test
40
Manual Bit Test
40
Testing with Fire Simulator Model 20/20-310
40
Table 21: Results of Successful Fire Simulator Test
41
4 Maintenance and Troubleshooting
42
Maintenance
42
General Procedures
42
Periodic Procedures
43
Keeping Maintenance Records
43
Troubleshooting
44
Table 22: Troubleshooting Table
44
Appendices
45
Specifications
46
Technical Specifications
46
A.1 Technical Specifications
46
Electrical Specifications
47
Outputs
47
A.2 Electrical Specifications
47
A.3 Outputs
47
Table 23: Electrical Specifications
47
Table 24: Contact Ratings
48
Table 25: 20 Ma Current Output
48
Mechanical Specifications
49
Dimensions
49
Weight
49
A.4 Mechanical Specifications
49
A.5 Dimensions
49
A.6 Weight
49
Environmental Specifications
50
A.7 Environmental Specifications
50
Table 26: Electromagnetic Compatibility (EMC)
50
Bwiring Instructions
51
General Instructions for Electrical Wiring
51
Table 27: Maximum DC Resistance at 68°F (20ºC) for Copper Wire
51
Table 28: Wiring Length in Feet (Meter)
51
Typical Wiring Configurations
52
Figure 8: Wiring Terminals
52
Figure 9: Typical Wiring for 4 Wire Controllers (Using Option 1 or 2 Wiring)
53
Table 29: Wiring Connections
53
Figure 10: 0-20Ma Wiring Option 1 (Sink 4-Wire) - Default
54
Figure 11: 0-2Ma Wiring Option 1 (Converted to Source 3-Wire)
54
Figure 12: 0-20Ma Wiring Option 1 (Unisolated Sink 3-Wire)
55
Figure 13: 0-20Ma Wiring Option 2 and 3 (Source 3-Wire)
55
Crs-485 Communication Network
56
Rs-485 Overview
56
C.1 Rs-485 Overview
56
Figure 14: RS-485 Networking
56
Daccessories
57
Long Range Ir3 Fire Simulator
57
Unpacking
57
D.1 Long Range Ir3 Fire Simulator
57
D.1.1 Unpacking
57
Figure 15: IR3 Long Range Fire Simulator 20/20-310
57
Operating Instructions
58
D.1.2 Operating Instructions
58
Figure 16: 3600I IR3 Detector Target Point
58
Range
59
Charging the Battery
59
D.1.3 Range
59
D.1.4 Charging the Battery
59
Table 30: Sensitivity Ranges
59
Technical Specifications
60
D.1.5 Technical Specifications
60
Tilt Mount - P/N 3600-001
60
Figure 17: Tilt Mount
60
Weather Protection - P/N 777163
61
Figure 18: Weather Protection
61
Laser Detection Coverage Pointer - P/N 777166
62
Air Shield - P/N 777161
62
Figure 19: Laser Detection Coverage Pointer
62
Figure 20: Air Shield
62
Esil-2 Features
63
3600I Flame Detector
63
Safety Relevant Parameters
63
Guidelines for Configuring, Installing, Operating and Service
63
Limited Warranty
65
Advertisement
Advertisement
Related Products
Sierra Monitor Corporation 3100-xx
Sierra Monitor Corporation 3100-01
Sierra Monitor Corporation 3100-02
Sierra Monitor Corporation 3100-03
Sierra Monitor Corporation 3100-04
Sierra Monitor Corporation 3100-05
Sierra Monitor Corporation 3100-06
Sierra Monitor Corporation Categories
Carbon Monoxide Alarm
Accessories
Measuring Instruments
Security Sensors
Controller
More Sierra Monitor Corporation Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL