Sign In
Upload
Manuals
Brands
Siemens Manuals
Measuring Instruments
SITRANS F FUS1020N
Siemens SITRANS F FUS1020N Manuals
Manuals and User Guides for Siemens SITRANS F FUS1020N. We have
1
Siemens SITRANS F FUS1020N manual available for free PDF download: Operating Instructions Manual
Siemens SITRANS F FUS1020N Operating Instructions Manual (271 pages)
Ultrasonic
Brand:
Siemens
| Category:
Measuring Instruments
| Size: 10 MB
Table of Contents
Important Notice
3
Manual Addendum
5
Table of Contents
13
Introduction to the FUS1020 NEMA-4 Flowmeter
21
System Hardware Description
21
Introduction to the FUS1020 Operating System
21
Installation Menu Overview
22
Overview of Real-Time Data Collection
22
Standard Features
22
Integral Datalogger
23
Analog Outputs
23
Performance Specifications (Example for Typical 6-Inch Pipe)
23
Mechanical, Electrical, Environment and Safety Specifications
24
Dual Channel Flow
25
Dual Path Flow
25
Channel 1+2 Flow
25
Clamp-On Transit-Time Theory of Operation
26
Wide Beam Tramsmission
27
Flow Calibration Factor
28
Getting Started
29
Important Safety Considerations
29
Power Connections
29
Input Power Connector (P1) and Fuse (F1) Locations
29
Power Supply Wiring
30
The Menu Lockout Switch
31
Flowmeter Installation Summary
31
Flowmeter Installation Flowchart
32
Choosing a Programming Interface
34
Overview of the 5-Key Touch Keypad
34
Overview of the RS-232 Interface
34
Installation Menu Operation with the Keypad
35
Accessing and Leaving the Installation Menu
35
Enter Key
36
System 1020 Installation Menu Structure
36
Installation Menu Structure
36
The Meter Facilities Menu
38
How to Use the Keypad to Enter Data
39
How to Select Items from an Option List
39
A Note on Multiple Select Option Lists
40
How to Enter Numeric Data
40
How to Enter Alphanumeric Strings
42
How to Use the RS-232 Interface
43
The RS-232 Interface Cable
43
Establishing Communications Using Hyperterminal
44
Accessing the Installation Menu
45
Data Display Mode
46
Data Entry Using the RS-232 Interface
46
Accessing and Leaving the Installation Menu
46
Navigating through the Installation Menu
47
Introduction to the 1020 Menu Screens
48
Typical 1020 Installation Menu Screen
48
Explanations of Installation Menu Callouts
48
Data Entry Procedures Using the RS-232 Interface
49
Entering Alphanumeric Strings
49
Selecting Items from an Option List
50
Multiple Select Option Lists
52
Entering Numeric Data
52
How to Set up a Channel for Transit-Time Operation
53
How to Access the Channel Setup Menu and Create a Site
53
How to Enter Pipe Data
54
How to Select a Liquid Type
55
How to Manually Select Transducers and a Mounting Mode
56
Installing the Transducers
58
Setting the Zero Flow Level
60
Performing the Actual Zero Routine
60
Using the Reversamatic Routine
62
Hardware Installation Guide
65
Input/Output Wiring
66
1020N Input/Output Wiring (TB1 and TB2)
66
1020DN Input/Output Wiring (TB1 and TB2)
67
Preparing to Mount the Transducers
68
How to Indentify 1021 Transducers and Mounting Hardware
68
Selecting a Location for Clamp-On Transducers
68
Clamp-On Transducer Mounting Modes
69
Reflect Mount
69
Direct Mount
70
Preparing the Pipe
70
Preparing the Pipe Surface
70
Sonic Coupling Compound Recommendations
71
Recommended Sonic Coupling Compounds
71
Reflect Mode Transducer Installation
72
Dual Mounting Track Assembly/Transducer Installation
72
Dual Mounting Track Assembly/Transducer Installation for Dual Channel Integrated 1020 Flowmeter
76
Single Mounting Track Assembly/Transducer Installation
77
Figure
79
Single Mounting Track Assembly/Transducer Installation for Single Channel Integrated 1020 Flowmeter
80
Integrated Flowmeter Secured to Mounting Track Cover Assembly
82
Connect Transducer Cables Ensuring Upstream/Downstream Orientation Is Correct (Figure 3)
82
Confirm Installation Is Functional by Completing Flowmeter Menu
82
Figure 6
82
Direct Mode Transducer Installation
83
Dual Mounting Track Assembly/Transducer Installation
83
Connect Transducer Cables
83
Finding the Halfway Distance
86
Side View
88
Dual Mounting Track Assembly/Transducer Installation for Dual Channel Integrated 1020 Flowmeter
90
How to Identify 1011 Transducers and Mounting Hardware
91
Reflect Mode - Mounting Frames and Spacer Bar
91
Reflect Mode with Spacer Bar Only
93
Direct Mode - Mounting Frames, Spacer Bar and Mounting Guides
94
Using 1012T Mounting Tracks
99
Installing a 1012T Mounting Track in Reflect Mode
99
Front View
100
Installing a 1012T Mounting Track in Direct Mode
101
Top View
101
Operating System 1020 with Flow Tubes
105
General Installation Guidelines
105
Liquid Applicability and Compatibility
105
Selecting the Right Flow Tube
106
Flow Tube Mounting Location
106
Flow Data Scatter and Damping
107
Considerations for Critical Applications
107
How to Set up System 1020 for Flow Tube Operation
108
Overview
108
Setup Procedure
108
Specifications - CPVC Flow Tube
113
Specifications - KYNAR PVDF Flow Tube
113
Specifications - TEFLON PFA Flow Tube
114
Specifications - 316 Stainless Steel Flow Tube
114
Additional Installation Notes
115
System 1020 Application Notes
117
To Obtain Technical Assistance
117
Considerations for Critical Applications
117
Pipe Dimensions
118
Picking the Appropriate Transducer
118
Flow Velocity Range
118
Overview of System Performance
118
Accuracy
119
Repeatability
119
Data Stability
119
Data Scatter
119
Data Drift
119
Flow Conditions
120
Low Flow Rates
120
Flow Data Scatter and Damping
120
System 1020 Damping and Slewing Controls
120
Time Average
120
Smartslew
120
Notes on Liquid Conditions
121
Erroneous Liquid Parameter Specification
121
Liquid Compatibility
121
Aeration
121
Slurries
122
Two-Phase Liquids
122
Viscous Liquids
122
Temperature and Pressure Ratings
122
Overview of System 1020 Memory Resources
122
Reference Tables
123
Vps Values (in Inches/Second) for some Common Metals
124
Sonic Velocity of Pure Water Relative to Temperature
125
System 1020 Reynolds Compensation Factor
126
Terminology Chart
127
The Meter Type Menu
129
The Meter Facilities Menu
129
The Clamp-On Menu
130
The 1020 Installation Menu
133
General Installation Menu Notes
133
The Channel Setup Menu
134
Channel Setup Menu Structure
134
How to Recall a Site Setup
134
How to Enable and Disable a Measurement Channel
135
How to Create/Name a Site Setup
136
How to Enable/Disable Site Security
136
How to Delete a Site Setup
137
How to Save/Rename a Site Setup
137
The Pipe Data Menu
138
Pipe Table Menu Structure
139
How to Select a Pipe Class
140
How to Select a Pipe Size
140
How to Enter the Pipe OD (In. or MM)
141
How to Select a Pipe Material
141
How to Enter the Wall Thickness
141
Liner Material
142
Liner Thickness
142
The Application Data Menu
142
Application Data Menu Structure
143
How to Select a Liquid Class
144
How to Edit the Estimated Vs (Liquid Sonic Velocity)
144
How to Edit the Viscosity (Cs) Setting
145
How to Edit the Density (SG) Setting
145
Pipe Temperature Range
146
Pipe Configuration
146
Pipe Configuration Menu Structure
147
Pipe Configuration Option List Definitions
147
The Pick/Install XDCR Menu
148
Pick/Install Xdcr Menu Structure
149
How to Select a Transducer Model
149
How to Select a Transducer Size
150
How to Select a XDCR Mount Mode
150
Reviewing the Spacing Method
151
How to Use the Spacing Offset
151
The Number Index Menu Cell
151
The Ltn Menu Cell
152
How to Use [Install Complete?]
152
Force Transmit Procedure
153
The Empty Pipe Set Menu
156
How to Use the Actual MTY Command
156
How to Use the Mtymatic Command
157
How to Use the Set Empty Command
157
Zero Flow Adjust Menu
158
Autozero
158
Actual Zero
158
Reversamatic
158
Zeromatic (Description)
158
Using Actual Zero
159
Using Reversamatic
159
Zeromatic (Optional Function)
160
The Operation Adjust Menu
162
Operation Adjust Menu Structure
162
Damping Control
163
Deadband Control
163
Memory/Fault Set
164
Memory Delay (Sec)
164
The Flow/Total Units Menu
164
Totalizer Controls
165
The Flow/Total Units Menu Structure
166
Flow Volume Units
167
Flow Time Units
167
Flow Display Range
168
Flow Display Scale
168
Total Volume Units
168
Totalizer Scale
169
Total Resolution
169
Totalizer Mode
170
Batch/Sample Total
170
Reset Totalizer
170
The Data Span/Set/Cal Menu
170
The Data Span/Set/Cal Menu Structure
171
Span Data
171
Pgen
172
Max Flow
173
Min Flow
173
Max Vs M/S
173
Min Vs M/S
173
Set Alarm Levels
174
Hi Flow
174
Low Flow
174
Interface Vs (M/S) Meters-Per-Second
174
Aeration
175
Makeup Latch
175
Calibrate Flowrate
176
Kc Calibration
176
Multipoint Calibration
176
The Datalogger Setup Menu
178
The Datalogger Setup Menu Structure
179
Datalogger Mode
180
Datalogger Data
180
Alarm Letter Codes and Descriptions
180
Log Time Interval
181
Datalogger Events
181
The I/O Data Control Menu
182
The I/O Data Control Menu Structure
183
Analog Output Setup
183
System 1020 Analog Outputs
183
Analog out Setup Data Categories
183
Assigning Io Output Functions
183
Relay Setup
184
Assigning Relay 1 Functions
184
Relay 1 Option List
184
The Meter Facilities Menu
185
Preferred Units
186
The Table Setups Menu
186
Pipe Table
186
Pipe Table Menu Structure
187
Create/Edit Pipe
188
Delete Pipe
189
Transducer Type Menu
189
Transducer Type Menu Structure
190
The Datalogger Control Menu
190
Datalogger Control Menu Structure
191
Output Datalogger
191
Circular Memory
191
Est Log Time Left
192
Clear Datalogger
192
The Memory Control Menu
192
The Analog Output Trim Menu
193
Analog Output Trim Menu Structure
193
Current Output Trim (Io1 & Io2)
193
PGEN Output Trim (Single Channel Models Only)
193
The Clock Set Menu
194
Clock Set Menu Structure
194
Date
194
Time
194
Setup
195
Setup Menu Structure
195
Baud Rate
195
Parity
196
Data Bits
196
Line Feed
196
Network ID
197
RTS Key Time
197
System Info
198
System Info Menu Structure
198
Data Display Screen
198
Activating the Display
198
Selecting Display Data Items
199
The Diagnostics Data Menu
201
Diagnostic Data Menu Structure
201
Main Diagnostics Screen
202
Diagnostic Main Menu Description
202
Flow Data Menu
202
Flow Data Menu Items
203
Vs M/S
204
Hiflow and Loflow
204
Ancal
204
The Application Info Menu
205
Application Info Menu Items
205
The Liquid Data Menu
205
Liquid Data Menu Items
206
The Site Setup Data Menu
206
Site Setup Menu Items
206
Introduction to [HF] Menu Item
207
Using the [HF] Menu Item
207
Manual" Adjustment Procedure
208
Automatic" Adjustment Procedure
209
The Test Facilities Menu
210
Test Facilities Commands
210
Makeup
210
Troubleshooting Tips
211
Flow Computer Messages
211
Using the 1020 Reset Sequence
213
System Reset Using the Keypad
213
System Reset Using the RS-232 Interface
214
Appendix Aengineering Drawings
217
Appendix B Site Setup Considerations for 1010/1020N Blind Systems
245
Index
255
Ductile Iron Pipe
267
Advertisement
Advertisement
Related Products
Siemens FUS1010
Siemens FUS1010 IP65 NEMA 4X
Siemens FUS1010 IP66 NEMA 7
Siemens SITRANS FUS1020
Siemens SITRANS F FUS1020 IP65 NEMA 4
Siemens SITRANS F FUS1020DN
Siemens SITRANS FUS380
Siemens SITRANS FUS080
Siemens SITRANS FUT1010 IP65 NEMA 4X
Siemens SITRANS FUT1010
Siemens Categories
Industrial Equipment
Controller
Oven
Control Unit
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL