Sign In
Upload
Manuals
Brands
Rohde & Schwarz Manuals
Test Equipment
CMW 500
User Manuals: Rohde & Schwarz CMW 500 Radio Tester
Manuals and User Guides for Rohde & Schwarz CMW 500 Radio Tester. We have
1
Rohde & Schwarz CMW 500 Radio Tester manual available for free PDF download: Operating Manual
Rohde & Schwarz CMW 500 Operating Manual (450 pages)
Wideband Radio Communication Tester
Brand:
Rohde & Schwarz
| Category:
Test Equipment
| Size: 20 MB
Table of Contents
Table of Contents
5
Preparing for Use
21
Front Panel Tour
21
Utility Keys
22
Status Leds and Standby Key
22
Display
23
Softkeys and Hotkeys
23
Setup Keys
23
Data Entry Keys
24
Rotary Knob and Navigation Keys
25
Front Panel Connectors
26
RF Connectors
26
LAN Connector
28
SENSOR Connector
28
USB Connectors
28
AF Connectors
28
Rear Panel Tour
28
Instrument Setup
30
Unpacking the Instrument and Checking the Shipment
30
Putting the Instrument into Operation
30
Bench Top Operation
31
Mounting in a 19" Rack
32
EMI Protective Measures
33
Connecting the Instrument to the AC Supply
33
Power on and off
33
Replacing Fuses
34
Standby and Ready State
34
Connecting External Accessories
35
Storing and Packing
35
Maintenance
35
Connecting a Mouse
36
Connecting a Keyboard
36
Connecting a Printer
37
Connecting a Monitor
38
Connecting a LAN Cable
38
Starting the R&S CMW 500 and Shutting down
39
Remote Operation in a LAN
40
Assigning an IP Address
40
Firmware Update
42
Windows XP
42
Remote Desktop Connection
42
Basic Tasks
45
Accessing Dialogs
45
Getting Started
45
Using Keyboard Shortcuts
47
Data Entry
47
Using Front Panel Keys
48
Using an External Keyboard
49
Task Bar
50
GPRF Generator
51
Sample Session
51
Generating an RF Signal
51
Measuring an RF Signal
53
GPRF Power
53
System Overview
56
Generators
56
Generator Control
56
RF Path Settings (Generators)
57
Measurement Control
58
Measurements
58
Connection Control (Measurements)
59
Statistical Settings
60
Statistical Results
61
Statistics Type
62
Detectors
63
Peak Values
63
Averaging
64
Standard Deviation
64
Trigger Settings
65
TX Measurements
65
Power Results
66
Modulation Accuracy
66
Adjacent Channel Power (Spectrum)
69
Spectrum Emission Mask
69
Code Domain Power
70
Multi-Evaluation Measurements
71
Basic Instrument Functions
73
Startup Dialog
73
Utility Dialogs
74
Reset Dialog
74
Print Dialog
75
Save/Recall Dialog
76
Setup Dialog
77
Activating Options
78
Selftests
79
General Test Features
80
Board Tests
81
System Tests
82
Performing Selftests
82
Selftest Parameters
83
Reference Frequency
85
Reference Frequency Settings
85
Measurement Controller Dialog
86
Generator Controller Dialog
86
Remote Control
88
Remote Control Operation
88
Establishing and Testing a LAN Connection
90
Switchover to Remote Control
91
Return to Manual Operation
91
GPIB Bus Interface Messages
92
Interface Messages
92
Messages
92
Device Messages (Commands and Device Responses)
93
SCPI Command Structure and Syntax
93
Common Commands
94
Instrument-Control Commands
94
Structure of a Command Line
96
Responses to Queries
96
SCPI Parameters
97
R&S CMW Software and Command Structure
99
Use of SCPI Subsystems
99
General Command Structure
100
Firmware Applications
101
Measurement Contexts and Views
101
Control of the Instrument
102
Measurement Control
102
Measurement States and Measurement Control Commands
103
Initiate:<Application>:Measurement<I
104
Measurement Substates
105
Abort:<Application>:Measurement<I
105
Stop:<Application>:Measurement<I
105
Statistical Settings
106
Retrieving Measurement Results
108
Fetch
108
Read
109
Retrieving Single Values and Traces
110
Reliability Indicator
110
Common Reliability Indicator
110
Multi-Evaluation Measurements
111
Generator Control
112
RF Path Settings
114
Resource and Path Management
114
Basic RPM Principles
115
Queuing of Measurements
116
Causes for Task Conflicts
118
Monitoring Measurement and Generator States
119
Command Processing
119
Command Recognition
120
Input Unit
120
Data Base and Instrument Hardware
121
Status Reporting System
121
Output Unit
122
Status Reporting System
122
Overview of Status Registers
123
Structure of an SCPI Status Register
123
Description of the Five Status Register Parts
124
STB and SRE
125
Contents of the Status Registers
125
IST Flag and PPE
126
ESR and ESE
127
Status:operation
128
Status:questionable
128
Application of the Status Reporting System
128
Service Request
128
Serial Poll
129
Parallel Poll
129
Query of an Instrument Status
130
Error Queue
131
Reset Values of the Status Reporting System
131
Command Reference
133
Special Terms and Notation
133
Common Commands
135
Instrument-Control Commands
137
Mmemory Commands
137
Ref Frequency Commands
140
Status Commands
141
System Commands
145
LAN Services
145
Miscellaneous Instrument Settings
148
Alphabetical List of Commands (System)
151
GPRF Applications
153
GPRF Measurements and Generators
153
General Purpose RF Generator
153
GPRF Generator (Constant Frequency)
153
Arbitrary RF Generator (Option R&S CMW-B110 A)
154
List Mode
155
Power Measurement
155
Test Setup
155
Single Power Steps and List Mode
156
Trigger Modes
157
Measurement Settings
158
Power: Results
158
External Power Sensor Measurement
160
Sensor Connection and Test Setup
160
Measurement Settings
161
Zeroing
162
External Power Sensor: Results
163
GPRF GUI Reference
163
General Purpose RF Generator
164
Generator Control and Signal Routing
164
GPRF Generator (Constant Frequency)
165
Baseband Configuration
166
ARB Generator (Option R&S CMW-B110 A)
167
List Mode
168
Power: Parameters and Settings
170
Measurement Control
171
Power Configuration: Signal Routing and Analyzer Settings
171
Power Configuration: Measurement Control
172
Power Configuration: List Configuration
175
Power Configuration: Trigger Settings
176
Power Configuration: Display Parameters
177
Measurement Results
178
External Power Sensor: Parameters and Settings
180
Measurement Control
180
External Power Sensor Configuration
181
Measurement Results
183
Key Features
184
Programming the GPRF Generator
184
GPRF Programming
184
Generating a CW Signal
185
Generating a Dual-Tone Signal
185
Using the Generator List Mode
186
Programming the Power Measurement
187
Key Features
187
Specifying General Measurement Settings
188
Specifying Measurement-Specific Settings
188
Configuring the List Mode
189
Performing a Single Shot Measurement
189
Single Shot and Continuous Power Measurements
190
Programming the External Power Sensor Measurement
190
Key Features
191
Performing a Single Shot Measurement
191
Zeroing the External Sensor
192
Continuous Sensor Measurement
192
GPRF Command Reference
192
General Measurement Settings
192
Signal Routing
193
Command Groups (General Measurement Settings)
193
Analyzer Settings
194
GPRF Generator Commands
195
Command Groups (RF Generator)
195
Generator Control and States
196
Signal Routing
196
Constant-Frequency Settings
197
Baseband Settings
198
Source:gprf:gen<I>:Dtone:ratio
198
List Mode Settings
199
Source:gprf:gen<I>:Arb:file
199
Source:gprf:gen<I>:Dtone:level<Source
199
Source:gprf:gen<I>:List
199
Source:gprf:gen<I>:List:cindex
200
Source:gprf:gen<I>:List:count
200
Source:gprf:gen<I>:List:mode
200
Source:gprf:gen<I>:List:sstop
200
Source:gprf:gen<I>:List:dtime
201
Source:gprf:gen<I>:List:frequency
201
Source:gprf:gen<I>:List:rflevel
201
Power Measurement Commands
202
Source:gprf:gen<I>:List:dgain
202
Command Groups (Power Measurement)
203
Measurement Control and States
204
Measurement Control Parameters
206
Filter Settings
207
Statistical Settings
207
Trigger Settings
208
List Configuration
210
Measurement Results
212
External Power Sensor Measurement Commands
213
Command Groups (External Power Sensor Measurement)
214
Abort:gprf:meas<I>:Epsensor
215
Fetch:gprf:meas<I>:Epsensor:state
215
Initiate:gprf:meas<I>:Epsensor
215
Measurement Control and States
215
Stop:gprf:meas<I>:Epsensor
215
Fetch:gprf:meas<I>:Epsensor:state:all
216
Calibration:gprf:meas<I>:Epsensor:zero
217
Configure:gprf:meas<I>:Epsensor:repetition
217
Configure:gprf:meas<I>:Epsensor:scount
217
Statistical Settings
217
Zeroing
217
Configure:gprf:meas<I>:Epsensor:resolution
218
Sensor Configuration
218
Alphabetical List of Commands (GPRF)
219
Measurement Results
219
GSM Applications
222
GSM Multi Evaluation Measurement
222
GSM TX Measurements
222
How to Measure a UL GSM Signal
222
Test Setup
222
Configuring the Spectrum Measurement
223
Defining the Scope of the Measurement
223
GSM Multi Evaluation: Results
224
Speed Considerations
224
Trigger Settings
224
Conformance Requirements and Limit Settings
229
Detecting GSM Multislot Frames
239
Capturing GSM Burst Sequences
240
GSM GUI Reference
243
GSM Multi Evaluation: Parameters and Settings
244
Measurement Control
244
Signal Routing and Analyzer Settings
244
GSM Multi Evaluation Configuration: Measurement Control
246
GSM Multi Evaluation Configuration: Trigger
253
GSM Multi Evaluation Configuration: Limits
255
GSM Multi Evaluation Configuration: Display
258
GSM Multi Evaluation Configuration: Filter
258
Measurement Results
259
GSM Programming
261
Key Features
261
Programming the Multi Evaluation Measurement
261
Specifying General Measurement Settings
262
Specifying Measurement-Specific Settings
262
Performing Single Shot Measurements
263
Single Shot and Continuous Measurements
263
Configuring a Spectrum Measurement
264
Selecting Specific Burst Types
265
Command Groups (General Measurement Settings)
266
General Measurement Settings
266
GSM Command Reference
266
Signal Routing
266
Analyzer Settings
267
GSM Multi Evaluation Measurement Commands
268
Command Groups (Multi Evaluation)
270
Gsm Applications
271
Measurement Control and States
274
Enabling Results and Views
276
Statistical Settings
277
Measurement Settings
280
Trigger Settings
281
Configure:gsm:meas<I>:Mevaluation:trigger:delay
282
Configure:gsm:meas<I>:Mevaluation:trigger:threshold
282
Configure:gsm:meas<I>:Mevaluation:amode
283
Configure:gsm:meas<I>:Mevaluation:apattern
283
Configure:gsm:meas<I>:Mevaluation:glength
283
Configure:gsm:meas<I>:Mevaluation:trigger:tout
283
Configure:gsm:meas<I>:Mevaluation:rpmode
284
Configure:gsm:meas<I>:Mevaluation:smodulation:foffsets
284
Power Vs. Time Settings
284
Spectrum Modulation Settings
284
Configure:gsm:meas<I>:Mevaluation:smodulation:earea
285
Configure:gsm:meas<I>:Mevaluation:smodulation:tdfselect
286
Configure:gsm:meas<I>:Mevaluation:sswitching:foffsets
286
Spectrum Switching Settings
286
Configure:gsm:meas<I>:Mevaluation:sswitching:phmode
287
Configure:gsm:meas<I>:Mevaluation:sswitching:tdfselect
287
Limits (GMSK Modulation)
287
Configure:gsm:meas<I>:Mevaluation:limit:gmsk:evmagnitude
288
Configure:gsm:meas<I>:Mevaluation:limit:gmsk:merror
288
Configure:gsm:meas<I>:Mevaluation:limit:gmsk:iqoffset
289
Configure:gsm:meas<I>:Mevaluation:limit:gmsk:perror
289
Configure:gsm:meas<I>:Mevaluation:limit:gmsk:ferror
290
Configure:gsm:meas<I>:Mevaluation:limit:gmsk:iqimbalance
290
Configure:gsm:meas<I>:Mevaluation:limit:gmsk:terror
290
Configure:gsm:meas<I>:Mevaluation:limit:epsk:evmagnitude
291
Configure:gsm:meas<I>:Mevaluation:limit:epsk:merror
291
Limits (8PSK Modulation)
291
Configure:gsm:meas<I>:Mevaluation:limit:epsk:iqoffset
292
Configure:gsm:meas<I>:Mevaluation:limit:epsk:perror
292
Configure:gsm:meas<I>:Mevaluation:limit:epsk:ferror
293
Configure:gsm:meas<I>:Mevaluation:limit:epsk:iqimbalance
293
Configure:gsm:meas<I>:Mevaluation:limit:epsk:terror
293
Configure:gsm:meas<I>:Mevaluation:limit:pvtime:abpower<Number
294
Limits (Power Vs. Time)
294
Configure:gsm:meas<I>:Mevaluation:limit:gmsk:pvtime:upper:redge<Number>:Static
295
Configure:gsm:meas<I>:Mevaluation:limit:gmsk:pvtime:upper:upart<Number>:Static
295
Configure:gsm:meas<I>:Mevaluation:limit:pvtime:gplevel
295
Configure:gsm:meas<I>:Mevaluation:limit:gmsk:smodulation:rpower
298
Limits (Spectrum Modulation)
298
Configure:gsm:meas<I>:Mevaluation:limit:gmsk:smodulation:mpoint<Offset
299
Configure:gsm:meas<I>:Mevaluation:limit:epsk:smodulation:mpoint<Offset
300
Configure:gsm:meas<I>:Mevaluation:limit:epsk:smodulation:rpower
300
Configure:gsm:meas<I>:Mevaluation:limit:gmsk:sswitching:plevel
301
Limits (Spectrum Switching)
301
Configure:gsm:meas<I>:Mevaluation:limit:epsk:sswitching:plevel
302
Configure:gsm:meas<I>:Mevaluation:limit:gmsk:sswitching:mpoint<Offsetno
302
Configure:gsm:meas<I>:Mevaluation:limit:epsk:sswitching:mpoint<Offsetno
303
Configure:gsm:meas<I>:Mevaluation:pvtime:filter
304
EVM Measurement Results (Trace)
304
Fetch:gsm:meas<I>:Mevaluation:trace:evmagnitude:average
304
Fetch:gsm:meas<I>:Mevaluation:trace:evmagnitude:current
304
Fetch:gsm:meas<I>:Mevaluation:trace:evmagnitude:maximum
304
Filter Settings
304
Read:gsm:meas<I>:Mevaluation:trace:evmagnitude:average
304
Read:gsm:meas<I>:Mevaluation:trace:evmagnitude:current
304
Read:gsm:meas<I>:Mevaluation:trace:evmagnitude:maximum
304
EVM Measurement Results (Single Values)
305
Fetch:gsm:meas<I>:Mevaluation:evmagnitude
305
Magnitude Error Measurement Results (Trace)
305
Read:gsm:meas<I>:Mevaluation:evmagnitude
305
Fetch:gsm:meas<I>:Mevaluation:merror
306
Fetch:gsm:meas<I>:Mevaluation:trace:merror:average
306
Fetch:gsm:meas<I>:Mevaluation:trace:merror:current
306
Fetch:gsm:meas<I>:Mevaluation:trace:merror:maximum
306
Magnitude Error Measurement Results (Single Values)
306
Read:gsm:meas<I>:Mevaluation:merror
306
Read:gsm:meas<I>:Mevaluation:trace:merror:average
306
Read:gsm:meas<I>:Mevaluation:trace:merror:current
306
Read:gsm:meas<I>:Mevaluation:trace:merror:maximum
306
Fetch:gsm:meas<I>:Mevaluation:trace:perror:average
307
Fetch:gsm:meas<I>:Mevaluation:trace:perror:current
307
Fetch:gsm:meas<I>:Mevaluation:trace:perror:maximum
307
Phase Error Measurement Results (Trace)
307
Read:gsm:meas<I>:Mevaluation:trace:perror:average
307
Read:gsm:meas<I>:Mevaluation:trace:perror:current
307
Read:gsm:meas<I>:Mevaluation:trace:perror:maximum
307
Fetch:gsm:meas<I>:Mevaluation:perror
308
Phase Error Measurement Results (Single Values)
308
Read:gsm:meas<I>:Mevaluation:perror
308
Fetch:gsm:meas<I>:Mevaluation:trace:pvtime:average
309
Fetch:gsm:meas<I>:Mevaluation:trace:pvtime:current
309
Fetch:gsm:meas<I>:Mevaluation:trace:pvtime:maximum
309
Fetch:gsm:meas<I>:Mevaluation:trace:pvtime:minimum
309
Power Vs Time Measurement Results (Single Values)
309
Power Vs Time Measurement Results (Trace)
309
Read:gsm:meas<I>:Mevaluation:trace:pvtime:average
309
Read:gsm:meas<I>:Mevaluation:trace:pvtime:maximum
309
Read:gsm:meas<I>:Mevaluation:trace:pvtime:minimum
309
Fetch:gsm:meas<I>:Mevaluation:pvtime
310
Fetch:gsm:meas<I>:Mevaluation:trace:smodulation:frequency
310
Read:gsm:meas<I>:Mevaluation:pvtime
310
Read:gsm:meas<I>:Mevaluation:trace:smodulation:frequency
310
Spectrum Modulation Measurement Results
310
Fetch:gsm:meas<I>:Mevaluation:smodulation
311
Read:gsm:meas<I>:Mevaluation:smodulation
311
Spectrum Switching Measurement Results
311
Fetch:gsm:meas<I>:Mevaluation:sswitching
312
Fetch:gsm:meas<I>:Mevaluation:trace:sswitching:frequency
312
Read:gsm:meas<I>:Mevaluation:sswitching
312
Read:gsm:meas<I>:Mevaluation:trace:sswitching:frequency
312
Fetch:gsm:meas<I>:Mevaluation:terror
313
Independent Measurement Results (Single Values)
313
Measurement Results (Single Values Overview)
315
Alphabetical List of Commands (GSM)
318
Test Setup
322
WCDMA Applications
322
WCDMA Multi Evaluation Measurement
322
WCDMA TX Measurements
322
Defining the Scope of the Measurement
323
How to Measure an Uplink WCDMA Signal
323
Trigger Modes
324
WCDMA Multi Evaluation: Results
324
Conformance Requirements and Limit Settings
331
WCDMA GUI Reference
334
WCDMA Multi Evaluation: Parameters and Settings
334
Measurement Control
335
Signal Routing and Analyzer Settings
335
UE Signal Info
337
Multi Evaluation Settings
338
WCDMA Multi Evaluation Configuration: Trigger
341
Limits
342
WCDMA Multi Evaluation: Results
343
WCDMA Programming
344
Key Features
345
Programming the WCDMA Multi Evaluation Measurement
345
Specifying General Measurement Settings
345
Specifying Additional Measurement-Specific Settings
346
Specifying Required Settings
346
Configuring the Trigger System
347
Specifying Limits
347
Performing Single Shot Measurements
348
Single Shot and Continuous Measurements
349
General Measurement Settings
350
WCDMA Command Reference
350
Command Groups (General Measurement Settings)
351
Analyzer Settings
351
Configure:wcdma:meas<I>:Rfsettings:enpower
351
Configure:wcdma:meas<I>:Rfsettings:umargin
351
Configure:wcdma:meas<I>:Rfsettings:eattenuation
352
Configure:wcdma:meas<I>:Rfsettings:frequency
352
Signal Routing
352
Configure:wcdma:meas<I>:Uesignal:achannels
353
Configure:wcdma:meas<I>:Uesignal:dpdch
353
Configure:wcdma:meas<I>:Uesignal:scode
353
Configure:wcdma:meas<I>:Uesignal:sformat
353
UE Signal Info
353
WCDMA Multi Evaluation Measurement Commands
354
Command Groups (Multi Evaluation)
355
Wcdma Applications
356
Measurement Control and States
359
Measurement Parameters
361
Configure:wcdma:meas<I>:Mevaluation:amode:modulation
363
Configure:wcdma:meas<I>:Mevaluation:dmode:modulation
363
Configure:wcdma:meas<I>:Mevaluation:scount:modulation
363
Statistical Settings (Modulation)
363
Configure:wcdma:meas<I>:Mevaluation:cdthreshold:modulation
364
Configure:wcdma:meas<I>:Mevaluation:scount:spectrum
364
Configure:wcdma:meas<I>:Mevaluation:sscalar:modulation
364
Statistical Settings (Spectrum)
364
Configure:wcdma:meas<I>:Mevaluation:limit:merror
365
Configure:wcdma:meas<I>:Trigger:source
365
Configure:wcdma:meas<I>:Trigger:tout
365
Limits (Modulation)
365
Trigger Settings
365
Configure:wcdma:meas<I>:Mevaluation:limit:evmagnitude
366
Configure:wcdma:meas<I>:Mevaluation:limit:perror
366
Configure:wcdma:meas<I>:Mevaluation:limit:cferror
367
Configure:wcdma:meas<I>:Mevaluation:limit:iqimbalance
367
Configure:wcdma:meas<I>:Mevaluation:limit:iqoffset
367
Configure:wcdma:meas<I>:Mevaluation:limit:aclr:absolute
368
Configure:wcdma:meas<I>:Mevaluation:limit:aclr:relative
368
Configure:wcdma:meas<I>:Mevaluation:limit:emask:absolute
368
Limits (Spectrum)
368
Configure:wcdma:meas<I>:Mevaluation:limit:emask:relative
369
EVM Measurement Results (Traces)
369
Fetch:wcdma:meas<I>:Mevaluation:trace:evmagnitude:rms:current
369
Fetch:wcdma:meas<I>:Mevaluation:trace:evmagnitude:rms:average
370
Fetch:wcdma:meas<I>:Mevaluation:trace:evmagnitude:rms:maximum
370
Fetch:wcdma:meas<I>:Mevaluation:trace:evmagnitude:rms:sdeviation
370
Read:wcdma:meas<I>:Mevaluation:trace:evmagnitude:rms:average
370
Read:wcdma:meas<I>:Mevaluation:trace:evmagnitude:rms:current
370
Read:wcdma:meas<I>:Mevaluation:trace:evmagnitude:rms:maximum
370
Read:wcdma:meas<I>:Mevaluation:trace:evmagnitude:rms:sdeviation
370
Fetch:wcdma:meas<I>:Mevaluation:trace:evmagnitude:peak:average
371
Fetch:wcdma:meas<I>:Mevaluation:trace:evmagnitude:peak:current
371
Fetch:wcdma:meas<I>:Mevaluation:trace:evmagnitude:peak:maximum
371
Fetch:wcdma:meas<I>:Mevaluation:trace:evmagnitude:peak:sdeviation
371
Read:wcdma:meas<I>:Mevaluation:trace:evmagnitude:peak:average
371
Read:wcdma:meas<I>:Mevaluation:trace:evmagnitude:peak:current
371
Read:wcdma:meas<I>:Mevaluation:trace:evmagnitude:peak:maximum
371
Read:wcdma:meas<I>:Mevaluation:trace:evmagnitude:peak:sdeviation
371
Fetch:wcdma:meas<I>:Mevaluation:trace:merror:rms:average
372
Fetch:wcdma:meas<I>:Mevaluation:trace:merror:rms:current
372
Fetch:wcdma:meas<I>:Mevaluation:trace:merror:rms:maximum
372
Fetch:wcdma:meas<I>:Mevaluation:trace:merror:rms:sdeviation
372
Magnitude Error Measurement Results (Traces)
372
Read:wcdma:meas<I>:Mevaluation:trace:merror:rms:average
372
Read:wcdma:meas<I>:Mevaluation:trace:merror:rms:current
372
Read:wcdma:meas<I>:Mevaluation:trace:merror:rms:maximum
372
Read:wcdma:meas<I>:Mevaluation:trace:merror:rms:sdeviation
372
Fetch:wcdma:meas<I>:Mevaluation:trace:merror:peak:average
373
Fetch:wcdma:meas<I>:Mevaluation:trace:merror:peak:current
373
Fetch:wcdma:meas<I>:Mevaluation:trace:merror:peak:maximum
373
Fetch:wcdma:meas<I>:Mevaluation:trace:merror:peak:sdeviation
373
Read:wcdma:meas<I>:Mevaluation:trace:merror:peak:average
373
Read:wcdma:meas<I>:Mevaluation:trace:merror:peak:current
373
Read:wcdma:meas<I>:Mevaluation:trace:merror:peak:maximum
373
Read:wcdma:meas<I>:Mevaluation:trace:merror:peak:sdeviation
373
Fetch:wcdma:meas<I>:Mevaluation:trace:perror:rms:average
374
Fetch:wcdma:meas<I>:Mevaluation:trace:perror:rms:current
374
Fetch:wcdma:meas<I>:Mevaluation:trace:perror:rms:maximum
374
Phase Error Measurement Results (Traces)
374
Read:wcdma:meas<I>:Mevaluation:trace:perror:rms:average
374
Read:wcdma:meas<I>:Mevaluation:trace:perror:rms:current
374
Read:wcdma:meas<I>:Mevaluation:trace:perror:rms:maximum
374
Fetch:wcdma:meas<I>:Mevaluation:trace:perror:peak:average
375
Fetch:wcdma:meas<I>:Mevaluation:trace:perror:peak:current
375
Fetch:wcdma:meas<I>:Mevaluation:trace:perror:peak:maximum
375
Fetch:wcdma:meas<I>:Mevaluation:trace:perror:rms:sdeviation
375
Read:wcdma:meas<I>:Mevaluation:trace:perror:peak:average
375
Read:wcdma:meas<I>:Mevaluation:trace:perror:peak:current
375
Read:wcdma:meas<I>:Mevaluation:trace:perror:peak:maximum
375
Read:wcdma:meas<I>:Mevaluation:trace:perror:rms:sdeviation
375
Fetch:wcdma:meas<I>:Mevaluation:trace:emask:mfleft:average
376
Fetch:wcdma:meas<I>:Mevaluation:trace:emask:mfleft:current
376
Fetch:wcdma:meas<I>:Mevaluation:trace:emask:mfleft:maximum
376
Fetch:wcdma:meas<I>:Mevaluation:trace:emask:mfright:average
376
Fetch:wcdma:meas<I>:Mevaluation:trace:emask:mfright:current
376
Fetch:wcdma:meas<I>:Mevaluation:trace:emask:mfright:maximum
376
Fetch:wcdma:meas<I>:Mevaluation:trace:perror:peak:sdeviation
376
Read:wcdma:meas<I>:Mevaluation:trace:emask:mfleft:current
376
Read:wcdma:meas<I>:Mevaluation:trace:perror:peak:sdeviation
376
Spectrum Emission Measurement Results (Traces)
376
CDP Vs Slot Measurement Results (Traces)
377
Spectrum Measurement Results
379
Fetch:wcdma:meas<I>:Mevaluation:modulation:maximum
380
Measurement Results (Single Values)
380
Read:wcdma:meas<I>:Mevaluation:modulation:current
380
Read:wcdma:meas<I>:Mevaluation:modulation:maximum
380
Fetch:wcdma:meas<I>:Mevaluation:modulation:average
381
Read:wcdma:meas<I>:Mevaluation:modulation:average
381
Fetch:wcdma:meas<I>:Mevaluation:modulation:sdeviation
382
Read:wcdma:meas<I>:Mevaluation:modulation:sdeviation
382
CDP Vs Slot Measurement Results (Single Values)
383
Fetch:wcdma:meas<I>:Mevaluation:cdp:average
383
Fetch:wcdma:meas<I>:Mevaluation:cdp:current
383
Fetch:wcdma:meas<I>:Mevaluation:cdp:maximum
383
Fetch:wcdma:meas<I>:Mevaluation:cdp:minimum
383
Read:wcdma:meas<I>:Mevaluation:cdp:average
383
Read:wcdma:meas<I>:Mevaluation:cdp:current
383
Read:wcdma:meas<I>:Mevaluation:cdp:maximum
383
Read:wcdma:meas<I>:Mevaluation:cdp:minimum
383
Alphabetical List of Commands (WCDMA)
384
Fetch:wcdma:meas<I>:Mevaluation:cdp:sdeviation
384
Read:wcdma:meas<I>:Mevaluation:cdp:sdeviation
384
Test Setup
389
Wimax Applications
389
Wimax Multi Evaluation Measurement
389
Wimax TX Measurements
389
Frame Settings and Burst Selection
390
How to Measure an UL OFDMA Signal
390
Measurement Results
392
Signal Processing
392
Wimax GUI Reference
396
Wimax Multi Evaluation: Parameters and Settings
396
Measurement Control
397
Signal Routing and Analyzer Settings
397
Multi Evaluation Configuration: Control
398
Multi Evaluation Configuration: Measurement Parameters
399
Multi Evaluation Configuration: Map of Bursts
401
Multi Evaluation Configuration: Zone Definition
401
Multi Evaluation Configuration: Trigger Settings
402
Wimax Multi Evaluation: Results
403
Analyzer Settings
408
Command Groups (General Measurement Settings)
408
General Measurement Settings
408
Wimax Command Reference
408
Signal Routing
409
Wimax Multi Evaluation Measurement Commands
410
Command Groups (Multi Evaluation)
411
Measurement Control and States
415
Statistical Settings
416
Measurement Parameters
417
Zone Definition
418
Map of Bursts
419
Trigger Settings
420
Measurement Results (EVM)
421
Measurement Results (I/Q Offset, Gain Imbalance, Quadrature Mismatch)
423
Measurement Results (Center Frequency Error, Burst Power, Crest Factor, CINR)
424
Measurement Results (Spectral Flatness)
426
Alphabetical List of Commands (Wimax)
428
Annexes
433
Interfaces and Connectors
433
Lan Remote
433
Rear Panel Connectors
433
Usb
433
DVI (Option R&S CMW-B620A)
434
LAN Interface
434
Ref In, Ref out 1
434
Trig A, Trig B
434
Protocol
435
GPIB Bus Interface
437
Interface Functions
438
Interface Messages
439
Comparison with R&S CMU
440
Instrument Messages
440
RF Path Settings
441
Segmentation, Addressing and Resource Management
441
Generator Control
442
Measurement Control
442
Index
444
Advertisement
Advertisement
Related Products
Rohde & Schwarz CMW500 Series
Rohde & Schwarz R&S CMW-KM2 Series
Rohde & Schwarz R&S CMW-KG200
Rohde & Schwarz CMW-KM8 Series
Rohde & Schwarz CMW-KS8 Series
Rohde & Schwarz CMW-KM800
Rohde & Schwarz CMW-KS881
Rohde & Schwarz CMW-KE800
Rohde & Schwarz R&S CMW-KM700
Rohde & Schwarz R&S CMW-KS2 Series
Rohde & Schwarz Categories
Measuring Instruments
Test Equipment
Portable Generator
Power Supply
Accessories
More Rohde & Schwarz Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL