Sign In
Upload
Manuals
Brands
Siemens-Allis Manuals
Circuit breakers
LA-1600A
Siemens-Allis LA-1600A Circuit Breaker Manuals
Manuals and User Guides for Siemens-Allis LA-1600A Circuit Breaker. We have
4
Siemens-Allis LA-1600A Circuit Breaker manuals available for free PDF download: Instructions Manual
Siemens-Allis LA-1600A Instructions Manual (34 pages)
Switchgear
Brand:
Siemens-Allis
| Category:
Industrial Equipment
| Size: 1 MB
Table of Contents
Table of Contents
2
Warranty
3
Typical Shipping Method Used with "LA" Breakers
3
Typical LA·600A and la
3
Fused Unfused Breakers with Static Trip II and Limitrip Overcurrent Trip Devices
4
Figure 11. LAF-600A, LAF-800A and LAF·1600A Open Fuse Trip Device, Trigger Fuse Assembly
4
Receiving and Inspection for Damage
5
Installation Sequence Cautions to be Observed in Installation and Operation
6
Operation
6
Description
6
Table 1. Circuit Breaker Ratings at 60 Hertz
7
(A) Manually Operated Circuit Breakers
8
(B) Electrically Operated Circuit Breakers
8
Table 4. Operating Procedure - Electrically Operated Breakers
8
LA-600A, LA·800A and LA-1600A Operator
9
Figure 2. Typical Wiring Diagram - Electrically Operated Breakers
10
(C) Combination E. O. Circuit Breakers
11
Drawout Interlock
11
Racking Mechanism
11
Figure Detail of Typical Racking Mechanism and Drawout Interlock
11
Spring Discharge Interlock
12
Figure 3A. Typical Racking Mechanism and Drawout Interlock
12
Lifting Bar
13
Handling Instructions
13
Maintenance and Adjustments
14
Maintenance
14
Maintenance Closing
16
Operated
17
Maintenance Closing
17
Table 5. Maintenance Closing
17
Adjustments
18
Trip-Latch Engagement
18
Main Contact Make
19
Arcing Contact Make
19
Figure 8. Contact Assembly
19
Contact Replacement
20
Main Contact Finger
20
Hinge Contact Fingers
20
Movable Arching and Main Contact
20
Stationary Arcing Contact
20
Tripping Actuator
20
Motor Cutoff Switch
21
Fuse Functions
22
Current Limiting Fuses
22
Fuse Attachment Group LAF-600A, LAF·800A Breakers
23
Open Fuse Trip Device
25
Accessories
26
Current Sensors
26
Tripping Transformers- Static Trip II
26
Table Operating Procedure - Manually Table 7. Umitrip Rating Table- Amperes
26
Secondary Disconnect Assembly Option
27
Optional Devices
27
Figure 12. LA·600A, LA·800A and LA-1600A Secondary Disconnect Group
27
Auxiliary Switch Option
28
Auxiliary Switch Option Shunt Trip Option
29
Undervoltage Trip Device Option
29
Shunt Trip Option
29
Static Trip Option
29
Figure 14. Undervoltage Trip with or Without Time Delay
29
Figure 15. LA·600A, LA·800A and LA-1600A Shunt Trip Group
29
Lubrication
30
Lubrication Instructions
30
Bell Alarm Switch Option
30
Alarm Switch Group, Bell Alarm
30
Figure 18. Lubrication Points on Breaker
32
Instruction Book References
34
Advertisement
Siemens-Allis LA-1600A Instructions Manual (38 pages)
AIR CIRCUIT BREAKERS WITH MANUAL OR ELECRICAL OPERATORS
Brand:
Siemens-Allis
| Category:
Circuit breakers
| Size: 1 MB
Table of Contents
Table of Contents
3
Spring Discharge Interlock
5
Maintenance Closing
5
La-600A
5
Laf-600A
5
Manually
5
Fusef Unctions
5
Bell Alarm Switch Option
5
Breakers
6
Adjustments
6
Installation and Inspection
6
Introduction
6
Receiving and Inspection for Damage
6
Installation
6
Storage
7
Operation
8
Description
8
Operat Ed
9
Electrically -Operated Breaker
9
Racking Mechanism, Drawout Interlock and Lifting Bar
10
Maintenance and Adjustments
13
Maintenance
13
Lubrication
14
Trip Latch Engagement
15
Main Contact Make
15
Adjustments
15
Arcing Contact Make
16
Contact Replacement
16
Main Contact Fingers
16
Stationary Arcing Contact
16
Hinge Contact Fingers
16
Moving Arcing and Main Contact
17
Tripping Actuator
17
Current Limiting Fuses
19
Fuse Functions
19
Current Limit Fuse
19
Trigger Fuse
19
Auxiliary Switch Option
20
Shunt Trip Option
20
Optional Devices
20
Undervoltage Trip Device Option
20
Tripping Transformers
20
Secondary Disconnect Assem. Option
20
Figure 1. LA-600A
21
Amperes
21
Static Trip Option
22
La-600A
24
Operated Breakers
25
Electrically
27
Laf-600A
31
Trigger Fuse Assembly
31
Group
32
La·600A
34
Siemens-Allis LA-1600A Instructions Manual (37 pages)
FUSED AND UNFUSED AIR CIRCUIT BREAKERS
Brand:
Siemens-Allis
| Category:
Circuit breakers
| Size: 1 MB
Table of Contents
Table of Contents
2
Warranty
3
Installation and Inspection
4
Receiving and Inspection for Damage
4
Installation
4
Storage
5
Operation
6
Description
6
Manually·operated Breaker
6
Electrically-Operated Breaker
7
Table 1 Operating Procedure - Manually
7
Racking Mechanism, Drawout Interlock and Lifting Bar
8
Table 2 Operating Procedure - Electrically
8
Spring Discharge Interlock
9
Maintenance and Adjustments
11
Lubrication
12
Maintenance Closing
12
Adjustments
13
Trip-Latch Engagement
13
Main Contact Make
13
Maintenance Closing
13
Arcing Contact Make
14
Contact Replacement
14
Main Contact Fingers
14
Stationary Arcing Contact
14
Hinge Contact Fingers
14
Moving Arcing and Main Contact
15
Tripping Actuator
15
Fuse Functions
17
Current Limit Fuse
17
Tripping Transformers
18
Optional Devices
18
Secondary Disconnect Assem. Option
18
Auxiliary Switch Option
18
Shunt Trip Option
18
Undervoltage Trip Device Option
18
Table 4 Trip Rating Table - Amperes
19
Bell Alarm Switch Option
20
Static Trip Option
20
Front View
21
Side View
24
Rear View
28
Plan View
34
Bottom View
35
Advertisement
Siemens-Allis LA-1600A Instructions Manual (33 pages)
LOW -VOLTAGE AC POWER CIRCUIT BREAKERS
Brand:
Siemens-Allis
| Category:
Circuit breakers
| Size: 1 MB
Table of Contents
Table of Contents
2
Circuit Breakers
5
Electrically Operated Circuit Breakers
8
Eo Hertz
8
Drawout Interlock
11
Racking Mechanism
11
Typical Rac:t;Idl Mecbanlun and Drlwout Intertock
12
Handling Instructions
13
Lifting Bar
13
Maintenance
14
Typical LA·1600A Breaker Ouuine
14
Maintenance and Adjustments
14
Lubrication
15
Typical LA·600A and LA-800A Breaker Outline
15
Maintenance Closing
16
Maldtenuce Ck"II.q
16
Taintenanee Cloain
17
Adjustments
18
Trip· Latch Engagement
18
Typical Operator Assembly
18
Main Contact Make
19
Arelnl Contact Make
19
Contact
19
Fuse Attachment Group LAF·600A, LAF·800A Breaken
23
Fuse Attachment Group LAF·1600A Breaker
24
Fuse Aaaembly
25
Ope
25
Stau. Tdp II Iiitiai Table - Ampe
26
Optional Devices
27
Secondary Disconnect Assembly Option
27
LAF·600A, LAF-800Aand LAF·I600A Open Fuse Trip Device, Trtger LA-600A, LA·800A and LA·I600A Sec:onduy Disconned Group
28
Auxiliary Switch Option
28
LA-600A. LA·800A and La·l600A Auxiliary Swltcb Group
28
LA-600A. LA-800A Add La·l600A Shunt Trip Group
29
Time Delay
29
Underyoltq:e Trip Device Option
29
Alum
30
Lubrication Instructions
30
Stllic Tr1P Option Bell Alarm Switch Option
30
Alarm Swlteb Group, Bell Lubrication Chart
31
Advertisement
Related Products
Siemens-Allis LA-3200A
Siemens-Allis LA-4000A
Siemens-Allis LA-40008
Siemens-Allis LA3000A
Siemens-Allis LA-600A
Siemens-Allis LAF-60A
Siemens-Allis LAF-1600A
Siemens-Allis LA-800A
Siemens-Allis LAF-600A
Siemens-Allis LAF-800A
Siemens-Allis Categories
Circuit breakers
Industrial Equipment
Switch
Controller
More Siemens-Allis Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL