Sign In
Upload
Manuals
Brands
Samson Manuals
Control Systems
TROVIS 6494
Samson TROVIS 6494 Manuals
Manuals and User Guides for Samson TROVIS 6494. We have
1
Samson TROVIS 6494 manual available for free PDF download: Mounting And Operating Instructions
Samson TROVIS 6494 Mounting And Operating Instructions (38 pages)
Automation System; Compact Controller;
Brand:
Samson
| Category:
Control Systems
| Size: 0.41 MB
Table of Contents
Table of Contents
2
Description
4
Version
4
Technical Data
6
Installation
7
Electrical Connections
8
Operation
10
Control Panel, Displays and Operating Elements
10
Operation of the Three Levels
12
Operating Level
12
Modify Setpoint W1
12
Display Sensor Line Breakage
13
Parameterization Level
14
Determine and Modify the Control Parameters
14
Open the Parameterization Level
14
Proportional-Action Coefficient P (Kp)
15
Integral-Action (Reset) Time I (Tn)
15
Derivative-Action (Rate) Time D (Tv)
15
Output Variable Limits y
15
Working Point YP
15
Limit Values 1A and 2A
15
Differential Gap 1H and 2H
15
Dead Band (Neutral Zone) Td
16
Hysteresis Th
16
Configuration Level
17
Determine and Modify Controller Functions
17
Open the Configuration Level
17
Select Input Signal in
18
Measuring Range Limits In_ _ and in
18
Decimal Point Ind
18
Select the Current or Voltage Ranges of Controlled Variable X with In0
18
Unit of Temperature Int
19
Digital Filter Inf
19
Select the Input Circuitry of the D (Derivative)-Action Component with DI
19
Select Setpoint SP
19
Setpoint Ramp Spr
20
Inhibit (HOLD) Modification of Setpoint SPH
20
Lock (HOLD) the MANUAL/AUTOMATIC Key YH
20
Select Controller Output y
20
Operating Direction Yr
20
Select the Current Range of Controller Output y with Y0
20
Safety Output (Restart) Value Yst
21
Limit Alarm Condition for Switching Output Y1
21
Switching Output Y1 as Break or Make Contact Y1C
21
Limit Alarm Condition for Switching Output Y2
21
Switching Output Y2 as Break and Make Contact Y2C
22
Adaption (Self-Tuning) Adp
22
Enter Code Numbers CPA and CCO
22
Code Number for Servicing
23
Switching Outputs Y1 and Y2
24
Three-Step Controller with Internal Feedback (y = 1)
25
Limit Contacts
26
General Definition
26
Assignment of the Limit Alarm Conditions for Switching Outputs Y1 and Y2
27
Monitor Output Signal y
27
Pulse-Modulated On-Off Controller Output at Switching Output Y1 And/Or Y2
28
On-Off Pulse-Modulated Controller Output with Limit Alarm
28
Two Pulse-Modulated On-Off Switching Outputs
28
Start-Up Procedure
29
EEPROM Version
29
Configure the Different Controller Outputs
29
Continuous-Action Controller ( y = 0 )
29
Three-Step Controller with Internal Feedback ( y = 1 )
30
Controlled Variable X as Recorder Input ( y = 2 )
30
Optimize the Control Parameters
31
Adaption (Self-Tuning)
33
Checklist
34
Advertisement
Advertisement
Related Products
Samson Trovis 6493
Samson Trovis 6400
Samson Trovis 6412
Samson Trovis 6442
Samson TROVIS 6495 Series
Samson TROVIS 6495-2
Samson TROVIS 6497
Samson 6-in-one
Samson 6116
Samson 6126 i/p
Samson Categories
Controller
Control Unit
Microphone
Valve Positioners
Speakers
More Samson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL