Table of Contents
3
1 System Planning
7
Introduction
7
Installation Overview
7
Security Factors
8
Fence Structures
8
Standard Flexible Fence Types
9
Chain-Link Fence
9
Welded-Mesh Fences
9
Expanded Metal Fences
9
Rigid Fence Types
10
Palisade Fences
10
Climb-Over Deterrent Hardware
10
Barbed Wire
10
Razor Ribbon
10
Gates
11
Buildings, Walls and Other Structures
12
Environment
12
Site Survey
13
Perimeter Layout Guidelines
14
Flexzone Sensor Cable
14
Cable Layout Guidelines
15
Cable Length Calculator (Flexible Fences)
15
Rigid Fences
16
Fence Height Recommendations
16
Non-Detecting Cable
16
Fence Corners and Heavier Gauge Posts (Flexible Fences)
17
Zone Demarcation Loops (Flexible Fences)
17
Service Loops (Flexible Fences)
17
Drip Loops (Flexible Fences)
17
Termination Loops (Flexible Fences)
17
Splice Loops (Flexible Fences)
17
Gate Bypass
18
Armored Cable
18
Double Pass Coverage
18
Processor Location Guidelines
19
Power Source and Wiring
20
Power over the Sensor Cables
20
Auxiliary Device Output Power
20
Power over Ethernet
21
Grounding Considerations
21
Alarm Communication Options
22
Fail-Safe Relay Operation
22
Relay Output Card
22
Dry Contact Input Card
22
Data over the Sensor Cables
22
Processor Synchronization
23
Alarm Monitoring
23
NM Mode
23
Cable Connectors
23
High Security Installations
24
High-Security Installation Rules
24
2 Installation
25
Installing the Sensor Cable
25
Cable Handling Rules
25
Flexzone Sensor Cable Conditioning
26
Cable Conditioning Procedure (Part 1 - Cable Preparation)
26
Cable Conditioning Procedure (Part 2 - Cable Flossing)
27
Installing Cable on Chain-Link Fences
29
Installing Cable Ties
29
Bend Radius
30
At Fence Posts
30
At Corners or Heavy Gauge Posts
30
At Software Defined Zone Boundaries
31
Service Loops
31
Drip Loops
32
Termination Loops
32
Splice Loops
33
Installing Cable on Welded-Mesh Fence
34
Double Pass Cable Installation
35
Installing Cable on Rigid Fences
36
Sensor Cable Connections
36
Cable Preparation (All Connections)
37
Processor Connections
38
Sensor Cable Splices
39
Sensor Cable Terminations
40
Using the Wireless Gate Sensor to Protect Gates
42
Installing Sensor Cable on Gates
42
Gate Bypass Cable
43
Bypass Cable Installation Instructions
43
Installing Sensor Cable on Swinging Gates
43
Gate Disconnect Assembly
44
Installation Instructions
44
Installing Armored Flexzone Sensor Cable
45
Installing Armored Flexzone Sensor Cable
46
Installing Cable on Barbed Wire
46
On Razor Ribbon
46
Splicing Armored Sensor Cable
46
Armored Cable Terminations
48
Connecting Armored Sensor Cable to the Processor
50
Installing the Flexzone Processor
51
Cable Entry Ports
52
Free-Standing or Fence Post Mounting the Enclosure
53
Surface Mounting
54
Grounding
55
Relay Outputs
55
Relay Contact Ratings
55
Auxiliary Inputs /Self-Test Inputs
55
Processor Wiring Connections
56
Silver Network Wiring Connections
58
Silver Network Specifications
58
Silver Network Data Path Connections
60
Power Connections
63
Power over Sensor Cables
63
Local Power Supply
63
Power over Ethernet
64
Auxiliary Device Power Output
64
Backup Power
64
3 Calibration & Setup
67
The Universal Configuration Module
67
Flexzone Definitions
68
Understanding Flexzone Alarm Detection
68
Intruder Detection
69
Intrusion Detection
69
Initial Processor Setup
70
Connecting the UCM Via USB
70
Setting the Processor Address
70
Network Configuration
70
Sensor Cable Supervision
71
Adjacent Processor (M) Setting
71
Power over Sensor Cables
72
Processor Synchronization
73
Audio "Listen-In" Function
73
Using the Audio Listen-In Function Via the UCM
73
Using the Audio Listen-In Function Via the Flexzone Audio Tool
74
Processor Calibration
75
The Sensitivity Profile
75
Recording the Sensitivity Profile
75
Detection Parameter Setup
77
Defining a Zone
77
Setting the Cable Threshold
77
Defining the Cable Segments and Alarm Zones
78
Locating the Cable Segment Boundaries
78
Defining the Cable Segment Boundaries
78
Defining Sensor Cable as Non-Detecting (Setting the Start Point of Detecting Cable)
79
Defining the Detecting Cable Segments
79
Setting the Endpoint of Detecting Cable
80
Setting Individual Cable Segment Thresholds
81
Setting the Segment Threshold
81
Intrusion Simulations
81
Input/Output Configuration
82
Specify the Auxiliary I/O Control Mode and Option Card
82
Auxiliary (Aux) Inputs
82
Local Control Mode
83
Remote Control Mode
83
Input Configuration Procedure (Remote Control Mode)
84
Output Relays
84
Output Relay Setup (Local Control Mode)
84
Output Relay Setup (Remote Control Mode)
84
Linking Cable Segments to Relays (Local Control Mode)
85
System Test Procedure
85
4 Maintenance
87
Recommended Maintenance
87
Preventing Weather Related Nuisance Alarms
88
Using the SD Card Function
88
Testing the Fence Condition
88
Ground Faults
88
Adjusting the Target Filters
89
Replacing the Processor
90
Removing the Processor Assembly
90
Replacing the Processor Assembly
90
Updating the Firmware
91
Parts List
93
Specifications
97
NM Mode
99
UCM Configuration
100
Advertisement
Advertisement
Related Products
SENSTAR FlexPS
SENSTAR FlexZone WGS
SENSTAR FiberPatrol FP1400 Series
SENSTAR FiberPatrol FP1100X-01
SENSTAR FiberPatrol FP1100X-06
SENSTAR FiberPatrol FP1100X-09
SENSTAR FiberPatrol FP1100X-12
SENSTAR FiberPatrol FP1100X-16
SENSTAR FiberPatrol FP1100X-20
SENSTAR FiberPatrol FP1400-08
SENSTAR Categories
Accessories
Security System
Security Sensors
Control Systems
Protection Device
More SENSTAR Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL